A comparison of the use of Trachlight® and Eschmann multiple‐use introducer in simulated difficult intubation

Background and objective: The Eschmann multiple‐use introducer is widely used in the management of difficult intubations. Transillumination of the neck is less commonly used. We conducted a randomized crossover study comparing the Trachlight® lightwand and Eschmann multiple‐use introducer in simulated difficult intubation. Methods: Sixty‐four healthy patients were studied using a standard anaesthetic and full muscle relaxation assessed by train of four. A Macintosh laryngoscope was then inserted and then lowered to simulate a Grade 3 view. Tracheal placement was attempted with both Trachlight® lightwand and Eschmann multiple‐use introducer in a randomized order. Anaesthetists placing the devices had extensive experience with the Eschmann multiple‐use introducer, but only 15 previous uses of the Trachlight®. Success rates and time for tracheal placement were recorded. Results: The Eschmann multiple‐use introducer and Trachlight® were successfully placed in 96.8% and 93.7%, respectively (n.s.). Mean (SD) time to intubation for Eschmann multiple‐use introducer and Trachlight® were 15(6) and *21(13), respectively (*P < 0.001). Conclusion: The Trachlight® is a potentially useful alternative to the Eschmann multiple‐use introducer in difficult intubation.

[1]  S. Kiyama,et al.  Equipment list for difficult airway management , 2004, Anaesthesia.

[2]  W. Mapleson,et al.  Evaluation of Frova, single‐use intubation introducer, in a manikin. Comparison with Eschmann multiple‐use introducer and Portex single‐use introducer * , 2004, Anaesthesia.

[3]  J. Pandit,et al.  Use of the bougie in simulated difficult intubation. 2. Comparison of single‐use bougie with multiple‐use bougie * , 2003, Anaesthesia.

[4]  A. Wilkes,et al.  To shape or not to shape…Simulated bougie‐assisted difficult intubation in a manikin * , 2003, Anaesthesia.

[5]  A. Shigematsu,et al.  The gum elastic bougie eases tracheal intubation while applying cricoid pressure compared to a stylet , 2003, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[6]  J. Brimacombe,et al.  Hemodynamic Responses Among Three Tracheal Intubation Devices in Normotensive and Hypertensive Patients , 2003, Anesthesia and analgesia.

[7]  J. Henderson,et al.  Bougie trauma--what trauma? , 2003, Anaesthesia.

[8]  A R Wilkes,et al.  A comparison of simulated difficult intubation with multiple‐use and single‐use bougies in a manikin * , 2003, Anaesthesia.

[9]  Shinji Takahashi,et al.  Hemodynamic Responses to Tracheal Intubation with Laryngoscope Versus Lightwand Intubating Device (Trachlight®) in Adults with Normal Airway , 2002, Anesthesia and analgesia.

[10]  Shinji Takahashi,et al.  Hemodynamic Responses to Tracheal Intubation with Laryngoscope Versus Lightwand Intubating Device (Trachlight®) in Adults with Normal Airway , 2002, Anesthesia and analgesia.

[11]  A. Ho,et al.  On predicting difficult intubation , 2002, Anaesthesia.

[12]  F. Agrò,et al.  Efficacy of a combined technique using the Trachlight™ together with direct laryngoscopy under simulated difficult airway conditions in 350 anesthetized patients , 2002, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[13]  M. Stacey,et al.  Survey of the use of the gum elastic bougie in clinical practice. , 2002, Anaesthesia.

[14]  D. H. Graham Lightwand intubation using the Trachlight: a brief review of current knowledge , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[15]  A. Pearce,et al.  Presence of protein deposits on 'cleaned' re-usable anaesthetic equipment. , 2001, Anaesthesia.

[16]  T. Cook,et al.  Rapid sequence induction: a national survey of practice , 2001, Anaesthesia.

[17]  F. Agrò,et al.  Lightwand intubation using the Trachlight™: a brief review of current knowledge , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[18]  K. Zuma,et al.  Effect of Cricoid Pressure on the Success of Endotracheal Intubation with a Lightwand , 2001, Anesthesiology.

[19]  M. Clancy,et al.  Difficult airway equipment in English emergency departments , 2000, Anaesthesia.

[20]  K. Omote,et al.  A Comparison of Hemodynamic Changes After Endotracheal Intubation by Using the Lightwand Device and the Laryngoscope in Normotensive and Hypertensive Patients , 2000, Anesthesia and analgesia.

[21]  J. M. Cupitt Microbial contamination of gum elastic bougies , 2000, Anaesthesia.

[22]  T. Cook A new practical classification of laryngeal view , 2000, Anaesthesia.

[23]  M. Popat,et al.  Pharyngeal wall perforation — an unusual complication of blind intubation with a gum elastic bougic , 1999, Anaesthesia.

[24]  S. Yentis,et al.  Evaluation of an improved scoring system for the grading of direct laryngoscopy , 1998, Anaesthesia.

[25]  K. Hanaoka,et al.  Safety of a New Lightwand Device (Trachlight[trade mark sign]): Temperature and Histopathological Study , 1998, Anesthesia and analgesia.

[26]  W. Rosenblatt,et al.  Practice patterns in managing the difficult airway by anesthesiologists in the United States. , 1998 .

[27]  W. Rosenblatt,et al.  Practice Patterns in Managing the Difficult Airway by Anesthesiologists in the United States , 1998, Anesthesia and analgesia.

[28]  R. Vaughan,et al.  Simulated difficult intubation , 1996, Anaesthesia.

[29]  D. Rose,et al.  The incidence of airway problems depends on the definition used , 1996, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[30]  O. Hung,et al.  Clinical Trial of a New Lightwand Device (Trachlight) to Intubate the Trachea , 1995, Anesthesiology.

[31]  O. Hung,et al.  Lightwand intubation: II — Clinical trial of a new lightwand for tracheal intubation in patients with difficult airways , 1995, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[32]  O. Hung,et al.  Lightwand intubation: I — A new lightwand device , 1995, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[33]  D. Rose,et al.  The airway: problems and predictions in 18,500 patients , 1994, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[34]  J. Nolan,et al.  An evaluation of the gum elastic bougie , 1992, Anaesthesia.

[35]  S. Dogra,et al.  Increased use of gum‐elastic bougie in clinical practice , 1990, Anaesthesia.

[36]  T. Howells,et al.  Transilluminated tracheal intubation. , 1989, British journal of anaesthesia.

[37]  I. P. Latto,et al.  Successful difficult intubation , 1988, Anaesthesia.

[38]  W. Sellers,et al.  Difficult tracheal intubation , 1987 .

[39]  R. Kaplan,et al.  Success rates of blind orotracheal intubation using a transillumination technique with a lighted stylet. , 1986, Annals of emergency medicine.

[40]  C. Bell,et al.  Atracurium and McArdle's disease , 1986, Anaesthesia.

[41]  L. Gemmell,et al.  Association of Anaesthetists of Great Britain and Ireland , 1984 .