Explosives detection in soil using a field-portable continuous flow immunosensor.

A field method for quantitative analysis of explosives in contaminated soil samples is described. The method is based on a displacement immunoassay performed in a commercial instrument, the FAST 2000, engineered by Research International Inc. The method can be used on-site to measure 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) within 5min. For this study, replicate analyses were performed on soil extracts prepared from each field sample as well as appropriate controls, blanks, and laboratory standards. Statistical analyses were done to assess accuracy, bias, and predictability of the method. The results demonstrated that the immunosensor could be used effectively to screen environmental samples for the presence or absence of explosives. In most samples, the method also provided quantitative values that were in good agreement with standard laboratory analyses using HPLC. A limited number of sample matrices interfered with the immunoassay and produced results that varied significantly from the laboratory data. In each case, the compounds causing the problem have been identified and efforts are being made to minimize these matrix interferences in future field evaluations.

[1]  David W. Conrad,et al.  Detection of TNT in Water Using an Evanescent Wave Fiber-Optic Biosensor , 1995 .

[2]  J.M.F. Douse,et al.  Trace analysis of explosives in handswab extracts using Amberlite XAD-7 porous polymer beads, silica capillary column gas chromatography with electron-capture detection and thin-layer chromatography , 1982 .

[3]  J. W. Huber,et al.  Technical note: on-line supercritical sample-preparation accessory for chromatography , 1988 .

[4]  W. Rudolf Seitz,et al.  Single fiber absorption measurements for remote detection of 2,4,6-trinitrotoluene , 1989 .

[5]  R. Niessner,et al.  Rapid field screening test for determination of 2,4,6-trinitrotoluene in water and soil with immunofiltration , 1994 .

[6]  Reinhard Niessner,et al.  Enzyme-Linked Immunosorbent Assay for the Determination of 2,4,6-Trinitrotoluene and Related Nitroaromatic Compounds , 1992 .

[7]  S A Oehrle Analysis of nitramine and nitroaromatic explosives in pink water by capillar electrophoresis , 1997, Electrophoresis.

[8]  Frances S. Ligler,et al.  Capillary-Based Displacement Flow Immunosensor , 1997 .

[9]  H. Craig,et al.  Federal Facilities Forum Issue Field Sampling And Selecting On-site Analytical Methods For Explosives In Water , 1999 .

[10]  William A. MacCrehan,et al.  Separation and identification of organic gunshot and explosive constituents by micellar electrokinetic capillary electrophoresis , 1991 .

[11]  M. Walsh,et al.  Development of field screening methods for TNT, 2,4-DNT and RDX in soil. , 1992, Talanta.

[12]  Reinhard Bredehorst,et al.  Continuous-flow immunosensor for detection of explosives , 1993 .

[13]  Thomas F. Jenkins,et al.  Field sampling and selecting on-site analytical methods for explosives in soil , 1996 .

[14]  K. Cammann,et al.  Determination of explosives residues in soils by micellar electrokinetic capillary chromatography and high­ performance liquid chromatography A comparative study , 1993 .

[15]  Ann B. Strong,et al.  Comparison of solid phase extraction with salting-out solvent extraction for preconcentration of nitroaromatic and nitramine explosives from water , 1994 .

[16]  P. Kolla,et al.  Gas chromatography, liquid chromatography and ion chromatography adapted to the trace analysis of explosives , 1994 .

[17]  Reinhard Niessner,et al.  Characterization of a monoclonal TNT-antibody by measurement of the cross-reactivities of nitroaromatic compounds , 1999 .

[19]  R. Spalding,et al.  Groundwater munition residues and nitrate near Grand Island, Nebraska, U.S.A. , 1988 .

[20]  Y. Hirata,et al.  Supercritical fluid extraction combined with microcolumn liquid chromatography for the analysis of polymer additives , 1989 .

[21]  Frances S. Ligler,et al.  On-site detection of TNT with a portable fiber optic biosensor , 1997 .

[22]  W. Griest,et al.  Determination of Explosives and Some Metabolites of TNT in Biological and Environmental Samples by Liquid Chromatography on a Mixed-Mode C18-anion Column , 1996 .

[23]  Upvan Narang,et al.  A displacement flow immunosensor for explosive detection using microcapillaries , 1997 .