Real‐time monitoring and control of the load phase of a protein A capture step

The load phase in preparative Protein A capture steps is commonly not controlled in real‐time. The load volume is generally based on an offline quantification of the monoclonal antibody (mAb) prior to loading and on a conservative column capacity determined by resin‐life time studies. While this results in a reduced productivity in batch mode, the bottleneck of suitable real‐time analytics has to be overcome in order to enable continuous mAb purification. In this study, Partial Least Squares Regression (PLS) modeling on UV/Vis absorption spectra was applied to quantify mAb in the effluent of a Protein A capture step during the load phase. A PLS model based on several breakthrough curves with variable mAb titers in the HCCF was successfully calibrated. The PLS model predicted the mAb concentrations in the effluent of a validation experiment with a root mean square error (RMSE) of 0.06 mg/mL. The information was applied to automatically terminate the load phase, when a product breakthrough of 1.5 mg/mL was reached. In a second part of the study, the sensitivity of the method was further increased by only considering small mAb concentrations in the calibration and by subtracting an impurity background signal. The resulting PLS model exhibited a RMSE of prediction of 0.01 mg/mL and was successfully applied to terminate the load phase, when a product breakthrough of 0.15 mg/mL was achieved. The proposed method has hence potential for the real‐time monitoring and control of capture steps at large scale production. This might enhance the resin capacity utilization, eliminate time‐consuming offline analytics, and contribute to the realization of continuous processing. Biotechnol. Bioeng. 2017;114: 368–373. © 2016 The Authors. Biotechnology and Bioengineering published by Wiley Periodicals, Inc.

[1]  Jürgen Hubbuch,et al.  Advances in inline quantification of co‐eluting proteins in chromatography: Process‐data‐based model calibration and application towards real‐life separation issues , 2015, Biotechnology and bioengineering.

[2]  A. Höskuldsson PLS regression methods , 1988 .

[3]  M. N. Gupta Methods for Affinity-Based Separations of Enzymes and Proteins , 2002, Methods and Tools in Biosciences and Medicine.

[4]  M. Forina,et al.  Multivariate calibration. , 2007, Journal of chromatography. A.

[5]  Massimo Morbidelli,et al.  Twin-column CaptureSMB: a novel cyclic process for protein A affinity chromatography. , 2015, Journal of chromatography. A.

[6]  Brian Hubbard,et al.  Downstream processing of monoclonal antibodies--application of platform approaches. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[7]  David Robbins,et al.  A Novel Approach to Monitor Clearance of Host Cell Proteins Associated With Monoclonal Antibodies , 2014, Biotechnology progress.

[8]  S. Honda,et al.  Engineered protein A ligands, derived from a histidine-scanning library, facilitate the affinity purification of IgG under mild acidic conditions , 2014, Journal of biological engineering.

[9]  H. Chase,et al.  Rapid chromatographic monitoring of bioprocesses. , 1986, Biosensors.

[10]  Massimo Morbidelli,et al.  Microarray-based MALDI-TOF mass spectrometry enables monitoring of monoclonal antibody production in batch and perfusion cell cultures. , 2016, Methods.

[11]  P. Hinckley,et al.  Host cell protein clearance during protein a chromatography: Development of an improved column wash step , 2008, Biotechnology progress.

[12]  F. Steindl,et al.  Comparison of protein A affinity sorbents III. Life time study. , 2006, Journal of chromatography. A.

[13]  Lars Järnström,et al.  Comparison of lignin derivatives as substrates for laccase-catalyzed scavenging of oxygen in coatings and films , 2014, Journal of biological engineering.

[14]  J. Hubbuch,et al.  A tool for selective inline quantification of co‐eluting proteins in chromatography using spectral analysis and partial least squares regression , 2014, Biotechnology and bioengineering.

[15]  R L Fahrner,et al.  Real-time control of antibody loading during protein A affinity chromatography using an on-line assay. , 1999, Journal of chromatography. A.

[16]  Aline Zimmer,et al.  Mid‐infrared spectroscopy‐based analysis of mammalian cell culture Parameters , 2015, Biotechnology progress.

[17]  S S Ozturk,et al.  Real‐time monitoring of protein secretion in mammalian cell fermentation: Measurement of monoclonal antibodies using a computer‐controlled HPLC system (BioCad/RPM) , 1995, Biotechnology and bioengineering.

[18]  F. Regnier,et al.  Automated process monitoring of monoclonal antibody production. , 1993, Analytical chemistry.

[19]  Daniel Cummings,et al.  Integrated continuous production of recombinant therapeutic proteins , 2012, Biotechnology and bioengineering.

[20]  Jing Liu,et al.  A mechanistic study of Protein A chromatography resin lifetime. , 2009, Journal of chromatography. A.

[21]  Daniel G Bracewell,et al.  Host cell protein adsorption characteristics during protein a chromatography , 2012, Biotechnology progress.

[22]  Abhinav A Shukla,et al.  Recent advances in large-scale production of monoclonal antibodies and related proteins. , 2010, Trends in biotechnology.

[23]  Margaret A. Nemeth,et al.  Multi- and Megavariate Data Analysis , 2003, Technometrics.