A two-level system-wide automatic voltage control system

A two-level system-wide AVC system based on optimal reactive power flow (ORPF) is proposed. The architecture of this two-level system-wide AVC system is different from the popular three-level hierarchical structure in that it is implemented centralized. One distinguished feature of the described AVC system is that it does not require the need of performing zone division and it can automatically adapt to structural changes in power systems. Another feature of the described AVC system is that it works even when the state estimation function of the underlying control center fails. To achieve a close-loop automatic voltage control, the two-level system-wide AVC system has two optimization-based voltage control modules: an optimal reactive power flow module and a corrective voltage control (CVC) module. At present, the proposed AVC system has been commissioned and put into a close-loop mode in four provincial power grids in China. The performance of the two-level system-wide AVC system has been very encouraging.

[1]  F.-R. Graf Real time application of an optimal power flow algorithm for reactive power allocation of the RWE energy control center , 1993 .

[2]  Wu Wenchuan Power Network Partitioning Based on Clustering Analysis in Mvar Control Space , 2005 .

[3]  Marija Ilic-Spong,et al.  Secondary voltage control using pilot point information , 1988 .

[4]  S. Corsi,et al.  The coordinated automatic voltage control of the Italian transmission Grid-part I: reasons of the choice and overview of the consolidated hierarchical system , 2004, IEEE Transactions on Power Systems.

[5]  J. Y. Leost,et al.  Survey of the Secondary Voltage Control in France : Present Realization and Investigations , 1987, IEEE Transactions on Power Systems.

[6]  Li Qin Study on Coordinated Secondary Voltage Control , 2005 .

[7]  Hongbin Sun,et al.  Study of system-wide Automatic Voltage Control on PJM system , 2010, IEEE PES General Meeting.

[8]  J. C. Sabonnadiere,et al.  Structural analysis of the electrical system , 1989 .

[9]  Tang Lei Coordination of Continuous Variables and Discrete Variables in Automatic Voltage Control Part Two Coordinated Voltage Control Among Power Plants and Substations , 2008 .

[10]  Hongbin Sun,et al.  Development and applications of system-wide automatic voltage control system in China , 2009, 2009 IEEE Power & Energy Society General Meeting.

[11]  G. Dell'Olio,et al.  The coordinated automatic voltage control of the Italian transmission Grid-part II: control apparatuses and field performance of the consolidated hierarchical system , 2004, IEEE Transactions on Power Systems.

[12]  J. C. Sabonnadiere,et al.  Structural Analysis of the Electrical System: Application to Secondary Voltage Control in France , 1989, IEEE Power Engineering Review.