2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series

BackgroundScrew fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series was the evaluation of screw misplacement rate and functional outcome of percutaneous screw fixation of pelvic ring disruptions using a 2D navigation system.MethodsBetween August 2004 and December 2007, 44 of 442 patients with pelvic injuries were included for closed reduction and percutaneous screw fixation of disrupted pelvic ring lesions using an optoelectronic 2D-fluoroscopic based navigation system. Operating and fluoroscopy time were measured, as well as peri- and postoperative complications documented. Screw position was assessed by postoperative CT scans. Quality of live was evaluated by SF 36-questionnaire in 40 of 44 patients at mean follow up 15.5 ± 1.2 month.Results56 iliosacral- and 29 ramus pubic-screws were inserted (mean operation time per screw 62 ± 4 minutes, mean fluoroscopy time per screw 123 ± 12 seconds). In post-operative CT-scans the screw position was assessed and graded as follows: I. secure positioning, completely in the cancellous bone (80%); II. secure positioning, but contacting cortical bone structures (14%); III. malplaced positioning, penetrating the cortical bone (6%). The malplacements predominantly occurred in bilateral overlapping screw fixation. No wound infection or iatrogenic neurovascular damage were observed. Four re-operations were performed, two of them due to implant-misplacement and two of them due to implant-failure.Conclusion2D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures, but in cases of a bilateral iliosacral screw fixation an increased risk for screw misplacement was observed. If additional ramus pubic screw fixations are performed, the retrograde inserted screws have to pass the iliopubic eminence to prevent an axial screw loosening.

[1]  Rick Sasso,et al.  An Evaluation of Image-Guided Technologies in the Placement of Percutaneous Iliosacral Screws , 2006, Spine.

[2]  P. Simonian,et al.  A rational approach to pelvic trauma. Resuscitation and early definitive stabilization. , 1995, Clinical orthopaedics and related research.

[3]  W. Steinbrich,et al.  Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation , 1997, CardioVascular and Interventional Radiology.

[4]  F. Mann,et al.  Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. , 1996, Journal of orthopaedic trauma.

[5]  Philip J. Kregor,et al.  Early Results of Percutaneous Iliosacral Screws Placed with the Patient in the Supine Position , 1995, Journal of orthopaedic trauma.

[6]  P. Simonian,et al.  Preliminary Report: The Retrograde Medullary Superior Pubic Ramus Screw for the Treatment of Anterior Pelvic Ring Disruptions: A New Technique , 1995, Journal of orthopaedic trauma.

[7]  W. Mills,et al.  Percutaneous fixation of pelvic ring disruptions. , 2000, Clinical orthopaedics and related research.

[8]  Robert W. Harris,et al.  Percutaneous Screw Fixation of Fractures of the Iliac Wing and Fracture-dislocations of the Sacro-iliac Joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess “Lateral Compression Type II” Pelvic Fractures) , 2002, Journal of orthopaedic trauma.

[9]  J. Shaw,et al.  Posterior stabilization of pelvic fractures by use of threaded compression rods. Case reports and mechanical testing. , 1985, Clinical orthopaedics and related research.

[10]  R M Smith,et al.  Fluoroscopy-Based Multiplanar Image Guidance for Insertion of Sacroiliac Screws , 2002, Clinical orthopaedics and related research.

[11]  J. Matta,et al.  Internal fixation of pelvic ring fractures. , 1989, Clinical orthopaedics and related research.

[12]  Florian Gebhard,et al.  Computer-Guidance in Percutaneous Screw Stabilization of the Iliosacral Joint , 2004, Clinical orthopaedics and related research.

[13]  W. Mills,et al.  Iliosacral screw fixation: early complications of the percutaneous technique. , 1997, Journal of orthopaedic trauma.

[14]  B. Moed,et al.  S2 Iliosacral Screw Fixation for Disruptions of the Posterior Pelvic Ring: A Report of 49 Cases , 2006, Journal of orthopaedic trauma.

[15]  S. A. Majeed External fixation of the injured pelvis. The functional outcome. , 1990, The Journal of bone and joint surgery. British volume.

[16]  Christian Krettek,et al.  Clinical applications--pelvis. , 2004, Injury.

[17]  D. Kahler Percutaneous Screw Insertion for Acetabular and Sacral Fractures , 2003 .

[18]  Paul Tornetta,et al.  Standard Multiplanar Fluoroscopy Versus a Fluoroscopically Based Navigation System for the Percutaneous Insertion of Iliosacral Screws: A Cadaver Model , 2005, Journal of orthopaedic trauma.

[19]  T. Scalea,et al.  Early open reduction and internal fixation of the disrupted pelvic ring. , 1986, The Journal of trauma.

[20]  M. Gardner,et al.  Percutaneous placement of iliosacral screws without electrodiagnostic monitoring. , 2009, The Journal of trauma.

[21]  Kevin Cederberg,et al.  Superior Pubic Ramus Fractures Fixed With Percutaneous Screws: What Predicts Fixation Failure? , 2008, Journal of orthopaedic trauma.

[22]  N P Haas,et al.  [Navigation assisted by image conversion. An experimental study on pelvic screw fixation]. , 2001, Der Unfallchirurg.

[23]  A. V. van Vugt,et al.  Fluoroscopic positioning of sacroiliac screws in 88 patients. , 2002, The Journal of trauma.

[24]  C. Jones,et al.  Superior gluteal artery injury during iliosacral screw placement. , 1999, Journal of orthopaedic trauma.

[25]  J. Chapman,et al.  Decompression and Lumbopelvic Fixation for Sacral Fracture-Dislocations With Spino-pelvic Dissociation , 2006, Journal of orthopaedic trauma.

[26]  N. Ebraheim,et al.  Percutaneous computed-tomography-stabilization of pelvic fractures: preliminary report. , 1987, Journal of orthopaedic trauma.

[27]  Y. Chi,et al.  [Percutaneous fixation of pelvic ring disruptions]. , 2006, Zhonghua wai ke za zhi [Chinese journal of surgery].

[28]  D. Krappinger,et al.  Stabilization of the posterior pelvic ring with a slide-insertion plate. , 2007, Operative Orthopadie und Traumatologie.

[29]  J Windolf,et al.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial]. , 2006, Der Unfallchirurg.

[30]  N. Schep,et al.  Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain. , 2004, The Journal of trauma.

[31]  J. Windolf,et al.  Computerassistierte Verschraubung des hinteren Beckenrings , 2006, Der Unfallchirurg.

[32]  L. P. Nolte,et al.  Bildwandler-gestützte Navigation Eine experimentelle Studie zu Beckenverschraubungen , 2001, Der Unfallchirurg.

[33]  E Schneider,et al.  Fixation of Transforaminal Sacrum Fractures: A Biomechanical Study , 1993, Journal of orthopaedic trauma.

[34]  J Windolf,et al.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits]. , 2007, Der Unfallchirurg.

[35]  H. Sagi,et al.  Inadvertent intraforaminal iliosacral screw placement despite apparent appropriate positioning on intraoperative fluoroscopy. , 2005, Journal of orthopaedic trauma.

[36]  J. Keating,et al.  Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. , 1999, Journal of orthopaedic trauma.

[37]  D. Templeman,et al.  Proximity of iliosacral screws to neurovascular structures after internal fixation. , 1996, Clinical orthopaedics and related research.

[38]  A. Peitzman,et al.  Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions. , 1995, The Journal of trauma.

[39]  J. Windolf,et al.  Perkutane, 2D-fluoroskopisch navigierte Sakrumverschraubung in Rückenlage , 2007, Der Unfallchirurg.

[40]  C. Bono,et al.  The Effect of Sacral Fracture Malreduction on the Safe Placement of Iliosacral Screws , 2003, Journal of orthopaedic trauma.

[41]  R. Rosenberger,et al.  Stabilisierung des dorsalen Beckenrings mit eingeschobener Platte , 2007, Operative Orthopädie und Traumatologie.

[42]  R. Hsu,et al.  Percutaneous placement of iliosacral screws for unstable pelvic ring injuries: comparison between one and two C-arm fluoroscopic techniques. , 2006, The Journal of trauma.

[43]  B. Füchtmeier,et al.  Die minimal-invasive Stabilisierung des dorsalen Beckenrings mit dem transiliakalen Fixateur interne (TIFI) , 2004, Der Unfallchirurg.

[44]  M. Routt,et al.  Author's Reply: Regarding Safe and Effective Placement of Ileosacral Screws , 1996 .

[45]  M. Bircher,et al.  Delays in definitive reconstruction of complex pelvic and acetabular fractures. , 2006, The Journal of bone and joint surgery. British volume.