Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging.

PURPOSE To validate the use of particle traces derived from four-dimensional (4D) flow magnetic resonance (MR) imaging to quantify in vivo the caval flow contribution to the pulmonary arteries (PAs) in patients who had been treated with the Fontan procedure. MATERIALS AND METHODS The institutional review boards approved this study, and informed consent was obtained. Twelve healthy volunteers and 10 patients with Fontan circulation were evaluated. The particle trace method consists of creating a region of interest (ROI) on a blood vessel, which is used to emit particles with a temporal resolution of approximately 40 msec. The flow distribution, as a percentage, is then estimated by counting the particles arriving to different ROIs. To validate this method, two independent observers used particle traces to calculate the flow contribution of the PA to its branches in volunteers and compared it with the contribution estimated by measuring net forward flow volume (reference method). After the method was validated, caval flow contributions were quantified in patients. Statistical analysis was performed with nonparametric tests and Bland-Altman plots. P < .05 was considered to indicate a significant difference. RESULTS Estimation of flow contributions by using particle traces was equivalent to estimation by using the reference method. Mean flow contribution of the PA to the right PA in volunteers was 54% ± 3 (standard deviation) with the reference method versus 54% ± 3 with the particle trace method for observer 1 (P = .4) and 54% ± 4 versus 54% ± 4 for observer 2 (P = .6). In patients with Fontan circulation, 87% ± 13 of the superior vena cava blood flowed to the right PA (range, 63%-100%), whereas 55% ± 19 of the inferior vena cava blood flowed to the left PA (range, 22%-82%). CONCLUSION Particle traces derived from 4D flow MR imaging enable in vivo quantification of the caval flow distribution to the PAs in patients with Fontan circulation. This method might allow the identification of patients at risk of developing complications secondary to uneven flow distribution. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120778/-/DC1.

[1]  A. Yoganathan,et al.  Pulmonary hepatic flow distribution in total cavopulmonary connections: extracardiac versus intracardiac. , 2011, Journal of Thoracic and Cardiovascular Surgery.

[2]  M. Fogel,et al.  The nature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the Fontan operation. , 1997, The Journal of thoracic and cardiovascular surgery.

[3]  Guang-Zhong Yang,et al.  Helical and Retrograde Secondary Flow Patterns in the Aortic Arch Studied by Three‐Directional Magnetic Resonance Velocity Mapping , 1993, Circulation.

[4]  Titus Kuehne,et al.  Flow‐sensitive four‐dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: A validation study , 2010, Journal of magnetic resonance imaging : JMRI.

[5]  Philipp Beerbaum,et al.  Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition , 2012, Journal of Cardiovascular Magnetic Resonance.

[6]  A. Yoganathan,et al.  Visualization of flow structures in Fontan patients using 3-dimensional phase contrast magnetic resonance imaging. , 2012, The Journal of thoracic and cardiovascular surgery.

[7]  W. Gersony Fontan operation after 3 decades: what we have learned. , 2008, Circulation.

[8]  M. Buonocore,et al.  4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects , 1999, Journal of magnetic resonance imaging : JMRI.

[9]  Charles A. Taylor,et al.  Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics. , 2009, The Journal of thoracic and cardiovascular surgery.

[10]  M. Fogel,et al.  Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse. , 1999, Circulation.

[11]  P. D. del Nido,et al.  Cavopulmonary pathway modification in patients with heterotaxy and newly diagnosed or persistent pulmonary arteriovenous malformations after a modified Fontan operation. , 2011, The Journal of thoracic and cardiovascular surgery.

[12]  M. Markl,et al.  Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[13]  Tobias Schaeffter,et al.  4D Phase-Contrast Flow Cardiovascular Magnetic Resonance: Comprehensive Quantification and Visualization of Flow Dynamics in Atrial Septal Defect and Partial Anomalous Pulmonary Venous Return , 2010, Pediatric Cardiology.

[14]  P. R. Moran A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.

[15]  Jürgen Hennig,et al.  Images in cardiovascular medicine. In vivo 3-dimensional flow connectivity mapping after extracardiac total cavopulmonary connection. , 2008, Circulation.

[16]  D N Firmin,et al.  Blood flow patterns in the thoracic aorta studied with three‐directional MR velocity mapping: The effects of age and coronary artery disease , 1997, Journal of magnetic resonance imaging : JMRI.

[17]  M. Buonocore,et al.  Helical-shaped streamlines do not represent helical flow. , 2010, Radiology.

[18]  S. Uribe,et al.  Quantification of caval flow contribution to the lungs in vivo after total cavopulmonary connection with 4-dimensional flow magnetic resonance imaging. , 2012, The Journal of thoracic and cardiovascular surgery.

[19]  T. Schaeffter,et al.  Four‐dimensional (4D) flow of the whole heart and great vessels using real‐time respiratory self‐gating , 2009, Magnetic resonance in medicine.

[20]  A. Yoganathan,et al.  Correction of pulmonary arteriovenous malformation using image-based surgical planning. , 2009, JACC. Cardiovascular imaging.

[21]  M. Yacoub,et al.  Asymmetric redirection of flow through the heart , 2000, Nature.

[22]  A. Marsden,et al.  Hepatic blood flow distribution and performance in conventional and novel Y-graft Fontan geometries: a case series computational fluid dynamics study. , 2012, The Journal of thoracic and cardiovascular surgery.

[23]  Friedhelm Beyersdorf,et al.  Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[24]  J. Deanfield,et al.  Four decades of Fontan palliation , 2010, Nature Reviews Cardiology.