Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease

Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson’s r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson’s r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.

[1]  D. King,et al.  Ultrasound beam orientation during standard two-dimensional imaging: assessment by three-dimensional echocardiography. , 1992, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  Ivan S. Salgo,et al.  FULLY AUTOMATED QUANTIFICATION OF LEFT VENTRICULAR AND LEFT ATRIAL VOLUMES FROM TRANSTHORACIC 3D ECHOCARDIOGRAPHY: A VALIDATION STUDY , 2013 .

[3]  B. Smulevitz,et al.  The validation of volumetric real-time 3-dimensional echocardiography for the determination of left ventricular function. , 2001, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  D. King,et al.  Assessment of cardiac function by three-dimensional echocardiography compared with conventional noninvasive methods. , 1995, Circulation.

[5]  Victor Mor-Avi,et al.  Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data. , 2006, European heart journal.

[6]  Bernd Hamm,et al.  Head-to-head comparison of left ventricular function assessment with 64-row computed tomography, biplane left cineventriculography, and both 2- and 3-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging as the reference standard. , 2012, Journal of the American College of Cardiology.

[7]  W. Vletter,et al.  Contributions of Simultaneous Multiplane Echocardiographic Imaging in Daily Clinical Practice , 2014, Echocardiography.

[8]  Victor Mor-Avi,et al.  Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. , 2015, European heart journal cardiovascular Imaging.

[9]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[10]  W J Manning,et al.  Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction. , 2000, American heart journal.

[11]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[12]  T. Villines,et al.  Accuracy of cardiac CT, radionucleotide and invasive ventriculography, two- and three-dimensional echocardiography, and SPECT for left and right ventricular ejection fraction compared with cardiac MRI: a meta-analysis. , 2015, European heart journal cardiovascular Imaging.

[13]  Victor Mor-Avi,et al.  Transthoracic 3D Echocardiographic Left Heart Chamber Quantification Using an Automated Adaptive Analytics Algorithm. , 2016, JACC. Cardiovascular imaging.