Low-complexity hardware design methodology for reliable and automated removal of ocular and muscular artifact from EEG

BACKGROUND AND OBJECTIVE EEG is a non-invasive tool for neuro-developmental disorder diagnosis and treatment. However, EEG signal is mixed with other biological signals including Ocular and Muscular artifacts making it difficult to extract the diagnostic features. Therefore, the contaminated EEG channels are often discarded by the medical practitioners which may result in less accurate diagnosis. Many existing methods require reference electrodes, which will create discomfort to the patient/children and cause hindrance to the diagnosis of the neuro-developmental disorder and Brain Computer Interface in the pervasive environment. Therefore, it would be ideal if these artifacts can be removed real time on the hardware platform in an automated fashion and then the denoised EEG can be used for online diagnosis in a pervasive personalized healthcare environment without the need of any reference electrode. METHODS In this paper we propose a reliable, robust and automated methodology to solve the aforementioned problem. The proposed methodology is based on the Haar function based Wavelet decompositions with simple threshold based wavelet domain denoising and artifacts removal schemes. Subsequently hardware implementation results are also presented. 100 EEG data from Physionet, Klinik für Epileptologie, Universität Bonn, Germany, Caltech EEG databases and 7 EEG data from 3 subjects from University of Southampton, UK have been studied and nine exhaustive case studies comprising of real and simulated data have been formulated and tested. The proposed methodology is prototyped and validated using FPGA platform. RESULTS Like existing literature, the performance of the proposed methodology is also measured in terms of correlation, regression and R-square statistics and the respective values lie above 80%, 79% and 65% with the gain in hardware complexity of 64.28% and improvement in hardware delay of 53.58% compared to state-of-the art approaches. Hardware design based on the proposed methodology consumes 75 micro-Watt power. CONCLUSIONS The automated methodology proposed in this paper, unlike the state of the art methods, can remove blink and muscular artifacts real time without the need of any extra electrode. Its reliability and robustness is also established after exhaustive simulation study and analysis on both simulated and real data. We believe the proposed methodology would be useful in next generation personalized pervasive healthcare for Brain Computer Interface and neuro-developmental disorder diagnosis and treatment.

[1]  Yang Jinfu,et al.  Removing ocular artifacts from mixed EEG signals with FastKICA and DWT , 2015 .

[2]  Raveendran Paramesran,et al.  Artifacts-matched blind source separation and wavelet transform for multichannel EEG denoising , 2015, Biomed. Signal Process. Control..

[3]  Chang-Hwan Im,et al.  Detection of eye blink artifacts from single prefrontal channel electroencephalogram , 2016, Comput. Methods Programs Biomed..

[4]  Mona Sethi Gupta,et al.  Neurodevelopmental Disorders in Children Autism and ADHD , 2008 .

[5]  Tobias S. Andersen,et al.  Classification of independent components of EEG into multiple artifact classes. , 2015, Psychophysiology.

[6]  Koushik Maharatna,et al.  On the existence of synchrostates in multichannel EEG signals during face-perception tasks , 2015, ArXiv.

[7]  Jean Gotman,et al.  Automatic removal of eye movement artifacts from the EEG using ICA and the dipole model , 2009 .

[8]  Manish N. Tibdewal,et al.  Detection and classification of Eye Blink Artifact in electroencephalogram through Discrete Wavelet Transform and Neural Network , 2015, 2015 International Conference on Pervasive Computing (ICPC).

[9]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[10]  Bashir M. Al-Hashimi,et al.  Algorithm and Architecture for N-D Vector Cross-Product Computation , 2011, IEEE Transactions on Signal Processing.

[11]  Gang Wang,et al.  The Removal of EOG Artifacts From EEG Signals Using Independent Component Analysis and Multivariate Empirical Mode Decomposition , 2016, IEEE Journal of Biomedical and Health Informatics.

[12]  Wim Van Paesschen,et al.  Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram , 2006, IEEE Transactions on Biomedical Engineering.

[13]  Rajesh Patel,et al.  Ocular artifact suppression from EEG using ensemble empirical mode decomposition with principal component analysis , 2016, Comput. Electr. Eng..

[14]  Jeena Joy,et al.  DENOISING USING SOFT THRESHOLDING , 2013 .

[15]  Bashir I. Morshed,et al.  Unsupervised Eye Blink Artifact Denoising of EEG Data with Modified Multiscale Sample Entropy, Kurtosis, and Wavelet-ICA , 2015, IEEE Journal of Biomedical and Health Informatics.

[16]  Sabine Van Huffel,et al.  Source Separation From Single-Channel Recordings by Combining Empirical-Mode Decomposition and Independent Component Analysis , 2010, IEEE Transactions on Biomedical Engineering.

[17]  Sidney J Segalowitz,et al.  An event-related source localization study of response monitoring and social impairments in autism spectrum disorder. , 2011, Psychophysiology.

[18]  Christiaan Burger,et al.  Removal of EOG artefacts by combining wavelet neural network and independent component analysis , 2015, Biomed. Signal Process. Control..

[19]  Ángel Navia-Vázquez,et al.  Automatic removal of ocular artefacts using adaptive filtering and independent component analysis for electroencephalogram data , 2012, IET Signal Process..

[20]  C. Joyce,et al.  Automatic removal of eye movement and blink artifacts from EEG data using blind component separation. , 2004, Psychophysiology.

[21]  Dennis J. McFarland,et al.  Design and operation of an EEG-based brain-computer interface with digital signal processing technology , 1997 .

[22]  Amit Acharyya,et al.  Coordinate Rotation Based Low Complexity N-D FastICA Algorithm and Architecture , 2011, IEEE Transactions on Signal Processing.

[23]  Stephen Faul,et al.  Automatic detection of EEG artefacts arising from head movements using EEG and gyroscope signals. , 2013, Medical engineering & physics.

[24]  Bart Vanrumste,et al.  Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP. , 2010, Psychophysiology.

[25]  Seán F. McLoone,et al.  The Use of Ensemble Empirical Mode Decomposition With Canonical Correlation Analysis as a Novel Artifact Removal Technique , 2013, IEEE Transactions on Biomedical Engineering.

[26]  O. Pascalis,et al.  Independent Component Analysis Reveals Atypical Electroencephalographic Activity During Visual Perception in Individuals with Autism , 2009, Biological Psychiatry.

[27]  Jing Hu,et al.  Removal of EOG and EMG artifacts from EEG using combination of functional link neural network and adaptive neural fuzzy inference system , 2015, Neurocomputing.

[28]  M. A. Sovierzoski,et al.  Identifying eye blinks in EEG signal analysis , 2008, 2008 International Conference on Information Technology and Applications in Biomedicine.

[29]  Lotfi Senhadji,et al.  Removal of muscle artifact from EEG data: comparison between stochastic (ICA and CCA) and deterministic (EMD and wavelet-based) approaches , 2012, EURASIP J. Adv. Signal Process..

[30]  K Lehnertz,et al.  Indications of nonlinear deterministic and finite-dimensional structures in time series of brain electrical activity: dependence on recording region and brain state. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[31]  L. Auret,et al.  Early Detection of risk of autism spectrum disorder based on recurrence quantification analysis of electroencephalographic signals , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[32]  Martin J. McKeown,et al.  Removing electroencephalographic artifacts: comparison between ICA and PCA , 1998, Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378).

[33]  D Bellinger,et al.  The long-term effects of exposure to low doses of lead in childhood. An 11-year follow-up report. , 1990, The New England journal of medicine.