Fracture of a Sivash-Range of Motion Femoral Stem at the Diaphyseal Spline
暂无分享,去创建一个
[1] H. Matar,et al. Long-Term Survivorship of Modular Cementless Femoral Stem in Complex Primary Total Hip Arthroplasty: A Concise Minimum 15-Year Follow-Up Report. , 2021, The Journal of arthroplasty.
[2] T. Wright,et al. Fracture of an S-ROM stem at the sleeve-stem junction , 2018, Arthroplasty today.
[3] R. Shah,et al. Alarmingly High Rate of Implant Fractures in One Modular Femoral Stem Design: A Comparison of Two Implants. , 2017, The Journal of arthroplasty.
[4] D. Dennis,et al. Fracture of a Spline of the Femoral Stem in an Ingrown Modular Hip Implant , 2016, Hip international : the journal of clinical and experimental research on hip pathology and therapy.
[5] J. Laffosse. Removal of well-fixed fixed femoral stems. , 2016, Orthopaedics & traumatology, surgery & research : OTSR.
[6] O. Huk,et al. Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis , 2015, HSS journal : the musculoskeletal journal of Hospital for Special Surgery.
[7] Young-Min Kwon,et al. Modular hip implant fracture at the stem-sleeve interface. , 2015, Orthopedics.
[8] W. Walter,et al. The S-ROM hydroxyapatite proximally-coated modular femoral stem in revision hip replacement: results of 397 hips at a minimum ten-year follow-up. , 2014, The bone & joint journal.
[9] W. Walter,et al. Spontaneous fracture of diaphyseal stem of S-ROM femoral prosthesis , 2014, BMJ Case Reports.
[10] N. Mehran,et al. Failure of a modular hip implant at the stem-sleeve interface. , 2013, Orthopedics.
[11] J. Currier,et al. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips. , 2012, The Journal of arthroplasty.
[12] E. Swarts,et al. Proximal Component Modularity in THA—At What Cost?: An Implant Retrieval Study , 2012, Clinical orthopaedics and related research.
[13] R. Calfee,et al. Modular femoral stem-sleeve junction failure after primary total hip arthroplasty. , 2009, The Journal of arthroplasty.
[14] Alan M Kop,et al. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. , 2009, The Journal of arthroplasty.
[15] R. Jones,et al. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results. , 1999, The Journal of bone and joint surgery. American volume.
[16] J. Lawrence,et al. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. , 1994, The Journal of arthroplasty.