Wind turbine SCADA alarm analysis for improving reliability

Previous research for detecting incipient wind turbine failures, using condition monitoring algorithms, concentrated on wind turbine Supervisory Control and Data Acquisition (SCADA) signals, such as power output, wind speed and bearing temperatures, using power-curve and temperature relationships. However, very little research effort has been made on wind turbine SCADA alarms. When wind turbines are operating in significantly sized wind farms, these alarm triggers are overwhelming for operators or maintainers alike because of large number occurring in a 10 min SCADA period. This paper considers these alarms originating in two large populations of modern onshore wind turbines over a period of 1‐2 years. First, an analysis is made on where the alarms originate. Second, a methodology for prioritizing the alarms is adopted from an oil and gas industry standard to show the seriousness of the alarm data volume. Third, two methods of alarm analysis, time-sequence and probability-based, are proposed and demonstrated on the data from one of the wind turbine populations, considering pitch and converter systems with known faults. The results of this work show that alarm data require relatively little storage yet provide rich condition monitoring information. Both the time-sequence and probability-based analysis methods have the potential to rationalize and reduce alarm data, providing valuable fault detection, diagnosis and prognosis from the conditions under which the alarms are generated. These methods should be developed and integrated into an intelligent alarm handling system for wind farms, aimed at improving wind turbine reliability to reduce downtime, increase availability and leading to a well-organized maintenance schedule. Copyright © 2011 John Wiley & Sons, Ltd.

[1]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[2]  Peter Tavner,et al.  Condition monitoring and fault diagnosis of a wind turbine synchronous generator drive train , 2009 .

[3]  Yanhui Feng,et al.  Methodology and results of the reliawind reliability field study , 2010 .

[4]  Martin Achmus,et al.  Copenhagen Offshore Wind 2005 , 2005 .

[5]  Henrik Stiesdal,et al.  Design for Reliability , 2005 .

[6]  Peter Tavner,et al.  Reliability of wind turbine subassemblies , 2009 .

[7]  Simon J. Watson,et al.  Physics of Failure approach to wind turbine condition based maintenance , 2009 .

[8]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[9]  Peter Tavner,et al.  Failure Modes and Effects Analysis (FMEA) for wind turbines. , 2010 .

[10]  Yingning Qiu,et al.  Use of SCADA and CMS signals for failure detection and diagnosis of a wind turbine gearbox , 2011 .

[11]  David Infield,et al.  Online wind turbine fault detection through automated SCADA data analysis , 2009 .

[12]  Yanhui Feng,et al.  Early experiences with UK round 1 offshore wind farms , 2010 .

[13]  Peter Tavner,et al.  Reliability analysis for wind turbines , 2007 .

[14]  Theodore Wildi,et al.  Electrical Machines, Drives, and Power Systems , 1990 .

[15]  Peter Tavner,et al.  Wind turbine downtime and its importance for offshore deployment. , 2011 .