Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.

The transient elastohydrodynamic lubrication (EHL) analysis was performed in this study for a typical metal-on-metal bearing employing a polyethylene backing underneath a metallic cup inlay under dynamic operating conditions of load and speed representative of normal walking. A ball-in-socket configuration was adopted to represent the articulation between the femoral head and the acetabular cup. The governing Reynolds and elasticity equations were solved simultaneously by using both finite difference and finite element methods. The predicted transient film thickness from the present study was compared with the estimation based on the quasi-static analysis. It was found that the polyethylene backing employed in the typical metal-on-metal hip bearing, combined with dynamic squeeze-film action, significantly improved the transient lubricant film thickness under cyclic walking and consequently a fluid film lubrication regime was possible for smooth bearing surfaces with an average roughness less than 0.005 microm.

[1]  D. Dowson,et al.  Prediction of lubricating film thickness in UHMWPE hip joint replacements. , 2001, Journal of biomechanics.

[2]  L. Dorr,et al.  Total Hip Arthroplasty with Use of the Metasul Metal-on-Metal Articulation: Four to Seven-Year Results* , 2000, The Journal of bone and joint surgery. American volume.

[3]  J. Fisher,et al.  Biological reactions to wear debris in total joint replacement , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  J. F. Booker,et al.  Spherical Bearings: Static and Dynamic Analysis Via the Finite Element Method , 1980 .

[5]  D. Dowson,et al.  Direct experimental evidence of lubrication in a metal-on-metal total hip replacement tested in a joint simulator , 2000 .

[6]  Z. Jin,et al.  Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[7]  D Dowson,et al.  A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials , 1999 .

[8]  C. Rieker,et al.  Analysis of 118 second-generation metal-on-metal retrieved hip implants , 1999 .

[9]  D. Dowson,et al.  Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  Roy D. Crowninshield,et al.  The influences of lubricant and material on polymer/CoCr sliding friction , 2003 .

[11]  F. C. Wang,et al.  Prediction of elastic deformation of acetabular cups and femoral heads for lubrication analysis of artificial hip joints , 2004 .

[12]  C. J. Hooke,et al.  The Minimum Film Thickness in Line Contacts During Reversal of Entrainment , 1993 .

[13]  Z. Jin,et al.  Elastohydrodynamic lubrication analysis of metal-on-metal hip prostheses under steady state entraining motion , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[14]  3-D model of a total hip replacement in vivo providing hydrodynamic pressure and film thickness for walking and bicycling. , 2003, Journal of biomechanical engineering.

[15]  J. Medley,et al.  Numerical Analysis of Time-Varying Fluid Film Thickness in Metal-Metal Hip Implants in Simulator Tests , 1998 .