Modal S-Parameter Estimation of EUT Connection of Conducted Disturbance Measurement System

A method to determine the modal S-parameters of the input / output ports of the equipment under test (EUT) connection of the conducted disturbance measurement system is investigated. Since the structure of the input terminal of the EUT connection is AC power plug itself, the modal S-parameter at the input port of the EUT connection cannot be measured directly with a vector network analyzer (VNA). To measure the modal S-parameter, the EUT connection needs to be measured through the AC-SMA adapter. In order to remove the effect of the AC-SMA adapter and estimate the unknown modal S-parameter of the EUT connection, the EUT connection with AC-SMA adapter is terminated with open, short and $50 \Omega$ matching. From these measurement results, the modal S-parameters of input / output ports of the EUT connection are estimated. As a result, the modal S-parameters of the input / output ports are quite different. Therefore, the influence of the modal S-parameter due to the difference in the structure of the input / output ports of the EUT connection cannot be ignored.

[1]  Osami Wada,et al.  Influence of an AC-coaxial adapter on measurements of the AMN impedance , 2015 .

[2]  Hiroki Ohta,et al.  Characteristics of Radiation Noise from an LED Lamp and Its Effect on the BER Performance of an OFDM System for DTTB , 2014, IEEE Transactions on Electromagnetic Compatibility.

[3]  K. Gotoh,et al.  Measurement and modeling of electromagnetic noise from LED light bulbs , 2013, IEEE Electromagnetic Compatibility Magazine.

[4]  Ifong Wu,et al.  Impedance characterastic of new type measurement system for measuring conducted disturbance , 2017, 2017 International Symposium on Electromagnetic Compatibility - EMC EUROPE.

[5]  Osami Wada,et al.  Calibration Methods for AC-Coaxial Adapter Used in AMN Impedance Measurements , 2016, IEEE Transactions on Electromagnetic Compatibility.

[6]  Y. Akiyama,et al.  Issues on the method of conducted disturbances measurement by using coupling and decoupling networks for emission , 2012, International Symposium on Electromagnetic Compatibility - EMC EUROPE.

[7]  Inoue Hiroshi,et al.  Measurement of electromagnetic noise radiated from various LED lamps , 2011 .

[8]  Uwe Karsten,et al.  VNA Measurement of Common-Mode Impedance of Coupling/Decoupling Networks in Conductive Immunity Testing , 2018, IEEE Transactions on Electromagnetic Compatibility.

[9]  Ifong Wu,et al.  Evaluation of electromagnetic radiation from the DC side of a photovoltaic power generation system , 2015, IEEE Electromagnetic Compatibility Magazine.