Effect of Instrument Orientation on the Accuracy of Intraocular Pressure Measurements in Human Cadaveric Eyes: Manometric Evaluation of the Model 30 Classic Pneumatonometer and Tono-Pen XL

PurposeTo determine the effects of probe orientation on the accuracy of intraocular pressure (IOP) measurements obtained with pneumatonometry (Model 30 Classic Pneumatonometer, Reichert Ophthalmic Instruments, Depew, NY) and with a handheld electronic tonometer (Tono-Pen XL, Reichert Ophthalmic Instruments, Depew, NY). Materials and MethodsSix enucleated human eyes were obtained fewer than 24 hours postmortem. IOP was maintained at 10, 20, and 30 mm Hg, sequentially, via liquid column manometry. At each IOP setpoint, the eyes were positioned to mimic a sitting, supine, and prone patient. Pneumatonometry was performed in the sitting and supine orientations. Tono-Pen measurements were performed in the sitting, supine, and prone orientations. Accuracy was analyzed using multifactor repeated measures analysis of variance, and one-sample t tests. ResultsAt all IOP setpoints, for both instruments, probe orientation had no significant effect on the IOP measurement (pneumatonometer P=0.58; Tono-Pen P=0.85). At all 3 setpoints (10, 20, and 30 mm Hg) the pneumatonometer overestimated IOP (P<0.0001; P<0.0001; P=0.005, respectively). The Tono-Pen overestimated IOP at the 10 mm Hg setpoint (P<0.0001), but underestimated IOP at the 20 and 30 mm Hg setpoints (P=0.03; P<0.0001, respectively). ConclusionsUnder experimental conditions, probe orientation had no significant effect on IOP measurements for either instrument, suggesting that both can be used without correction in the tested orientations. In enucleated human cadaveric eyes, the pneumatonometer overestimated IOP at all setpoints. The handheld electronic tonometer overestimated IOP at 10 mm Hg, but underestimated IOP at the higher setpoints. It is unknown if these findings are generalizable to human eyes in vivo.

[1]  R. Weinreb,et al.  Intraocular pressure measurements throughout the 24 h , 2009, Current opinion in ophthalmology.

[2]  C. Bunce,et al.  A comparison of four methods of tonometry: method agreement and interobserver variability , 2005, British Journal of Ophthalmology.

[3]  D. Kripke,et al.  Twenty-four-hour intraocular pressure pattern associated with early glaucomatous changes. , 2003, Investigative ophthalmology & visual science.

[4]  G. Johnson,et al.  Comparison of Goldmann applanation tonometry with the Tonopen for measuring intraocular pressure in a population-based glaucoma survey in rural West Bengal , 2002, Ophthalmic epidemiology.

[5]  M. Bafa,et al.  Clinical comparison of the measurement of the IOP with the ocular blood flow tonometer, the Tonopen XL and the Goldmann applanation tonometer. , 2001, Acta ophthalmologica Scandinavica.

[6]  A. Mermoud,et al.  New TonoPen XL: Comparison with the Goldmann tonometer , 2001, Eye.

[7]  D. Machin,et al.  Accuracy of clinical estimates of intraocular pressure in Chinese eyes. , 2000, Ophthalmology.

[8]  K. Damji,et al.  Positive correlation between Tono-Pen intraocular pressure and central corneal thickness. , 1998, Ophthalmology.

[9]  J. Schuman,et al.  Tonometry in adults and children. A manometric evaluation of pneumatonometry, applanation, and TonoPen in vitro and in vivo. , 1998, Ophthalmology.

[10]  P. Foster,et al.  Central corneal thickness and intraocular pressure in a Mongolian population. , 1998, Ophthalmology.

[11]  A. Wigers,et al.  Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer. , 1994, The British journal of ophthalmology.

[12]  R. Stein,et al.  The effect of corneal thickness on applanation tonometry. , 1993, American journal of ophthalmology.

[13]  M. Neudorfer,et al.  Tono-Pen tonometry in normal and in post-keratoplasty eyes. , 1992, The British journal of ophthalmology.

[14]  W. A. Boothe,et al.  The Tono-Pen. A manometric and clinical study. , 1988, Archives of ophthalmology.

[15]  R. Rössler,et al.  Comparison of intraocular pressure measurements with the Oculab Tono-Pen vs manometry in humans shortly after death. , 1988, American journal of ophthalmology.

[16]  D. Shin,et al.  Comparison of the Tono-Pen to the Goldmann applanation tonometer. , 1988, Archives of ophthalmology.

[17]  P. Lichter,et al.  Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. , 1987, Ophthalmology.

[18]  D. Minckler,et al.  Clinical evaluation of the Oculab Tono-Pen. , 1987, American journal of ophthalmology.

[19]  G. Sanborn,et al.  Intraocular and episcleral venous pressure increase during inverted posture. , 1987, American journal of ophthalmology.

[20]  R. Moses,et al.  The pneumatonograph. A laboratory study. , 1979, Archives of ophthalmology.

[21]  H. Quigley,et al.  Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer. , 1975, American journal of ophthalmology.

[22]  N. Ehlers,et al.  APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS , 1975, Acta ophthalmologica.

[23]  M. Langham,et al.  A rapid pneumatic applanation tonometer. Comparative findings and evaluation. , 1968, Archives of ophthalmology.