Some simple rules for contrast, signal-to-noise and resolution in in-line x-ray phase-contrast imaging.

Simple analytical expressions are derived for the spatial resolution, contrast and signal-to-noise in X-ray projection images of a generic phase edge. The obtained expressions take into account the maximum phase shift generated by the sample and the sharpness of the edge, as well as such parameters of the imaging set-up as the wavelength spectrum and the size of the incoherent source, the source-to-object and object-to-detector distances and the detector resolution. Different asymptotic behavior of the expressions in the cases of large and small Fresnel numbers is demonstrated. The analytical expressions are compared with the results of numerical simulations using Kirchhoff diffraction theory, as well as with experimental X-ray measurements.

[1]  C J Kotre,et al.  Short communication: anomalous image quality phantom scores in magnification mammography: evidence of phase contrast enhancement. , 2002, The British journal of radiology.

[2]  Sean Brennan,et al.  A suite of programs for calculating x‐ray absorption, reflection, and diffraction performance for a variety of materials at arbitrary wavelengths , 1992 .

[3]  P. Cloetens,et al.  Phase objects in synchrotron radiation hard x-ray imaging , 1996 .

[4]  A. Snigirev,et al.  On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation , 1995 .

[5]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[6]  S. Geller Parameter interaction in least squares structure refinement , 1961 .

[7]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[8]  G. Tromba,et al.  COHERENCE-BASED EDGE DIFFRACTION SHARPENING OF X-RAY IMAGES : A SIMPLE MODEL , 1999 .

[9]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[10]  M. Teague Deterministic phase retrieval: a Green’s function solution , 1983 .

[11]  S. Wilkins,et al.  Contrast and resolution in imaging with a microfocus x-ray source , 1997 .

[12]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[13]  P Cloetens,et al.  Fractional Talbot imaging of phase gratings with hard x rays. , 1997, Optics letters.

[14]  Y. Amemiya Imaging plates for use with synchrotron radiation. , 1995, Journal of synchrotron radiation.

[15]  David A. Hammer,et al.  Point-projection x-ray radiography using an X pinch as the radiation source , 2001 .

[16]  S. Wilkins,et al.  Linear algorithms for phase retrieval in the Fresnel region , 2004 .

[17]  S. Wilkins,et al.  Generalized eikonal of partially coherent beams and its use in quantitative imaging. , 2004, Physical review letters.

[18]  S. Wilkins,et al.  On the optimization of experimental parameters for x-ray in-line phase-contrast imaging , 2005 .

[19]  V. E. Cosslett,et al.  The X‐Ray Shadow Microscope , 1953 .

[20]  G. Kyrala,et al.  Applications of X rays generated from lasers and other bright sources II : 30-31 July 2001, San Diego, USA , 1997 .

[21]  W. C. Hamilton Significance tests on the crystallographic R factor , 1965 .

[22]  Y Ueno,et al.  Laser-stimulated luminescence used to measure x-ray diffraction of a contracting striated muscle. , 1987, Science.

[23]  Andrzej Krol,et al.  Laser-driven x-ray source for diagnostic radiology , 1997, Optics & Photonics.

[24]  Timur E. Gureyev,et al.  On x-ray phase imaging with a point source , 1998 .

[25]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.