Computer-assisted periacetabular screw placement: Comparison of different fluoroscopy-based navigation procedures with conventional technique.

The current gold standard for operatively treated acetabular fractures is open reduction and internal fixation. Fractures with minimal displacement may be stabilised by minimally invasive methods such as percutaneous periacetabular screws. However, their placement is a demanding procedure due to the complex pelvic anatomy. The aim of this study was to evaluate the accuracy of periacetabular screw placement assessing pre-defined placement corridors and comparing different fluoroscopy-based navigation procedures and the conventional technique. For each screw an individual periacetabular placement corridor was preoperatively planned using the planning software iPlan CMF(©) 3.0 (BrainLAB). 210 screws (retrograde anterior column screws, retrograde posterior column screws, supraacetabular ilium screws) were placed in an artificial Synbone pelvis model (30 hemipelves) and in human cadaver specimen (30 hemipelves). 2D- and 3D-fluoroscopy-based navigation procedures were compared to the conventional technique. Insertion time and radiation exposure to specimen were also recorded. The achieved screw position was postoperatively assessed by an Iso-C(3D) scan. Perforations of bony cortices or articular surfaces were analysed and the screw deviation severity (difference of the operatively achieved screw position and the preoperatively planned screw position in reference to the pre-defined corridors) was determined using image fusion. Using 3D-fluoroscopy-based navigation, the screw perforation rate (7%) was significantly lower compared to 2D-fluoroscopy-based navigation (20%). For all screws, the deviation severity was significantly lower using a 3D- compared to a 2D-fluoroscopy-based navigation and the conventional technique. Analysing the posterior column screws, the screw deviation severity was significantly lower using 3D- compared to 2D-fluoroscopy-based navigation. However, for the anterior column screw, the screw deviation severity was similar regardless of the imaging method. Despite the advantages of the 3D-fluoroscopy-based navigation, this method led to significantly longer total procedure and fluoroscopic times, and the applied radiation dose was significantly higher. Percutaneous periacetabular screw placement is demanding. Especially for posterior column screws, due to a lower perforation rate and a higher accuracy in periacetabular screw placement, 3D-fluoroscopy-based navigation procedure appears to be the method of choice for image guidance in acetabular surgery.

[1]  Chung-Hwan Chen,et al.  Percutaneous antegrade screwing for anterior column fracture of acetabulum with fluoroscopic-based computerized navigation , 2008, Archives of Orthopaedic and Trauma Surgery.

[2]  J. Alonso,et al.  Extended iliofemoral versus triradiate approaches in management of associated acetabular fractures. , 1994, Clinical orthopaedics and related research.

[3]  J. Matta,et al.  Displaced Acetabular Fractures , 1988, Clinical orthopaedics and related research.

[4]  A. Peitzman,et al.  Percutaneous iliosacral screw fixation: early treatment for unstable posterior pelvic ring disruptions. , 1993, The Journal of trauma.

[5]  Ulrich Stöckle,et al.  Image guidance in pelvic and acetabular surgery--expectations, success and limitations. , 2007, Injury.

[6]  S R Garfin,et al.  Placement of pedicle screws in the thoracic spine. Part II: An anatomical and radiographic assessment. , 1995, The Journal of bone and joint surgery. American volume.

[7]  M. F. Parry,et al.  A Retrospective Analysis , 1990 .

[8]  J. Windolf,et al.  Perkutane, 2D-fluoroskopisch navigierte Sakrumverschraubung in Rückenlage , 2007, Der Unfallchirurg.

[9]  A. Jones,et al.  Percutaneous fixation of the columns of the acetabulum: a new technique. , 1998, Journal of orthopaedic trauma.

[10]  J. Matta,et al.  Heterotopic ossification following operative treatment of acetabular fracture. An analysis of risk factors. , 1994, Clinical orthopaedics and related research.

[11]  L Kinzl,et al.  [Radiation dosage in orthopedics -- a comparison of computer-assisted procedures]. , 2003, Der Unfallchirurg.

[12]  G. Fenzl,et al.  Azetabulumfrakturen-operative versus konservative Behandlung , 1990, Unfallchirurgie.

[13]  J Windolf,et al.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial]. , 2006, Der Unfallchirurg.

[14]  U. Stöckle,et al.  Navigationsverfahren in der Becken- und Azetabulumchirurgie , 2002, Der Unfallchirurg.

[15]  J. Matta,et al.  Fractures of the acetabulum. Early results of a prospective study. , 1986, Clinical orthopaedics and related research.

[16]  Dongsheng Zhou,et al.  Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum , 2009, Archives of Orthopaedic and Trauma Surgery.

[17]  C. Roberts,et al.  Percutaneous fixation of the pelvic ring: an update. , 2007, The Journal of bone and joint surgery. British volume.

[18]  J. Windolf,et al.  Computerassistierte Verschraubung des hinteren Beckenrings , 2006, Der Unfallchirurg.

[19]  P. Giannoudis,et al.  Mapping the columns of the acetabulum--implications for percutaneous fixation. , 2010, Injury.

[20]  E. Reichle,et al.  Einbringung von Pedikelschrauben unter Einsatz unterschiedlicher Unterstützungsverfahren , 2001, Der Orthopäde.

[21]  J. Mast,et al.  The extended ilioinguinal approach for specific both column fractures. , 1994, Clinical orthopaedics and related research.

[22]  Gang Wang,et al.  Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: a study of 164 virtual three-dimensional models. , 2009, Injury.

[23]  R. Hoffmann,et al.  Treatment of Complex Acetabular Fractures Through a Modified Extended Iliofemoral Approach , 2002, Journal of orthopaedic trauma.

[24]  Emile Letournel,et al.  Fractures of the Acetabulum , 1981, Springer Berlin Heidelberg.

[25]  Ulrich Stöckle,et al.  Genauigkeit der CT-basierten Navigation von Pedikelschrauben an der Brustwirbelsäule im Vergleich zur konventionellen Technik , 2004, Der Unfallchirurg.

[26]  P. Simonian,et al.  Closed reduction and percutaneous skeletal fixation of sacral fractures. , 1996, Clinical orthopaedics and related research.

[27]  L. P. Nolte,et al.  Bildwandler-gestützte Navigation Eine experimentelle Studie zu Beckenverschraubungen , 2001, Der Unfallchirurg.

[28]  M. Arand,et al.  Klinische Präzision der C-Arm-Navigation an der Brust- und Lendenwirbelsäule , 2008, Zentralblatt fur Chirurgie.

[29]  P. Simonian,et al.  Preliminary Report: The Retrograde Medullary Superior Pubic Ramus Screw for the Treatment of Anterior Pelvic Ring Disruptions: A New Technique , 1995, Journal of orthopaedic trauma.

[30]  J. Matta Fractures of the Acetabulum: Accuracy of Reduction and Clinical Results in Patients Managed Operatively within Three Weeks after the Injury* , 1996, The Journal of bone and joint surgery. American volume.

[31]  Goris Rj,et al.  Conservative treatment of fractures of the acetabulum. Results after longtime follow-up. , 1988 .

[32]  [Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study]. , 2001, Der Unfallchirurg.

[33]  F. Baumgaertel [Diagnosis, classification and surgical indications in acetabulum fractures]. , 1992, Der Orthopade.

[34]  R. Brumback,et al.  A modified extensile exposure for the treatment of complex or malunited acetabular fractures. , 1988, The Journal of bone and joint surgery. American volume.

[35]  J Windolf,et al.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits]. , 2007, Der Unfallchirurg.

[36]  M. Vrahas,et al.  Surgical approaches to the acetabulum. , 1997, The Orthopedic clinics of North America.

[37]  R. Kay,et al.  Heterotopic ossification prophylaxis following operative treatment of acetabular fracture. , 1994, Clinical orthopaedics and related research.

[38]  A J Starr,et al.  Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. , 2001, Injury.

[39]  K. Weise,et al.  [Conservative therapy of acetabular fractures--indications and results]. , 1987, Aktuelle Traumatologie.

[40]  E. Letournel The treatment of acetabular fractures through the ilioinguinal approach. , 1993, Clinical orthopaedics and related research.

[41]  D. Kahler,et al.  Closed reduction and percutaneous fixation of anterior column acetabular fractures. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[42]  N P Haas,et al.  [Navigation assisted by image conversion. An experimental study on pelvic screw fixation]. , 2001, Der Unfallchirurg.

[43]  J. Matta,et al.  Fractures of the Acetabulum: A Retrospective Analysis , 1986 .

[44]  H. Tscherne,et al.  [Results of follow-up of surgical treatment of complicated acetabulum fractures with extended approaches]. , 1995, Der Unfallchirurg.

[45]  P M Rommens,et al.  Is there a role for percutaneous pelvic and acetabular reconstruction? , 2007, Injury.

[46]  Robert W. Harris,et al.  Percutaneous Screw Fixation of Fractures of the Iliac Wing and Fracture-dislocations of the Sacro-iliac Joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess “Lateral Compression Type II” Pelvic Fractures) , 2002, Journal of orthopaedic trauma.

[47]  T. Laine,et al.  Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients , 2000, European Spine Journal.

[48]  J. M. Matta,et al.  Fracture of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury , 2011 .

[49]  Tim Pohlemann,et al.  Changes in the treatment of acetabular fractures over 15 years: Analysis of 1266 cases treated by the German Pelvic Multicentre Study Group (DAO/DGU). , 2010, Injury.

[50]  D. Mears,et al.  Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone. , 1999, The Journal of the American Academy of Orthopaedic Surgeons.

[51]  R W Lindsey,et al.  The use of a virtual three-dimensional model to evaluate the intraosseous space available for percutaneous screw fixation of acetabular fractures. , 2005, The Journal of bone and joint surgery. British volume.

[52]  Philip J. Kregor,et al.  Early Results of Percutaneous Iliosacral Screws Placed with the Patient in the Supine Position , 1995, Journal of orthopaedic trauma.

[53]  N. Ebraheim,et al.  Anatomic Basis of Lag Screw Placement in the Anterior Column of the Acetabulum , 1997, Clinical orthopaedics and related research.

[54]  Amal Khoury,et al.  First Generation Computerized Fluoroscopic Navigation in Percutaneous Pelvic Surgery , 2004, Journal of orthopaedic trauma.

[55]  C Krettek,et al.  [Computer-assisted surgery for pelvic injuries]. , 2004, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen.

[56]  V. D. de Ridder,et al.  Results of 75 consecutive patients with an acetabular fracture. , 1994, Clinical orthopaedics and related research.

[57]  M Wettstein,et al.  Percutaneous retrograde screwing for stabilisation of acetabular fractures. , 2005, Injury.

[58]  E. Kotter,et al.  Computer-navigated Iliosacral Screw Insertion Reduces Malposition Rate and Radiation Exposure , 2009, Clinical orthopaedics and related research.

[59]  E. Mayr,et al.  [Approach-related results following acetabular fractures]. , 1997, Der Orthopade.

[60]  S. Gertzbein,et al.  Accuracy of Pedicular Screw Placement In Vivo , 1990, Spine.

[61]  Christian Krettek,et al.  Clinical applications--pelvis. , 2004, Injury.

[62]  F. Gebhard,et al.  Präzisionsanalyse navigationsgestützt implantierter thorakaler und lumbaler Pedikelschrauben Eine prospektive klinische Studie , 2001, Der Unfallchirurg.

[63]  B. Vock,et al.  [Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system]. , 2002, Der Unfallchirurg.

[64]  C Eggers,et al.  [Placement of pedicle screws using different navigation systems. A laboratory trial with 12 spinal preparations]. , 2002, Der Orthopade.

[65]  P. Parker,et al.  Percutaneous fluoroscopic screw fixation of acetabular fractures. , 1997, Injury.

[66]  R. Hoffmann,et al.  Operative Behandlung komplexer Azetabulumfrakturen durch den modifizierten erweiterten iliofemoralen Zugang (-Maryland-) , 2000, Der Unfallchirurg.