Safety of Silastic Sheet for Orbital Wall Reconstruction

Background Many implants are being used for the reconstruction of orbital wall fractures. The effect of the choice of implant for the reconstruction of an orbital wall fracture on the surgical outcome is under debate. The purpose of this article is to compare the outcomes of orbital wall reconstruction of small orbital wall fractures on the basis of the implants used. Methods The authors conducted a retrospective study using electronic databases. Between March 2001 and December 2012, 461 patients with orbital wall fractures were included in this study. Among them, 431 patients in whom the fracture size was less than 300 mm2 were analyzed. The fracture size was calculated using computed tomography scans of the orbit in the sagittal and coronal images. Cases in which the fracture size was less than 300 mm2 were included in this study. Results One hundred and twenty-nine patients were treated with silastic sheets; 238 patients were treated with titanium meshes; and absorbable meshes were used in the case of 64 patients. Overall, 13 patients required revision, and the revision rate was 3.0%. The revision rate of the silastic sheet group was 5.4%. In the multivariable analysis, the revision rate of the group reconstructed with silastic sheets was highly statistically significant (P=0.043, odds ratio=3.65). However, other factors such as age, sex, fracture type, and fracture size were not significant. Conclusions Reconstruction of orbital wall fractures with silastic sheets may cause more complications than that with other materials such as titanium meshes and absorbable meshes.

[1]  Young Joon Kim,et al.  Prevalence of Diplopia and Extraocular Movement Limitation according to the Location of Isolated Pure Blowout Fractures , 2012, Archives of plastic surgery.

[2]  V. Durairaj,et al.  Orbital implants for fracture repair , 2011, Current opinion in ophthalmology.

[3]  M. Brucoli,et al.  Analysis of Complications After Surgical Repair of Orbital Fractures , 2011, The Journal of craniofacial surgery.

[4]  Robert F Gilmour,et al.  Orbital floor reconstruction: a case for silicone. A 12 year experience. , 2010, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[5]  W. Nunery,et al.  Orbital Adherence Syndrome Secondary to Titanium Implant Material , 2009, Ophthalmic plastic and reconstructive surgery.

[6]  Patrick Cole,et al.  Comprehensive Management of Orbital Fractures , 2007, Plastic and reconstructive surgery.

[7]  C. Kunz,et al.  Reconstruction of orbital wall defects: critical review of 72 patients. , 2007, International journal of oral and maxillofacial surgery.

[8]  C. Czerny,et al.  A computer-based method for calculation of orbital floor fractures from coronal computed tomography scans. , 2001, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[9]  S. Ahn,et al.  Complications after Open Reduction of Blow-out Fracture using Silicone Sheet , 2001 .

[10]  B. Schmidt,et al.  Intraorbital squamous epithelial cyst: an unusual complication of Silastic implantation. , 1998, The Journal of craniofacial surgery.

[11]  K F Moos,et al.  The use of silastic as an orbital implant for reconstruction of orbital wall defects: review of 311 cases treated over 20 years. , 1995, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.