Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

We report on the design and performance of the Bicep3 instrument and its first three-year data set collected from 2016 to 2018. Bicep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. Bicep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μKCMBs and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μK arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μK arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

Caltech | Brookhaven National Laboratory | T. U. O. Tokyo | B. N. Laboratory | U. Chicago | M. Halpern | J. Bock | Z. Ahmed | R. Thakur | E. Denison | G. Hilton | K. Irwin | C. Kuo | H. Nguyen | K. Thompson | C. Tucker | K. Yoon | E. Hand | Nasa Jpl | U. Minnesota | P. Ade | S. Hildebrandt | R. Sudiwala | A. Weber | A. Schillaci | L. Zeng | P. Grimes | C. Reintsema | R. Schwarz | U. Cincinnati | S. Richter | E. Leitch | C. Pryke | L. Duband | A. Turner | J. Hubmayr | W. L. K. Wu | L. Moncelsi | D. Wiebe | HarvardCfA | S. Henderson | A. Vieregg | D. Barkats | C. Bischoff | E. Bullock | J. Filippini | S. Fliescher | K. Karkare | S. Kernasovskiy | J. Kovac | R. O’Brient | C. Sheehy | G. Teply | J. Tolan | C. L. Wong | V. Buza | M. Amiri | B. Racine | B. Schmitt | D. Beck | N. Goeckner-wald | E. Karpel | C. Vergés | Nist | E. Young | T. Namikawa | D. Goldfinger | M. I. O. Astrophysics | J. Connors | J. Grayson | S. Harrison | H. Hui | S. Kefeli | K. Megerian | B. Steinbach | J. Willmert | J. Kang | C. Umiltà | A. Soliman | H. University | S. Fatigoni | G. Hall | L. Minutolo | A. Wandui | Aix-Marseille Universite | W.L.K. Wu | S. Palladino | C. Yu | M. Dierickx | M. Eiben | H. Boenish | J. R. Cheshire IV | J. Cornelison | M. Crumrine | A. Cukierman | G. Halal | K. Lau | A. Lennox | Y. Nakato | R. W. Ogburn IV | T. Prouve | T. S. Germaine | H. Yang | C. Zhang | S. Zhang | IV R.W.Ogburn | U. Columbia | S. Grenoble | Kipacslac | J. Bock | C. Vergès | T. Prouvé | B. C. P. Ade | IV J.R.Cheshire | S. University | S. University | Harvard University | C. Yu | U. I. Urbana-Champaign | K. Thompson | T. Germaine | C. Umilta | C. Kuo | K. Thompson | Sbt Grenoble | Aix-Marseille Université | A. Vieregg | H. Nguyen

[1]  F. Englert,et al.  The Creation of the Universe as a Quantum Phenomenon , 1978 .

[2]  C. L. Kuo,et al.  Large-Area Reflective Infrared Filters for Millimeter/Sub-mm Telescopes , 2014 .

[3]  J. J. Bock,et al.  Keck array and BICEP3: spectral characterization of 5000+ detectors , 2014, Astronomical Telescopes and Instrumentation.

[4]  T. Button,et al.  High Q dielectric resonators using YBa/sub 2/Cu/sub 3/O/sub x/ thick films and polycrystalline dielectrics , 1997, IEEE transactions on applied superconductivity.

[5]  R. W. Ogburn,et al.  Observing low elevation sky and the CMB Cold Spot with BICEP3 at the South Pole , 2020, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X.

[6]  A. G. Vieregg,et al.  BICEP Array: a multi-frequency degree-scale CMB polarimeter , 2018, Astronomical Telescopes + Instrumentation.

[7]  J. J. Bock,et al.  BICEP2 and Keck array: upgrades and improved beam characterization , 2014, Astronomical Telescopes and Instrumentation.

[8]  R. B. Barreiro,et al.  Planck2018 results , 2020, Astronomy & Astrophysics.

[9]  E. Leitch,et al.  FIRST SEASON QUaD CMB TEMPERATURE AND POLARIZATION POWER SPECTRA , 2008 .

[10]  P. A. R. Ade,et al.  Optimization and sensitivity of the Keck array , 2012, Other Conferences.

[11]  The University of Tokyo,et al.  An updated analytic model for attenuation by the intergalactic medium , 2014 .

[12]  A. G. Vieregg,et al.  BICEP3 focal plane design and detector performance , 2016, Astronomical Telescopes + Instrumentation.

[13]  M. Halpern,et al.  Microwave Multiplexing on the Keck Array , 2019, Journal of Low Temperature Physics.

[14]  B. Hensley,et al.  Mapping the Magnetic Interstellar Medium in Three Dimensions over the Full Sky with Neutral Hydrogen , 2019, The Astrophysical Journal.

[15]  A. G. Vieregg,et al.  BICEP3 performance overview and planned Keck Array upgrade , 2016, Astronomical Telescopes + Instrumentation.

[16]  Johannes Hubmayr,et al.  The CLASS 150/220 GHz Polarimeter Array: Design, Assembly, and Characterization , 2019, Journal of Low Temperature Physics.

[17]  D. Kazanas Dynamics of the universe and spontaneous symmetry breaking , 1980 .

[18]  Edward J. Wollack,et al.  Advanced ACTPol Cryogenic Detector Arrays and Readout , 2015, 1510.02809.

[19]  E. Leitch,et al.  South Pole Telescope software systems: control, monitoring, and data acquisition , 2012, Other Conferences.

[20]  Giampaolo Pisano,et al.  A review of metal mesh filters , 2006, SPIE Astronomical Telescopes + Instrumentation.

[21]  Andrei Linde,et al.  A new inflationary universe scenario: A possible solution of the horizon , 1982 .

[22]  P. A. R. Ade,et al.  Design and performance of wide-band corrugated walls for the BICEP Array detector modules at 30/40 GHz , 2018, Astronomical Telescopes + Instrumentation.

[23]  M. Halpern,et al.  Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole , 2020, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X.

[24]  Chao-Lin Kuo,et al.  Assessments of Ali, Dome A, and Summit Camp for mm-wave Observations Using MERRA-2 Reanalysis , 2017, 1707.08400.

[25]  A. G. Vieregg,et al.  2017 upgrade and performance of BICEP3: a 95GHz refracting telescope for degree-scale CMB polarization , 2018, Astronomical Telescopes + Instrumentation.

[26]  A. G. Vieregg,et al.  BICEP Array cryostat and mount design , 2018, Astronomical Telescopes + Instrumentation.

[27]  A. G. Vieregg,et al.  The Keck Array: A Multi Camera CMB Polarimeter at the South Pole , 2012 .

[28]  M. Halpern,et al.  Functional Description of Read-out Electronics for Time-Domain Multiplexed Bolometers for Millimeter and Sub-millimeter Astronomy , 2008 .

[29]  G. C. Hilton,et al.  Advanced Code-Division Multiplexers for Superconducting Detector Arrays , 2011, 1110.1608.

[30]  M. Halpern,et al.  Polarization calibration of the BICEP3 CMB polarimeter at the South Pole , 2020, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy X.

[31]  P. A. R. Ade,et al.  Ultra-thin large-aperture vacuum windows for millimeter wavelengths receivers , 2018, Astronomical Telescopes + Instrumentation.

[32]  G. Bernardi,et al.  S–PASS view of polarized Galactic synchrotron at 2.3 GHz as a contaminant to CMB observations , 2018, Astronomy & Astrophysics.

[33]  G. Hilton,et al.  Time-division superconducting quantum interference device multiplexer for transition-edge sensors , 2003 .

[34]  O. Tajima,et al.  Radio-transparent multi-layer insulation for radiowave receivers. , 2013, The Review of scientific instruments.

[35]  P. A. R. Ade,et al.  Optical characterization of the BICEP3 CMB polarimeter at the South Pole , 2016, Astronomical Telescopes + Instrumentation.

[36]  J. M. Kovac,et al.  Measuring Polarization with DASI , 2002 .