Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images.

Construction of computational blood flow models from magnetic resonance (MR) scans of real arteries is a powerful tool for studying arterial hemodynamics. In this report we experimentally determine a lower bound for errors associated with such an approach, and present techniques for minimizing such errors. A known, simple three-dimensional geometry (cylindrical tube) was imaged using a commercial MR scanner, and the resulting images were used to construct finite element flow models. Computed wall-shear stresses were compared to known values and peak errors of 40-60% were found. These errors can be attributed to limited spatial resolution, image segmentation and model construction. A simple smoothing technique markedly reduced these peak errors. We conclude that smoothing is required in the construction of arterial models from in vivo MR images. If used appropriately, such images can be used to construct acceptably accurate computational models of realistic arterial geometries.

[1]  I M Katz,et al.  A technical problem in the calculation of laminar flow near irregular surfaces described by sampled geometric data. , 1995, Journal of biomechanics.

[2]  Herman J. Woltring,et al.  A fortran package for generalized, cross-validatory spline smoothing and differentiation , 1986 .

[3]  D. Liepsch,et al.  Flow Characteristics in an Anatomically Realistic Compliant Carotid Artery Bifurcation Model. , 1999, Computer methods in biomechanics and biomedical engineering.

[4]  Thomas J. R. Hughes,et al.  Computational investigations in vascular disease , 1996 .

[5]  A. Fenster,et al.  A geometrically accurate vascular phantom for comparative studies of x-ray, ultrasound, and magnetic resonance vascular imaging: construction and geometrical verification. , 1993, Medical physics.

[6]  R Greene,et al.  Computation of vascular flow dynamics from intravascular ultrasound images. , 1996, Medical engineering & physics.

[7]  I. Vesely,et al.  Automated 3-D reconstruction of vascular structures from high definition casts , 1991, IEEE Transactions on Biomedical Engineering.

[8]  F. White Viscous Fluid Flow , 1974 .

[9]  J. W. Peifer,et al.  Visualization of the abdominal aorta using three-dimensional computer models reconstructed from MR images , 1990, [1990] Proceedings of the First Conference on Visualization in Biomedical Computing.

[10]  T Altan,et al.  Fabrication of vascular replicas from magnetic resonance images. , 1995, Journal of biomechanical engineering.