American Society of Heating, Refrigerating and Air-conditioning Engineers Guideline 12-2000: Minimizing the Risk of Legionellosis Associated with Building Water Systems

American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE's) Environmental Health Committee recognized the need for a comprehensive, nationally accepted guideline to address the public health issues surrounding Legionnaires' disease. The primary focus is on control and prevention of contaminated water sources, but it is limited to discussion of cooling towers and domestic water systems. Guideline Project Committee (GPC)-12 was composed of members with diverse backgrounds ranging from physicians to consulting engineers and microbiologists to manufacturers. Investigation of Legionnaires' disease outbreaks suggested that, in most instances, transmission to humans occurred when water containing the organism was aerosolized into droplets less than 5 μm in diameter, allowing inhalation into the lungs of a susceptible host. Conventional open cooling towers are evaporative heat-transfer devices in which atmospheric air mixes with and cools warm water by evaporating a portion of the water. Heated spas generally operate in the temperature range of 32 to 40№ C, which is in the range that favors amplification. ASHRAE Guideline 12 presents information on several budding water systems that can amplify and disseminate Legionella. This chapter thus focuses on three of these amplifiers: cooling towers, evaporative condensers, and heated spas. Specific guidance is presented to minimize the risk of legionellosis associated with these devices.

[1]  V L Yu,et al.  Potable water as a cause of sporadic cases of community-acquired legionnaires' disease. , 1992, The New England journal of medicine.

[2]  R. J. Carter,et al.  Outbreak of Legionnaires' disease among cruise ship passengers exposed to a contaminated whirlpool spa , 1996, The Lancet.

[3]  V L Yu,et al.  Eradicating Legionella from hospital water. , 1997, JAMA.

[4]  J. M. Barbaree Controlling Legionella in cooling towers , 1991 .

[5]  T G Harrison,et al.  Nosocomial Legionnaires' disease in England and Wales, 1980–92 , 1994, Epidemiology and Infection.

[6]  D L Thomas,et al.  Hot tub legionellosis. Legionnaires' disease and Pontiac fever after a point-source exposure to Legionella pneumophila. , 1993, Archives of internal medicine.

[7]  J R AMOS Division of health. , 1953, Missouri medicine.

[8]  V L Yu,et al.  Copper-silver ionization: cautious optimism for Legionella disinfection and implications for environmental culturing. , 1997, American journal of infection control.

[9]  L. Mermel,et al.  Association of Legionnaires Disease with Construction: Contamination of Potable Water? , 1995, Infection Control & Hospital Epidemiology.

[10]  E. Wald,et al.  Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals. , 1997, American journal of infection control.

[11]  Barry S. Fields,et al.  PREVENTION AND CONTROL OF LEGIONELLOSIS , 1997 .

[12]  R M Wadowsky,et al.  Susceptibility of Legionella pneumophila to chlorine in tap water , 1983, Applied and environmental microbiology.

[13]  V L Yu,et al.  Intermittent use of copper-silver ionization for Legionella control in water distribution systems: a potential option in buildings housing individuals at low risk of infection. , 1998, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.