Design of electrical capacitance tomography sensors

Electrical capacitance tomography (ECT) has been developed since the late 1980s for visualization and measurement of a permittivity distribution in a cross section using a multi-electrode capacitance sensor. While the hardware and image reconstruction algorithms for ECT have been published extensively and the topics have been reviewed, few papers have been published to discuss ECT sensors and the design issues, which are crucial for a specific application. This paper will briefly discuss the principles of ECT sensors, but mostly will address key issues for ECT sensor design, with reference to some existing ECT sensors as a good understanding of the key issues would help optimization of the design of ECT sensors. The key issues to be discussed include the number and length of electrodes, the use of external and internal electrodes, implications of wall thickness, earthed screens (including the outer screen, axial end screens and radial screens), driven guard electrodes, dealing with high temperature and high pressure, twin planes for velocity measurement by cross correlation and limitations in sensor diameter. While conventional ECT sensors are circular with the electrodes in a single plane or in twin planes, some non-conventional ECT sensors, such as square, conical and 3D sensors, will also be discussed. As a practical guidance, the procedure to fabricate an ECT sensor will be given. In the end are summary and discussion on future challenges, including re-engineering of ECT sensors.

[1]  Wuqiang Yang,et al.  An impedance-analyser-based multi-channel imaging system and its applications , 2008, 2008 IEEE International Workshop on Imaging Systems and Techniques.

[2]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[3]  Wuqiang Yang,et al.  Adaptive calibration of a capacitance tomography system for imaging water droplet distribution , 2004 .

[4]  Tomasz Dyakowski,et al.  Application of electrical capacitance tomography for measurement of gas-solids flow characteristics in a pneumatic conveying system , 2001 .

[5]  Wuqiang Yang,et al.  Hardware design of electrical capacitance tomography systems , 1996 .

[6]  Wuqiang Yang,et al.  A comparative study of 3D electrical capacitance tomography , 2007 .

[7]  Liang-Shih Fan,et al.  3D‐ECT Velocimetry for Flow Structure Quantification of Gas‐Liquid‐Solid Fluidized Beds , 2008 .

[8]  O. Isaksen,et al.  A capacitance-based tomography system for interface measurement in separation vessels , 1994 .

[9]  Wuqiang Yang,et al.  Electrical capacitance tomography sensor with internal-external electrodes , 2001, SPIE Optics East.

[10]  Wuqiang Yang,et al.  Development of capacitance tomographic imaging systems for oil pipeline measurements , 1995 .

[11]  Wuqiang Yang,et al.  Tomography for multi-phase flow measurement in the oil industry , 2005 .

[12]  F. Teixeira,et al.  Sensitivity matrix calculation for fast 3-D electrical capacitance tomography (ECT) of flow systems , 2004, IEEE Transactions on Magnetics.

[13]  Brian S. Hoyle,et al.  Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors , 1992 .

[14]  Wuqiang Yang,et al.  A new image reconstruction method for tomographic investigation of fluidized beds , 2002 .

[15]  Wuqiang Yang,et al.  Calibration of capacitance tomography systems: a new method for setting system measurement range , 1996 .

[16]  Wuqiang Yang,et al.  Modelling of batch fluidised bed drying of pharmaceutical granules , 2007 .

[17]  Maurice Beck,et al.  Design of capacitance electrodes for concentration measurement of two-phase flow , 1990 .

[18]  A. Plaskowski,et al.  Cross Correlation Flowmeters, Their Design and Application , 1987 .

[19]  Wuqiang Yang,et al.  Online measurement and control of solids moisture in fluidised bed dryers , 2009 .

[20]  Wuqiang Yang,et al.  Electrical capacitance tomography for gas–solids flow measurement for circulating fluidized beds , 2005 .

[21]  Wuqiang Yang,et al.  Role of tomography in gas/solids flow measurement , 2000 .

[22]  Maurice Beck,et al.  Design of sensor electronics for electrical capacitance tomography , 1992 .

[23]  Liang-Shih Fan,et al.  Dynamics of spiral bubble plume motion in the entrance region of bubble columns and three-phase fluidized beds using 3D ECT , 2005 .

[24]  Tom Dyakowski,et al.  Imaging nylon polymerisation processes by applying electrical tomography , 2000 .

[25]  Trevor York,et al.  A miniature electrical capacitance tomograph , 2006 .

[26]  Wuqiang Yang,et al.  Sensitivity distributions of capacitance tomography sensors with parallel field excitation , 1997 .

[27]  R G Green,et al.  The spatial filtering effect of capacitance transducer electrodes (flow measurement) , 1983 .

[28]  Todd Pugsley,et al.  The dynamic calibration of an electrical capacitance tomography sensor applied to the fluidized bed drying of pharmaceutical granule , 2005 .

[29]  Ø. Isaksen,et al.  A review of reconstruction techniques for capacitance tomography , 1996 .

[30]  Wuqiang Yang,et al.  Electrical capacitance tomography with square sensor , 1999 .

[31]  R. C. Waterfall,et al.  Combustion imaging from electrical impedance measurements , 1996 .

[32]  R B White,et al.  Internal Structures in Fluid Beds of Different Scales: An Application of Electrical Capacitance Tomography. , 1999 .

[33]  Yan Hua,et al.  Three-dimensional analysis of electrical capacitance tomography sensing fields , 1999 .

[34]  P. Senior,et al.  Investigation of batch fluidized-bed drying by mathematical modeling, CFD simulation and ECT measurement , 2008 .

[35]  Wuqiang Yang Modelling of capacitance tomography sensors , 1997 .

[36]  Tom Dyakowski,et al.  Study of bubbling and slugging fluidized beds by simulation and ECT , 2006 .

[37]  Maurice Beck,et al.  Tomographic imaging of two-component flow using capacitance sensors , 1989 .

[38]  Wuqiang Yang,et al.  3D imaging with electrical capacitance tomography in cyclone separators , 2006 .

[39]  Robert F. Mudde,et al.  Analysis of chaos in fluidization using electrical capacitance tomography , 1996 .