Accuracy of amplitude-based respiratory gating for PET/CT in irregular respirations

ObjectiveWe evaluated the accuracy of amplitude gating PET (AG-PET) compared with phase gating PET (PG-PET) in relation to respiratory motion patterns based on a phantom analysis.MethodWe used a NEMA IEC body phantom filled with an 18F solution with a 4:1 sphere-to-background radioactivity ratio (12.6 and 2.97 kBq/mL). PET/CT scans were acquired in a motionless and moving state on a Biograph mCT. The respiratory movements were simulated by four different waveform patterns consisting of ideal breathing, breathing with a pause period, breathing with a variable amplitude and breathing with a changing baseline. AG-PET selects the narrow bandwidth containing 20 % of the respiratory cycle. PG-PET was reconstructed with five gates. The image quality was physically assessed using the percent contrast (QH,10mm), background variability (N10mm) recovery coefficient (RC), and sphere volumes.ResultIn regular motion patterns with ideal breathing and breathing with a pause period, the QH,10mm, RC and sphere volumes were not different between AG-PET and PG-PET. In the variable amplitude pattern, the QH,10mm of AG-PET was higher than that of PG-PET (35.8 vs 28.2 %), the RC of AG-PET was higher than that of PG-PET and sphere volume of AG-PET was smaller than that of PG-PET (6.4 vs 8.6 mL). In the changing baseline pattern, the QH,10mm of AG-PET was higher than that of PG-PET (42.4 vs 16.7 %), the RC of AG-PET was higher than that of PG-PET and sphere volume of AG-PET was smaller than that of PG-PET (6.2 vs 9.8 mL). The N10mm did not differ between AG-PET and PG-PET, irrespective of the motion pattern.ConclusionAmplitude gating PET is considered to be more accurate than phase gating PET for examining unstable respiratory motion patterns, such as those involving a variable amplitude or changing baseline.

[1]  Gig S Mageras,et al.  Effect of motion on tracer activity determination in CT attenuation corrected PET images: A lung phantom study. , 2005, Medical physics.

[2]  R. Wahl,et al.  PET-CT: accuracy of PET and CT spatial registration of lung lesions , 2003, European Journal of Nuclear Medicine and Molecular Imaging.

[3]  A comparison of amplitude-based and phase-based positron emission tomography gating algorithms for segmentation of internal target volumes of tumors subject to respiratory motion. , 2013, International journal of radiation oncology, biology, physics.

[4]  H. Dittmann,et al.  Is standardised 18F-FDG uptake value an outcome predictor in patients with stage III non-small cell lung cancer? , 2006, European Journal of Nuclear Medicine and Molecular Imaging.

[5]  W. Oyen,et al.  Role of FDG-PET in the diagnosis and management of lung cancer , 2004, Expert review of anticancer therapy.

[6]  T. Pan,et al.  Factors affecting quantification in PET/CT imaging , 2008 .

[7]  H. Keller,et al.  Quantitative PET Comparing Gated with Nongated Acquisitions Using a NEMA Phantom with Respiratory-Simulated Motion , 2007, Journal of Nuclear Medicine Technology.

[8]  Importance of gated CT acquisition for the quantitative improvement of the gated PET/CT in moving phantom , 2010, Annals of nuclear medicine.

[9]  Accuracy and variability of quantitative measurements using PET with time-of-flight information and resolution modelling , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[10]  O Caselles,et al.  The retrospective binning method improves the consistency of phase binning in respiratory-gated PET/CT , 2012, Physics in medicine and biology.

[11]  P. Lambin,et al.  Identification of residual metabolic-active areas within individual NSCLC tumours using a pre-radiotherapy (18)Fluorodeoxyglucose-PET-CT scan. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  Ross Berbeco,et al.  Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans , 2011, Journal of applied clinical medical physics.

[13]  V Kalff,et al.  The utility of (18)F-FDG PET for suspected recurrent non-small cell lung cancer after potentially curative therapy: impact on management and prognostic stratification. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  Habib Zaidi,et al.  The effect of breathing irregularities on quantitative accuracy of respiratory gated PET∕CT. , 2011, Medical physics.

[15]  C. Ling,et al.  Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. , 2002, Medical physics.

[16]  R L Wahl,et al.  Metastases from non-small cell lung cancer: mediastinal staging in the 1990s--meta-analytic comparison of PET and CT. , 1999, Radiology.

[17]  P. Lambin,et al.  Time trends in the maximal uptake of FDG on PET scan during thoracic radiotherapy. A prospective study in locally advanced non-small cell lung cancer (NSCLC) patients , 2007 .

[18]  A. Pevsner,et al.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Ross Berbeco,et al.  Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images , 2008, Physics in medicine and biology.

[20]  James Hamill,et al.  Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  John W. Clark,et al.  Design and performance of a respiratory amplitude gating device for PET/CT imaging. , 2010, Medical physics.

[22]  John W. Clark,et al.  Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical Evaluation , 2010, Journal of Nuclear Medicine.

[23]  G. V. von Schulthess,et al.  Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. , 2003, The New England journal of medicine.

[24]  C. Dooms,et al.  Positron-emission tomography in prognostic and therapeutic assessment of lung cancer: systematic review. , 2004, The Lancet. Oncology.

[25]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[26]  Cyrill Burger,et al.  PET-CT image co-registration in the thorax: influence of respiration , 2002, European Journal of Nuclear Medicine and Molecular Imaging.