Elimination of electrooxidizable interferant-produced currents in amperometric biosensors.

Electrooxidizable ascorbate, urate, and acetaminophen that interfere with amperometric glucose assays are completely and rapidly oxidized by hydrogen peroxide in a multilayer electrode. The multilayer electrode is composed of an immobilized, but not electrically "wired", horseradish peroxidase (HRP) film coated onto a film of electrically "wired" glucose oxidase (GO). The "wired" enzyme is connected by a redox epoxy network to a vitreous carbon electrode. The current from the electrooxidizable interferants is decreased by their peroxidase-catalyzed preoxidation by a factor of 2500, and the glucose/interferant current ratio is increased 10(3)-fold. Undesired electroreduction of hydrogen peroxide can result when HRP is also "wired" to the electrode. Such unwanted "wiring" is prevented by incorporating an electrically insulating barrier layer between the wired GO film and the HRP film. The hydrogen peroxide necessary for elimination of interferants can be added externally, or when this is not possible, it can be generated in situ by means of a coupled enzyme reaction.

[1]  T. Yao Amperometric determination of glucose in blood serum with a chemically modified enzyme membrane electrode in a continuous flow system , 1983 .

[2]  A. Maehly,et al.  [143] Plant peroxidase☆ , 1955 .

[3]  L. Gorton,et al.  A glucose electrode based on carbon paste chemically modified with a ferrocene-containing siloxane polymer and glucose oxidase, coated with a poly(ester-sulfonic acid) cation-exchanger , 1990 .

[4]  Alexander M. Yacynych,et al.  Electropolymerized films to prevent interferences and electrode fouling in biosensors , 1991 .

[5]  P. Tijssen,et al.  Highly efficient and simple methods for the preparation of peroxidase and active peroxidase-antibody conjugates for enzyme immunoassays. , 1984, Analytical biochemistry.

[6]  T. Tatsuma,et al.  Oxidase/peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acid , 1991 .

[7]  H. Dunford On the function and mechanism of action of peroxidases , 1976 .

[8]  F. Wold [57] Bifunctional reagents. , 1972, Methods in enzymology.

[9]  Y. Okawa,et al.  On-Line Elimination of Electroactive Interferents for Flow-Type Electrochemical Biosensor System , 1991 .

[10]  Hung‐Yuan Cheng,et al.  Voltammetric differentiation of ascorbic acid and dopamine at an electrochemically treated graphite/epoxy electrode , 1982 .

[11]  P. Nakane,et al.  PEROXIDASE-LABELED ANTIBODY A NEW METHOD OF CONJUGATION , 1974, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[12]  M. Ozsoz,et al.  Plant tissue-based amperometric electrode for eliminating ascorbic acid interferences , 1990 .

[13]  Adam Heller,et al.  Electrical Connection of Enzyme Redox Centers to Electrodes , 1992 .

[14]  A. Heller,et al.  L-alpha-glycerophosphate and L-lactate electrodes based on the electrochemical "wiring" of oxidases. , 1992, Analytical chemistry.

[15]  J. Kulys,et al.  BIENZYME SENSORS BASED ON CHEMICALLY MODIFIED ELECTRODES , 1991 .

[16]  Adam Heller,et al.  Elimination of electrooxidizable interferants in glucose electrodes , 1991 .

[17]  A. Chapiro,et al.  Polymérisation du vinylimidazole en masse et en solution , 1988 .

[18]  G. Palleschi,et al.  A study of interferences in glucose measurements in blood by hydrogen peroxide based glucose probes. , 1986, Analytical biochemistry.

[19]  J. Rishpon,et al.  Enzyme electrode for the determination of glucose. , 1981, Analytical chemistry.

[20]  M. Rice,et al.  A new type of enzyme electrode: the ascorbic acid eliminator electrode. , 1982, Life sciences.

[21]  T. Golden,et al.  Poly(4-vinylpyridine)-coated glassy carbon flow detectors. , 1987, Analytical chemistry.

[22]  M. Senda,et al.  Glucose Oxidase-Immobilized Benzoquinone-Mixed Carbon Paste Electrode with Pre-Minigrid , 1985 .

[23]  Adam Heller,et al.  Redox polymer films containing enzymes. 1. A redox-conducting epoxy cement: synthesis, characterization, and electrocatalytic oxidation of hydroquinone , 1991 .

[24]  Adam Heller,et al.  Redox polymer films containing enzymes. 2. Glucose oxidase containing enzyme electrodes , 1991 .

[25]  M. Wilchek,et al.  Immobilization of glycoconjugates by their oligosaccharides: use of hydrazido-derivatized matrices. , 1990, Analytical biochemistry.

[26]  H. Hill,et al.  A method for estimation of hydrogen peroxide based on mediated electron transfer reactions of peroxidases at electrodes , 1986 .

[27]  G. S. Wilson,et al.  Pulsed amperometric detection of glucose in biological fluids at a surface-modified gold electrode. , 1989, Analytical chemistry.