Comparison of SensL and Hamamatsu 4×4 channel SiPM arrays in gamma spectrometry with scintillators

[1]  C. Melcher,et al.  Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[2]  M. Moszynski,et al.  Absolute light output of scintillators , 1997 .

[3]  R. Mirzoyan,et al.  A test of silicon photomultipliers as readout for PET , 2005 .

[4]  Z. Guzik,et al.  TUKAN-an 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface , 2006, IEEE Transactions on Nuclear Science.

[5]  L. A. Filatov,et al.  Status report on silicon photomultiplier development and its applications , 2006 .

[6]  D. Renker Geiger-mode avalanche photodiodes, history, properties and problems , 2006 .

[7]  Paul Lecoq,et al.  Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET , 2007 .

[8]  J. Iwanowska,et al.  Characterization of Scintillators by Modern Photomultipliers—A New Source of Errors , 2010, IEEE Transactions on Nuclear Science.

[9]  D. Renker New developments on photosensors for particle physics , 2009 .

[10]  D. Renker,et al.  Advances in solid state photon detectors , 2009 .

[11]  Rainer Stamen,et al.  Characterisation Studies of Silicon Photomultipliers , 2010, 1003.6071.

[12]  F. Beekman,et al.  A Comprehensive Model of the Response of Silicon Photomultipliers , 2010, IEEE Transactions on Nuclear Science.

[13]  M. Tanaka,et al.  Performance of Multi-Pixel Photon Counters for the T2K near detectors , 2010, 1007.2712.

[14]  S. Vinogradov,et al.  Efficiency of Solid State Photomultipliers in Photon Number Resolution , 2009, IEEE Transactions on Nuclear Science.

[15]  P. Guzowski,et al.  Characterization and Simulation of the Response of Multi Pixel Photon Counters to Low Light Levels , 2011, 1101.1996.

[16]  Characterization of 4×4ch MPPC array in scintillation spectrometry , 2013, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[17]  R. Dorscheid,et al.  Performance evaluation of a prototype Positron Emission Tomography scanner using Digital Photon Counters (DPC) , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[18]  M. Moszynski,et al.  MPPC Array in the Readout of CsI:Tl, LSO:Ce:Ca, LaBr$_{3}\!$:Ce, and BGO Scintillators , 2012, IEEE Transactions on Nuclear Science.

[19]  Craig S. Levin,et al.  Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging , 2013 .

[20]  K. Yamamoto,et al.  Assembly technology of 4-side buttable MPPC , 2013 .

[21]  C. Piemonte,et al.  Characterization of new FBK SiPM technology for visible light detection , 2013 .

[22]  C. Piemonte,et al.  Characterization of the First FBK High-Density Cell Silicon Photomultiplier Technology , 2013, IEEE Transactions on Electron Devices.

[23]  M. Moszynski,et al.  Energy resolution of small scintillation detectors with SiPM light readout , 2013 .

[24]  M. Moszynski,et al.  Characterization of 2 × 2 ch MPPC array over a wide temperature range (−20°C to +21°C) , 2013 .

[25]  Marco Bettiol,et al.  A novel brain PET insert for the MINDView project , 2014, 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[26]  M. Moszynski,et al.  Energy resolution of scintillation detectors , 2016 .

[27]  A. Murari,et al.  High performance detectors for upgraded gamma ray diagnostics for JET DT campaigns , 2016 .

[28]  Antonio J. González,et al.  The MINDView brain PET detector, feasibility study based on SiPM arrays , 2016 .