Selective spectrophotometric determination of TNT using a dicyclohexylamine-based colorimetric sensor.

Because of the extremely heterogeneous distribution of explosives in contaminated soils, on-site colorimetric methods are efficient tools to assess the nature and extent of contamination. To meet the need for rapid and low-cost chemical sensing of explosive traces or residues in soil and post-blast debris, a colorimetric absorption-based sensor for trinitrotoluene (TNT) determination has been developed. The charge-transfer (CT) reagent (dicyclohexylamine, DCHA) is entrapped in a polyvinylchloride (PVC) polymer matrix plasticised with dioctylphtalate (DOP), and moulded into a transparent sensor membrane sliced into test strips capable of sensing TNT showing an absorption maximum at 530 nm when placed in a 1-mm spectrophotometer cell. The sensor gave a linear absorption response to 5-50 mg L(-1) TNT solutions in 30% aqueous acetone with limit of detection (LOD): 3 mg L(-1). The sensor is only affected by tetryl, but not by RDX, pentaerythritoltetranitrate (PETN), dinitrotoluene (DNT), and picric acid. The proposed method was statistically validated for TNT assay against high performance liquid chromatography (HPLC) using a standard sample of Comp B. The developed sensor was relatively resistant to air and water, was of low-cost and high specificity, gave a rapid and reproducible response, and was suitable for field use of TNT determination in both dry and humid soil and groundwater with a portable colorimeter.

[1]  R. Apak,et al.  Selective spectrophotometric determination of TNT in soil and water with dicyclohexylamine extraction , 2005 .

[2]  Joel H. Hildebrand,et al.  A Spectrophotometric Investigation of the Interaction of Iodine with Aromatic Hydrocarbons , 1949 .

[3]  R. Apak,et al.  Selective colorimetric determination of TNT partitioned between an alkaline solution and a strongly basic Dowex 1-X8 anion exchanger. , 2008, Forensic science international.

[4]  W. Seitz,et al.  A clear, amine-containing poly(vinyl chloride) membrane for in situ optical detection of 2,4,6-trinitrotoluene , 1989 .

[5]  G. Absalan,et al.  Constructing a New Optical Sensor for Monitoring Ammonia in Water Samples Using Bis(acetylacetoneethylendiamine)-tributylphosphin Cobalt(III) Tetraphenylborate Complex-Coated Triacetylcellulose , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[6]  V. A. Nefedov,et al.  Detection of trace amounts of explosives and/or explosive related compounds on various surfaces by a new sensing technique/material , 2004 .

[7]  R. Apak,et al.  Selective spectrophotometric determination of trinitrotoluene, trinitrophenol, dinitrophenol and mononitrophenol , 2004 .

[8]  Suman Singh,et al.  Sensors--an effective approach for the detection of explosives. , 2007, Journal of hazardous materials.

[9]  S. Lewis,et al.  A case study in forensic chemistry: The Bali bombings. , 2005, Talanta.

[10]  Kadriye Ertekin,et al.  Fluorescence emission studies of an azlactone derivative embedded in polymer films: An optical sensor for pH measurements , 2000 .

[11]  Paul H. Holloway,et al.  Detection of explosive materials by differential reflection spectroscopy , 2006 .

[12]  Reinhard Niessner,et al.  Dip-and-read test strips for the determination of trinitrotoluene (TNT) in drinking water , 1999 .

[13]  K. E. Russell,et al.  The interaction of aromatic nitro-compounds with bases , 1968 .

[14]  M. B. Denton,et al.  Characterization of the explosive triacetone triperoxide and detection by ion mobility spectrometry. , 2003, Forensic science international.

[15]  J. Yinon,et al.  Modern Methods and Applications in Analysis of Explosives , 1996 .

[16]  R. Drijber,et al.  Rapid spectrophotometric determination of 2,4,6-trinitrotoluene in a Pseudomonas enzyme assay. , 2000, Journal of microbiological methods.

[17]  H. Beller,et al.  Use of liquid chromatography/tandem mass spectrometry to detect distinctive indicators of in situ RDX transformation in contaminated groundwater. , 2002, Environmental science & technology.

[18]  M. Walsh,et al.  Development of field screening methods for TNT, 2,4-DNT and RDX in soil. , 1992, Talanta.

[19]  R. S. Mulliken Molecular Compounds and their Spectra. II , 1952 .

[20]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[21]  C. F. Bauer,et al.  Reversed-phase high-performance liquid chromatographic determination of nitroorganics in munitions wastewater , 1986 .

[22]  D. Fine,et al.  Picogram Analyses of Explosive Residues Using the Thermal Energy Analyzer (TEA , 1984 .

[23]  R. Apak,et al.  Development of an optical fibre reflectance sensor for p-aminophenol detection based on immobilised bis-8-hydroxyquinoline. , 2008, Talanta.

[24]  J. Miller,et al.  Statistics for Analytical Chemistry , 1993 .

[25]  Peter Kolla,et al.  The Application of Analytical Methods to the Detection of Hidden Explosives and Explosive Devices , 1997 .