Evaluating the performance of a large borehole ground source heat pump for greenhouses in northern Japan

The objective of this study was to use both field data and a numerical simulation to examine the long-term performance and environmental effects of a large GSHP (ground source heat pump) system that heats and cools industrial greenhouses in a cold region. A large vertical GSHP system was installed in the city of Akabira in the north of Hokkaido, Japan to provide heating and cooling for 12 greenhouses. The system has a maximum capacity of 640 and 648 kW for heating and cooling, respectively. The system was monitored and analyzed from Oct. 2010 through May 2011. The system had a COP (coefficient of performance) of 3.0 and SCOP (system coefficient of performance) of 2.7. The average heat extraction rate of the system was approximately 27.7 W/m. In addition, the ground temperature at a depth of 40 m decreased from approximately 7.8 °C to 0 °C after 8 months of operation. A numerical model of the system was developed in FEFLOW to predict its future behavior under conditions where the demand for heating surpasses the demand for cooling. The simulation results suggest that the system could maintain the heat exchange rate for several years without significantly compromising its performance. The risk of operating the system under unbalanced heating and cooling loads was addressed via case studies. Groundwater flow decreases the risk of operating the system when the heat extraction was much higher or lower than the heat injection.

[1]  Stefanie Hellweg,et al.  Is it only CO2 that matters? A life cycle perspective on shallow geothermal systems , 2010 .

[2]  D. Nutter,et al.  A Ground Resistance for Vertical Bore Heat Exchangers With Groundwater Flow , 2003 .

[3]  C. K. Lee,et al.  A modified multi-ground-layer model for borehole ground heat exchangers with an inhomogeneous groundwater flow , 2012 .

[4]  James G. Berryman,et al.  Thermal conductivity of porous media , 2004 .

[5]  S. Rees,et al.  A preliminary assessment of the effects of groundwater flow on closed-loop ground source heat pump systems , 2000 .

[6]  P. Blum,et al.  Evaluating the influence of thermal dispersion on temperature plumes from geothermal systems using analytical solutions , 2011 .

[7]  H. Paksoy,et al.  Ground water level influence on thermal response test in Adana, Turkey , 2008 .

[8]  Yang Yao,et al.  A study on the performance of a geothermal heat exchanger under coupled heat conduction and groundwater advection , 2007 .

[9]  W. Woodside,et al.  Thermal Conductivity of Porous Media. II. Consolidated Rocks , 1961 .

[10]  A. O'connell,et al.  New analytical solution for sizing vertical borehole ground heat exchangers in environments with significant groundwater flow: Parameter estimation from thermal response test data , 2011, HVAC&R Research.

[11]  Michael de Paly,et al.  Optimization of energy extraction for vertical closed-loop geothermal systems considering groundwater flow , 2013 .

[12]  C K Lee,et al.  EFFECTS OF GROUNDWATER FLOW DIRECTION ON PERFORMANCE OF GROUND HEAT EXCHANGER BOREFIELD IN GEOTHERMAL HEAT PUMP SYSTEMS USING 3-D FINITE DIFFERENCE METHOD , 2007 .

[13]  Rui Fan,et al.  Theoretical study on the performance of an integrated ground-source heat pump system in a whole year , 2008 .

[14]  P. Blum,et al.  Analytical approach to groundwater-influenced thermal response tests of grouted borehole heat exchangers , 2013 .

[15]  Z. Fang,et al.  Heat transfer in ground heat exchangers with groundwater advection , 2004 .

[16]  K. Zhu,et al.  A moving finite line source model to simulate borehole heat exchangers with groundwater advection , 2011 .

[17]  Enzo Zanchini,et al.  Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow , 2012 .