Study on Damage of a Floating Roof-Type Oil Storage Tank due to Thermal Stress
暂无分享,去创建一个
Several cracks were found on some actual floating roofs of a crude oil tank in the oil refinery located in southern Japan. We assumed that one of reasons would be due to thermal stress caused by temperature changes during the day. In order to consider whether the thermal stress could the cause damages on the floating roof, strain and temperature were measured on the actual floating roof by using optical fiber gauges. Furthermore, thermal stress analysis was carried out as effective analysis.
[1] Shinsaku Zama,et al. Long-period Strong Ground Motion and Damage to Oil Storage Tanks Due to the 2003 Tokachi-oki Earthquake , 2004 .
[2] Shinsaku Zama,et al. Study on the damage of the floating roof due to thermal stress , 2010, 2010 International Conference on Mechanical and Electrical Technology.