Quantum-noise-limited interferometric phase measurements.

Two schemes for interferometric optical phase measurement, with sensitivity limited only by quantum noise in the light, are analyzed. Direct detection is applicable to signals at modulation frequencies away from the technical noise of the light, so that quantum noise dominates the measurement. Alternatively signals otherwise obscured by classical optical noise may be recovered with a phase-modulation technique that shifts the signals to a quantum-noise-limited region of the photocurrent spectrum. The analysis is tested experimentally by using a polarimetric electric-field sensor. In the direct-detection scheme quantum-noise-limited performance produced a phase sensitivity of 0.25 µrad. The indirect scheme allowed subkilohertz signals to be extracted from classical noise 67 dB greater with sensitivity approaching the quantum noise limit.

[1]  V. Braginskii,et al.  Quantum-mechanical limitations in macroscopic experiments and modern experimental technique , 1975 .

[2]  H. Bachor,et al.  Practical Implications of Quantum Noise , 1990 .

[3]  B. J. Meers,et al.  Recycling in laser-interferometric gravitational-wave detectors. , 1988, Physical review. D, Particles and fields.

[4]  G. Leuchs,et al.  Applying squeezed states to nonideal interferometers , 1987 .

[5]  R. J. Sandeman,et al.  Laser Interferometer Gravitational-wave Observatories: An Overview , 1990 .

[6]  H. Bachor,et al.  Quantum noise — A limit in photodetection , 1989 .

[7]  R. Drever Laser interferometer gravitational radiation detectors , 1983 .

[8]  H. K. Heinrich,et al.  Noninvasive sheet charge density probe for integrated silicon devices , 1986 .

[9]  Winkler,et al.  Nonstationary shot noise and its effect on the sensitivity of interferometers. , 1991, Physical review. A, Atomic, molecular, and optical physics.

[10]  R. Loudon Quantum Limit on the Michelson Interferometer used for Gravitational-Wave Detection , 1981 .

[11]  Gerd Leuchs,et al.  Squeezed States for Interferometric Gravitational-wave Detectors , 1987 .

[12]  V. Sandberg,et al.  ON THE MEASUREMENT OF A WEAK CLASSICAL FORCE COUPLED TO A QUANTUM MECHANICAL OSCILLATOR. I. ISSUES OF PRINCIPLE , 1980 .

[13]  Meers,et al.  Modulation, signal, and quantum noise in interferometers. , 1991, Physical review. A, Atomic, molecular, and optical physics.

[14]  David M. Bloom,et al.  Picosecond optical sampling of GaAs integrated circuits , 1988 .

[15]  C. Caves Quantum Mechanical Noise in an Interferometer , 1981 .

[16]  Vinet,et al.  Optimization of long-baseline optical interferometers for gravitational-wave detection. , 1988, Physical review. D, Particles and fields.

[17]  N. L. MacKenzie,et al.  The detection of gravitational waves: The stabilisation of lasers for interferometric gravitational wave detectors , 1991 .