Biocompatibility of β-stabilizing elements of titanium alloys

Abstract In comparison to the presently used α+β titanium alloys for biomedical applications, β-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with β-stabilizing properties in titanium alloys are suitable for biomaterial applications—corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for β- and near β-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (α=0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium–tantalum, titanium, zirconium–aluminium–316 L–molybdenum.

[1]  J. Scully,et al.  Corrosion and Passivity of Ti-13% Nb-13% Zr in Comparison to Other Biomedical Implant Alloys , 1997 .

[2]  H. M. Kim,et al.  Bonding of alkali- and heat-treated tantalum implants to bone. , 2000, Journal of biomedical materials research.

[3]  L. Schaeffer,et al.  Dental Implants of TiTa30 Produced by Powder Technology , 1998 .

[4]  B. Kasemo,et al.  Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium , 1997, Journal of materials science. Materials in medicine.

[5]  H. Doi,et al.  Influence of aging heat treatment on mechanical properties of biomedical Ti–Zr based ternary alloys containing niobium , 1998, Journal of materials science. Materials in medicine.

[6]  Marcus Textor,et al.  Titanium in Medicine : material science, surface science, engineering, biological responses and medical applications , 2001 .

[7]  M. Niinomi,et al.  Corrosion wear fracture of new β type biomedical titanium alloys , 1999 .

[8]  D. Howie,et al.  In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium. , 1997, The Journal of bone and joint surgery. British volume.

[9]  R. Messer,et al.  Effects of metallic ion toxicity on human gingival fibroblasts morphology. , 1999, Biomaterials.

[10]  G. Winter,et al.  Evaluation of biomaterials , 1980 .

[11]  A. Forlino,et al.  Evaluation of the TiMo12Zr6Fe2 alloy for orthopaedic implants: in vitro biocompatibility study by using primary human fibroblasts and osteoblasts. , 2002, Biomaterials.

[12]  K. Wapner,et al.  Implications of metallic corrosion in total knee arthroplasty. , 1991, Clinical orthopaedics and related research.

[13]  R. Messer,et al.  Evaluations of metabolic activities as biocompatibility tools: a study of individual ions' effects on fibroblasts. , 1999, Dental materials : official publication of the Academy of Dental Materials.

[14]  D. Williams,et al.  The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions. , 1999, Biomaterials.

[15]  H. M. Kim,et al.  Enhancement of bone-bonding strengths of titanium alloy implants by alkali and heat treatments. , 1999, Journal of biomedical materials research.

[16]  M Semlitsch,et al.  Titanium-Aluminium-Niobium Alloy, Development for Biocompatible, High Strength Surgical Implants - Titan-Aluminium-Niob-Legierung, entwickelt für körperverträgliche, hochfeste Implantate in der Chirurgie , 1985, Biomedizinische Technik. Biomedical engineering.

[17]  Jef A. Helsen,et al.  Metals as Biomaterials , 1998 .

[18]  A. D. McQuillan,et al.  The science technology and application of titanium , 1971 .

[19]  D. Scharnweber,et al.  Electrochemical behavior of titanium-based materials – are there relations to biocompatibility? , 2002, Journal of materials science. Materials in medicine.

[20]  M. Metikoš-huković,et al.  The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution. , 2003, Biomaterials.

[21]  R. Streicher,et al.  Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy. , 1992, Biomaterials.

[22]  E. Collings,et al.  Materials Properties Handbook: Titanium Alloys , 1994 .

[23]  M. Semlitsch Titanium alloys for hip joint replacements , 1987 .

[24]  P. Tengvall,et al.  Ellipsometric in vitro studies on blood plasma and serum adsorption to zirconium. , 2001, Journal of biomedical materials research.

[25]  S. Perren,et al.  Comparison of the tissue reaction to implants made of a beta titanium alloy and pure titanium. Experimental study on rabbits , 1994 .

[26]  H. Duschner,et al.  Characterization of thermal and anodic oxide layers on β- and on near-β-titanium alloys for biomedical application , 2003, International Journal of Materials Research - Zeitschrift für Metallkunde.

[27]  G. Niklasson,et al.  Electrical Properties of ZrO2 Thin Films , 2002 .

[28]  Christoph Fink,et al.  Biocompatibility of corroding tungsten coils: in vitro assessment of degradation kinetics and cytotoxicity on human cells. , 2003, Biomaterials.

[29]  L. Murr,et al.  Evaluation of mechanical and corrosion biocompatibility of TiTa alloys , 2001, Journal of materials science. Materials in medicine.

[30]  Y. Okazaki,et al.  New Ti Alloy without Al and V for Medical Implants , 2000 .

[31]  T Albrektsson,et al.  Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium. , 1990, Biomaterials.

[32]  J. Black Does corrosion matter? , 1988, The Journal of bone and joint surgery. British volume.