On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions

Abstract A common effective method to reduce the seismic response of liquid storage tanks is to isolate them at base using base-isolation systems. It has been observed that in many earthquakes, the foregoing systems significantly affect on the whole system response reduction. However, in exceptional cases of excitation by long-period shaking, the base-isolation systems could have adverse effects. Such earthquakes could cause tank damage due to excessive liquid sloshing. Therefore, the numerical seismic response of liquid storage tanks isolated by bilinear hysteretic bearing elements is investigated under long-period ground motions in this research. For this purpose, finite shell elements for the tank structure and boundary elements for the liquid region are employed. Subsequently, fluid–structure equations of motion are coupled with governing equation of base-isolation system, to represent the whole system behavior. The governing equations of motion of the whole system are solved by an iterative and step-by-step algorithm to evaluate the response of the whole system to the horizontal component of three ground motions. The variations of seismic shear forces, liquid sloshing heights, and tank wall radial displacements are plotted under various system parameters such as the tank geometry aspect ratio (height to radius), and the flexibility of the isolation system, to critically examine the effects of various system parameters on the effectiveness of the base-isolation systems against long-period ground motions. From these analyses, it may be concluded that with the installation of this type of base-isolation system in liquid tanks, the dynamic response of tanks during seismic ground motions can be considerably reduced. Moreover, in the special case of long-period ground motions, the seismic response of base-isolated tanks may be controlled by the isolation system only at particular conditions of slender and broad tanks. For the case of medium tanks, remarkable attentions would be required to be devoted to the design of base-isolation systems expected to experience long-period ground motions.

[1]  Moon Kyum Kim,et al.  Seismic analysis of base-isolated liquid storage tanks using the BE–FE–BE coupling technique , 2002 .

[2]  K. Koketsu,et al.  A seismological overview of long-period ground motion , 2008 .

[3]  R. S. Jangid,et al.  Seismic response of liquid storage tanks isolated by sliding bearings , 2002 .

[4]  Akira Niwa,et al.  Buckling of cylindrical liquid-storage tanks under earthquake loading , 1982 .

[5]  N. Khaji,et al.  A coupled BE–FE study for evaluation of seismically isolated cylindrical liquid storage tanks considering fluid–structure interaction , 2009 .

[6]  Emilio Rosenblueth,et al.  Fundamentals of earthquake engineering , 1971 .

[7]  Moon Kyum Kim,et al.  Seismic response of base-isolated liquid storage tanks considering fluid-structure-soil interaction in time domain , 2004 .

[8]  R. S. Jangid Optimum friction pendulum system for near-fault motions , 2005 .

[9]  Bo Liang,et al.  Vibration studies of base-isolated liquid storage tanks , 1994 .

[10]  Yu Tang,et al.  Rocking Response of Liquid Storage Tanks , 1987 .

[11]  Praveen K. Malhotra New method for seismic isolation of liquid-storage tanks , 1997 .

[12]  Medhat A. Haroun Vibration studies and tests of liquid storage tanks , 1983 .

[13]  Carlos Alberto Brebbia,et al.  Boundary Elements: An Introductory Course , 1989 .

[14]  R. S. Jangid,et al.  Variable friction pendulum system for seismic isolation of liquid storage tanks , 2008 .

[15]  George C. Manos,et al.  Tank damage during the may 1983 coalinga earthquake , 1985 .

[16]  R. S. Jangid,et al.  Seismic behaviour of base-isolated buildings : a state-of-the-art review , 1995 .

[17]  J. Z. Zhu,et al.  The finite element method , 1977 .

[18]  Praveen K. Malhotra,et al.  METHOD FOR SEISMIC BASE ISOLATION OF LIQUID-STORAGE TANKS. TECHNICAL NOTE , 1997 .

[19]  J. Kelly,et al.  Shake Table Test of Cylindrical Water Tanks in Base-Isolated Structures , 1990 .

[20]  Medhat A. Haroun,et al.  Dynamic Characteristics of Liquid Storage Tanks , 1982 .

[21]  Medhat A. Haroun,et al.  Model for flexible tanks undergoing rocking , 1985 .

[22]  G. Housner The dynamic behavior of water tanks , 1963 .

[23]  James M. Kelly,et al.  Aseismic base isolation: review and bibliography , 1986 .

[24]  James M. Kelly,et al.  Earthquake-Resistant Design with Rubber , 1993 .

[25]  Marvin W. Halling,et al.  Near-Source Ground Motion and its Effects on Flexible Buildings , 1995 .

[26]  R. S. Jangid,et al.  Response of base-isolated liquid storage tanks to near-fault motions , 2006 .

[27]  George C. Manos Evaluation of the earthquake performance of anchored wine tanks during the San Juan, Argentina, 1977 earthquakexs , 1991 .

[28]  R. S. Jangid,et al.  Seismic analysis of base-isolated liquid storage tanks , 2004 .