Optimal Location of FCL
暂无分享,去创建一个
[1] Magne Runde,et al. Fault Current Limiters , 2002 .
[2] Jen-Hao Teng,et al. Optimum Fault Current Limiter Placement , 2007, 2007 International Conference on Intelligent Systems Applications to Power Systems.
[3] Mehrdad Tarafdar Hagh,et al. Parallel-Resonance-Type Fault Current Limiter , 2013, IEEE Transactions on Industrial Electronics.
[4] Hossein Askarian Abyaneh,et al. A novel method for optimum fault current limiter placement using particle swarm optimization algorithm , 2015 .
[5] A. Mohamed,et al. Performance evaluation of solid state fault current limiters in electric distribution system , 2003, Proceedings. Student Conference on Research and Development, 2003. SCORED 2003..
[6] Peng Liu,et al. The research of resonant fault current limiter based on electromagnetic transient simulation , 2012, IEEE PES Innovative Smart Grid Technologies.
[7] Yasunori Mitani,et al. Optimal location assignment and design of superconducting fault current limiters applied to loop power systems , 2003 .
[8] M.M.R. Ahmed. Comparison of the performance of two solid state fault current limiters in the distribution network , 2008 .
[9] Jen-Hao Teng,et al. Optimum fault current limiter placement with search space reduction technique , 2010 .
[10] F. Katebi,et al. Fault Current Limiter Optimal Placement by Harmony Search Algorithm , 2013 .
[11] C. S. Chang,et al. Designs synthesis of resonant fault current limiter for voltage sag mitigation and current limitation , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).
[12] Wei Lee Woon,et al. Optimal Protection Coordination for Microgrids With Grid-Connected and Islanded Capability , 2012 .
[13] Yanli Zhang,et al. A novel IGCT-based Half-controlled Bridge Type Fault Current Limiter , 2006, 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference.
[14] Mustafa Bagriyanik,et al. The Effect of Fault Current Limiters on Distribution Systems with Wind Turbine Generators , 2013 .
[15] Sung-Yul Kim,et al. SFCL Location Selection Considering Reliability Indices , 2010 .
[16] A. Elmitwally,et al. Optimal Application of Fault Current Limiters for Assuring Overcurrent Relays Coordination with Distributed Generations , 2016 .
[17] Bala Venkatesh,et al. Optimal Location and Sizing of Fault Current Limiters in Mesh Networks Using Iterative Mixed Integer Nonlinear Programming , 2016, IEEE Transactions on Power Systems.
[18] Mostafa Barzegari,et al. Optimal coordination of directional overcurrent relays in the presence of distributed generation using FCLs , 2010, 2010 IEEE International Energy Conference.
[19] A. Elmitwally,et al. Optimal allocation of fault current limiters for sustaining overcurrent relays coordination in a power system with distributed generation , 2015 .
[20] Gang Chen,et al. A new proposal for solid state fault current limiter and its control strategies , 2004, IEEE Power Engineering Society General Meeting, 2004..
[21] H. Schmitt,et al. Fault current limiters report on the activities of CIGRE WG A3.16 , 2006, 2006 IEEE Power Engineering Society General Meeting.
[22] Hamid Javadi. Fault current limiter using a series impedance combined with bus sectionalizing circuit breaker , 2011 .
[23] Y.S. Cha,et al. Analysis of a passive superconducting fault current limiter , 1998, IEEE Transactions on Applied Superconductivity.
[24] D. Shein,et al. The influence of fault current limiting in power systems on transient recovery voltage , 1996, Proceedings of 19th Convention of Electrical and Electronics Engineers in Israel.
[25] M. Nagata,et al. FCL location selection in large scale power system , 2001 .
[26] K. Arai,et al. Fundamental Characteristics of Superconducting Fault Current Limiter Using LC Resonance Circuit , 2006, IEEE Transactions on Applied Superconductivity.
[27] M.-R. Haghifam,et al. Cost reduction of distribution network protection in presence of distributed generation using optimized fault current limiter allocation , 2012 .
[28] S. Quaia,et al. Reducing voltage sags through fault current limitation , 2001 .
[29] A. R. Sedighi,et al. Optimal Placement and Sizing of Fault Current Limiter in a Real Network: a Case Study , 2015 .