Uniform fat suppression in hands and feet through the use of two-point Dixon chemical shift MR imaging.

PURPOSE To assess the potential of two-point Dixon chemical shift magnetic resonance imaging to achieve uniform fat suppression in the distal parts of the extremities. MATERIALS AND METHODS Two-point Dixon chemical shift imaging was performed in 31 consecutive patients clinically suspected to have bone marrow disease. In some patients, Dixon studies were performed before and after the intravenous administration of gadopentetate dimeglumine, and in some patients follow-up examinations were performed, for a total of 64 studies. Areas of interest were the hand, wrist, foot, ankle, and lower leg. There was a special interest in the neuropathic foot and osteomyelitis. The uniformity of fat suppression in the entire field of view, the frequency of displacement artifacts, and the applicability of the technique in routine patient treatment were evaluated. RESULTS In 64 (100%) Dixon studies, uniform fat suppression was achieved. In 59 (92%) studies, there were no displacement artifacts. In five (8%) studies, displacement artifacts occurred; however, in only one (2%) study did they severely hamper the reading. Thus, in 63 (98%) studies, adequate diagnostic quality was obtained. CONCLUSION Two-point Dixon chemical shift imaging is a good technique for achieving uniform fat suppression in the distal parts of the extremities. Because the frequency of displacement artifacts is low, the technique is applicable in a routine clinical setting.

[1]  W A Murphy,et al.  Fatty infiltration of the liver: demonstration by proton spectroscopic imaging. Preliminary observations. , 1984, Radiology.

[2]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[3]  J Listerud,et al.  Combined chemical-shift and phase-selective imaging for fat suppression: theory and initial clinical experience. , 1991, Radiology.

[4]  W. Yuh,et al.  Abnormalities of the foot in patients with diabetes mellitus: findings on MR imaging. , 1991, AJR. American journal of roentgenology.

[5]  F. Hoffer,et al.  Osteomyelitis in children: gadolinium-enhanced MR imaging. , 1992, Radiology.

[6]  D. Mitchell,et al.  Benign adrenocortical masses: diagnosis with chemical shift MR imaging. , 1992, Radiology.

[7]  W. Hanafee,et al.  Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck. , 1992, AJNR. American journal of neuroradiology.

[8]  H. Ishizaka,et al.  Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging. , 1993, Radiology.

[9]  D. Mitchell,et al.  Diagnosis of osteomyelitis: utility of fat-suppressed contrast-enhanced MR imaging. , 1993, Radiology.

[10]  W. J. Lorenz,et al.  MR imaging of fat-containing tissues: valuation of two quantitative imaging techniques in comparison with localized proton spectroscopy. , 1993, Magnetic resonance imaging.

[11]  S. Mirowitz Fast scanning and fat-suppression MR imaging of musculoskeletal disorders. , 1993, AJR. American journal of roentgenology.

[12]  J. B. Kneeland,et al.  MR imaging of the musculoskeletal system: technical considerations for enhancing image quality and diagnostic yield. , 1994, AJR. American journal of roentgenology.

[13]  C G Peterfy,et al.  Recent advances in magnetic resonance imaging of the musculoskeletal system. , 1994, Radiologic clinics of North America.

[14]  V. Ladam-Marcus,et al.  MR imaging of osteomyelitis and neuropathic osteoarthropathy in the feet of diabetics. , 1996, Radiographics : a review publication of the Radiological Society of North America, Inc.

[15]  I. Francis,et al.  Adrenal radiology: distinguishing benign from malignant adrenal masses. , 1996, AJR. American journal of roentgenology.

[16]  Peterfy,et al.  Dedicated extremity MR imaging: An emerging technology , 1998, Magnetic resonance imaging clinics of North America.