Research on Flow Resistance Characteristics with Different Window/Door Opening Angles

Airflow rate through buildings can depend in part on the degree of opening of various doors and windows. A better understanding of flow resistance characteristics under different window/door opening angles can help us better predict the airflow rate in buildings. Additionally, better understanding of flow characteristics can enable better natural ventilation control strategies. We examined the discharge coefficient and loss coefficient of a window/door with differing degrees of opening through both wind tunnel testing and computational fluid dynamic (CFD) simulation. We were able to match simulated and tested pressure differences across the opening under certain airflow rates. The simulated results for discharge coefficient and loss coefficient matched well with the test data. Results showed that discharge coefficient increases with increasing degree of window/door opening, while the loss coefficient decreases. Additionally, the discharge coefficient Cd and loss coefficient ζ are all power-correlated with the window/door opening angle θ. The loss coefficient decreases sharply with the increasing of the window/door opening angle θ when θ is smaller than 30° and plateaus when θ is larger than 30°, thus showing that doors and windows do not need to be fully open for optimal natural ventilatio

[1]  Y.-P. Lin,et al.  THE INFLUENCE OF POROUS SCREENS ON NATURAL VENTILATION IN A DWELLING UNIT , 2005 .

[2]  J. Busch A tale of two populations: thermal comfort in air-conditioned and naturally ventilated offices in Thailand , 1992 .

[3]  G. Bot Greenhouse climate: from physical processes to a dynamic model , 1983 .

[4]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[5]  L. Richardson The Approximate Arithmetical Solution by Finite Differences of Physical Problems Involving Differential Equations, with an Application to the Stresses in a Masonry Dam , 1911 .

[6]  Daniel Chung,et al.  Well-Posed Models of Porous Buildings for Macroscopic Ventilation Analysis> , 2006 .

[7]  Ursula Eicker,et al.  Limits and potentials of office building climatisation with ambient air , 2006 .

[8]  P. Roache Perspective: A Method for Uniform Reporting of Grid Refinement Studies , 1994 .

[9]  Bin Zhao,et al.  Cooking generated particles’ impact on indoor air quality of university cafeteria , 2010 .

[10]  Qingyan Chen COMPARISON OF DIFFERENT k-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS , 1995 .

[11]  André De Herde,et al.  Design of low energy office buildings , 2003 .

[12]  Per Heiselberg,et al.  Characteristics of Airflow from Open Windows , 2001 .

[13]  C A Pickering,et al.  The sick building syndrome: prevalence studies. , 1984, British medical journal.

[14]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[15]  P. Linden THE FLUID MECHANICS OF NATURAL VENTILATION , 1999 .

[16]  Shigeki Nishizawa,et al.  Wind Pressure and Air Flow in a Full-Scale Building Model under Cross Ventilation , 2004 .

[17]  Takashi Kurabuchi,et al.  Study on airflow characteristics inside and outside a cross-ventilation model, and ventilation flow rates using wind tunnel experiments , 2001 .

[18]  Nadia Ghrab-Morcos,et al.  Modeling coupled heat transfer and air flow in a partitioned building with a zonal model: Application to the winter thermal comfort , 2009 .

[19]  Chia-Ren Chu,et al.  The loss factors of building openings for wind-driven ventilation , 2010 .

[20]  T. Frank,et al.  Climate change impacts on building heating and cooling energy demand in Switzerland , 2005 .