Effect of operational and design parameters on performance of pilot-scale horizontal subsurface flow constructed wetlands treating university campus wastewater

Three horizontal subsurface flow (HSF) pilot-scale constructed wetland (CW) units operated for 3 years treating municipal wastewater originating from a university campus. The main objective of the study was the evaluation of the performance of these systems under several operational, design, and climatic conditions. Several parameters and factors were investigated, including the influence of temperature, vegetation, and hydraulic residence time. The results were compared to those of a previous study conducted in the same pilot-scale units and under the same operational conditions where synthetic municipal wastewater was used. Results show the satisfying overall performance of the CW units. Performance seems to be influenced by vegetation, temperature, and hydraulic residence time (HRT). The planted units produced better results than the unplanted one while, generally, all units operated better under warmer conditions. In addition, longer HRTs contributed to higher removal efficiencies. Finally, the systems showed higher removal efficiencies in the previous study (synthetic wastewater) regarding organic matter removal, while for the other pollutants, the present study (real wastewater) showed higher or comparable performance in most cases and especially in the planted units. The study also shows the overall good, continuous, and long-term operation of CW systems, since these systems operate for about 13 years.

[1]  G. Herath,et al.  Impact of the hydraulic loading rate on pollutants removal in tropical horizontal subsurface flow constructed wetlands , 2013 .

[2]  Alexandros Stefanakis,et al.  Effect of wastewater step-feeding on removal efficiency of pilot-scale horizontal subsurface flow constructed wetlands , 2011 .

[3]  Pd Nsimama CORRELATION BETWEEN MORPHOLOGICAL, OPTICAL AND ELECTRICAL PROPERTIES OF ZnO:AL/ZnO DOUBLE LAYERS AND THE Cu(In,Ga)Se2 SOLAR CELL EFFICIENCIES , 2012 .

[4]  Enas M. Abou-Taleb,et al.  Municipal wastewater treatment in horizontal and vertical flows constructed wetlands , 2013 .

[5]  Vassilios A Tsihrintzis,et al.  Environmental footprint of constructed wetlands treating wastewater , 2015, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[6]  Jan Vymazal,et al.  Long-term performance of constructed wetlands with horizontal sub-surface flow: Ten case studies from the Czech Republic , 2011 .

[7]  A N Angelakis,et al.  Performance and Cost Comparison of a FWS and a VSF Constructed Wetland System , 2007, Environmental technology.

[8]  R. D. Tripathi,et al.  Seasonal applicability of horizontal sub-surface flow constructed wetland for trace elements and nutrient removal from urban wastes to conserve Ganga River water quality at Haridwar, India , 2015 .

[9]  M. Moeder,et al.  Removal of selected organic micropollutants in planted and unplanted pilot-scale horizontal flow constructed wetlands under conditions of high organic load , 2014 .

[10]  Hai Liu,et al.  A review on the sustainability of constructed wetlands for wastewater treatment: Design and operation. , 2015, Bioresource technology.

[11]  S. Tan,et al.  Application of constructed wetlands for wastewater treatment in tropical and subtropical regions (2000-2013). , 2015, Journal of environmental sciences.

[12]  Joan García,et al.  Contaminant removal efficiency depending on primary treatment and operational strategy in horizontal subsurface flow treatment wetlands , 2011 .

[13]  D P L Rousseau,et al.  Reactive transport simulation in a tropical horizontal subsurface flow constructed wetland treating domestic wastewater. , 2013, The Science of the total environment.

[14]  T. Fletcher,et al.  Nitrogen removal in constructed wetland systems , 2009 .

[15]  Rafael Mujeriego,et al.  Effect of key design parameters on the efficiency of horizontal subsurface flow constructed wetlands , 2005 .

[16]  Víctor Matamoros,et al.  Contaminant Removal Processes in Subsurface-Flow Constructed Wetlands: A Review , 2010 .

[17]  E. Bécares,et al.  Comparison of interannual removal variation of various constructed wetland types. , 2012, The Science of the total environment.

[18]  Jaume Puigagut,et al.  Solids accumulation in six full-scale subsurface flow constructed wetlands. , 2007, Water research.

[19]  P Kuschk,et al.  Influence of the redox condition dynamics on the removal efficiency of a laboratory-scale constructed wetland. , 2005, Water research.

[20]  Sherwood C. Reed,et al.  Natural Wastewater Treatment Systems , 2000 .

[21]  Jaume Puigagut,et al.  Subsurface-flow constructed wetlands in Spain for the sanitation of small communities: A comparative study , 2007 .

[22]  Le Anh Tuan,et al.  Kinetics of pollutant removal from domestic wastewater in a tropical horizontal subsurface flow constructed wetland system: Effects of hydraulic loading rate , 2010 .

[23]  T. Tuttolomondo,et al.  Effects of plant species in a horizontal subsurface flow constructed wetland – phytoremediation of treated urban wastewater with Cyperus alternifolius L. and Typha latifolia L. in the West of Sicily (Italy) , 2013 .

[24]  Jan Vymazal,et al.  The use of sub-surface constructed wetlands for wastewater treatment in the Czech Republic: 10 years experience , 2002 .

[25]  Jian Huang,et al.  Nitrogen removal in constructed wetlands employed to treat domestic wastewater. , 2000 .

[26]  Thammarat Koottatep,et al.  TREATMENT OF DOMESTIC WASTEWATER IN TROPICAL SUBSURFACE FLOW CONSTRUCTED WETLANDS PLANTED WITH CANNA AND HELICONIA , 2009 .

[27]  Vassilios A Tsihrintzis,et al.  Construction and operation costs of constructed wetlands treating wastewater. , 2014, Water science and technology : a journal of the International Association on Water Pollution Research.

[28]  M. Wong,et al.  Nitrogen and phosphate mass balance in a sub-surface flow constructed wetland for treating municipal wastewater , 2008 .

[29]  K. Njau,et al.  PERFORMANCE OF SUBSURFACE FLOW CONSTRUCTED WETLAND FOR DOMESTIC WASTEWATER TREATMENT , 2013 .

[30]  J. Anda,et al.  Treatment of domestic wastewater and production of commercial flowers in vertical and horizontal subsurface-flow constructed wetlands , 2009 .

[31]  Esther Llorens,et al.  Practical method based on saturated hydraulic conductivity used to assess clogging in subsurface flow constructed wetlands , 2009 .

[32]  Ying Li,et al.  Enhancement of nitrogen removal in towery hybrid constructed wetland to treat domestic wastewater for small rural communities , 2009 .

[33]  V. Tsihrintzis,et al.  Evaluation of evapotranspiration in small on-site HSF constructed wetlands , 2012, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[34]  T. Manios,et al.  Removal of Total Suspended Solids from Wastewater in Constructed Horizontal Flow Subsurface Wetlands , 2003, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[35]  Vassilios A. Tsihrintzis,et al.  Effect of temperature, HRT, vegetation and porous media on removal efficiency of pilot-scale horizontal subsurface flow constructed wetlands , 2007 .

[36]  V. Tsihrintzis,et al.  Municipal wastewater treatment using constructed wetlands , 2014 .

[37]  V. Tsihrintzis,et al.  Constructed wetlands for wastewater and activated sludge treatment in north Greece: a review. , 2010, Water science and technology : a journal of the International Association on Water Pollution Research.

[38]  Soon Keat Tan,et al.  Application of constructed wetlands for wastewater treatment in developing countries--a review of recent developments (2000-2013). , 2014, Journal of environmental management.

[39]  Guangzhi Sun,et al.  A review on nitrogen and organics removal mechanisms in subsurface flow constructed wetlands: dependency on environmental parameters, operating conditions and supporting media. , 2012, Journal of environmental management.

[40]  V. Tsihrintzis,et al.  Effluent quality improvement of two pilot-scale, horizontal subsurface flow constructed wetlands using natural zeolite (clinoptilolite) , 2009 .

[41]  Vassilios A. Tsihrintzis,et al.  Effect of outlet water level raising and effluent recirculation on removal efficiency of pilot-scale, horizontal subsurface flow constructed wetlands , 2008 .

[42]  D. Adler Wastewater Treatment In Constructed Wetlands With Horizontal Sub Surface Flow , 2016 .

[43]  Vassilios A Tsihrintzis,et al.  Performance and modeling of a vertical flow constructed wetland–maturation pond system , 2011, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.