A Methodological Investigation of Three Psychophysical Techniques for Rapid Measurement of Contrast Sensitivity

A general method for assessing visual capacity, contrast sensitivity function (CSF), has emerged in the last decade. The CSF describes visual detection of sine-wave gratings over a range of visual sizes. The purpose of this investigation was to compare the stability and sensitivity of three methods of obtaining rapid CSFs: Method of Adjustment (ADJ), Bekesy Tracking (B), and Method of Increasing Contrast (MIC). For each method, a microcomputer controlled video display was used to generate five different stationary gratings: 1, 2, 4, 8, and 16 cycles per degree (cpd). Individual contrast sensitivity functions were determined for each of 13 observers over five days. Analyses were conducted on reliabilities, means, and variances across frequencies, methods, and days. The MIC demonstrated near-largest or largest reliabilities over all frequencies across days. The MIC, in addition, appeared differentially stable from the onset of measurement (p > .10); while, both ADJ and B methods demonstrated differential instability (p < .002). The Methodof Increasing Contrast (MIC) may be recommended as the method of choice for assessing CSF based on the present findings.

[1]  Ivan Bodis-Wollner,et al.  Visual Acuity and Contrast Sensitivity in Patients with Cerebral Lesions , 1972, Science.

[2]  A. Ginsburg,et al.  Contrast sensitivity predicts pilots' performance in aircraft simulators. , 1982, American journal of optometry and physiological optics.

[3]  D Regan,et al.  Contrast sensitivity, visual acuity and the discrimination of Snellen letters in multiple sclerosis. , 1981, Brain : a journal of neurology.

[4]  C. Hulin,et al.  Two Explanations of Temporal Changes in Ability-Skill Relationships: A Literature Review and Theoretical Analysis , 1972 .

[5]  J. M. Enoch,et al.  CLINICAL APPLICATIONS OF VISUAL PSYCHOPHYSICS , 1984 .

[6]  Robert S. Kennedy,et al.  Performance Evaluation Tests for Environmental Research (Peter): Bibliography , 1983 .

[7]  G B Arden,et al.  A simple grating test for contrast sensitivity: preliminary results indicate value in screening for glaucoma. , 1978, Investigative ophthalmology & visual science.

[8]  J SWETS,et al.  Decision processes in perception. , 1961, Psychological review.

[9]  William F. Moroney,et al.  The Accommodated Proportion of a Potential User Population: Compilation and Comparisons of Methods for Estimation , 1974 .

[10]  R. Hess,et al.  On the relationship between pattern and movement perception in strabismic amblyopia , 1978, Vision Research.

[11]  Alvah C. Bittner,et al.  Repeated measurements of manual dexterity Applications and support of the two-process theory , 1982 .