Feasibility Study of an Express Assessment Protocol for the Indoor Air Quality of Air-conditioned Offices

It is costly to sample all major toxic pollutants in community air. Sampling should be conducted based on an assessment strategy and monitoring planning. Assessment methods that rely on monitoring some representative pollutants have been proposed variously at different times. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade the IAQ in workplaces as “Excellent” or “Good” by measuring the levels of 12 indoor environmental parameters, i.e. carbon dioxide (CO2), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO2), ozone (O3), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), airborne bacteria count (ABC), temperature (T), relative humidity (RH) and air velocity (V). The present study proposes an Express Assessment Protocol (EAP) to quantify IAQ problems by assessing the “dominant” contributors to unacceptable IAQ prior to any detailed assessment for benchmark purposes. To aid this, a comprehensive measurement of the 12 stated indoor environmental parameters was performed in some Hong Kong offices. The results were used to identify the dominant contributors and assess the performance of the proposed protocol in identifying the associated IAQ problems in an office environment. Comparing the results with the parameter measurements in the certification scheme they showed that for the “Excellent” IAQ level, 96% (94 to 98% for 95% confidence interval (CI)) of the “unacceptable” offices (414 samples) could be identified from the measurements of TVOC, RSP and HCHO; while those that achieved the “Good” level, 93% (90 to 97% for 95% CI) of them (201 samples) could be identified from the measurements of TVOC, ABC, RH, HCHO and O3. The EAP would be a useful tool for policymakers, building owners and professionals to quantify IAQ problems in offices and to make improved decisions based on resources and manpower management for efficient mitigation actions.

[1]  M. V. Jokl,et al.  Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC , 2000 .

[2]  Hai Guo,et al.  Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong , 2002 .

[3]  John A. Hoskins,et al.  Health Effects due to Indoor Air Pollution , 2003 .

[4]  Derrick Crump,et al.  Development and Application of a Protocol for the Assessment of Indoor Air Quality , 2003 .

[5]  Elizabeth Agle,et al.  Building Air Quality: A Guide for Building Owners and Facility Managers. , 1991 .

[6]  K.W.D. Cheong,et al.  Development and application of an indoor air quality audit to an air-conditioned building in Singapore , 2001 .

[7]  Michael S. Crandall,et al.  The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. Part One: Building Environmental Evaluations , 1996 .

[8]  L. T. Wong,et al.  Survey on the air diffusion devices for air-conditioning systems in Hong Kong , 1998 .

[9]  J. Lodge Air quality guidelines for Europe: WHO regional publications, European series, No. 23, World Health Organization, 1211 Geneva 27, Switzerland; WHO publications center USA, 49 Sheridan Avenue, Albany, NY 12210, 1987, xiii + 426 pp. price: Sw. fr. 60 , 1988 .

[10]  Christopher Yu Hang Chao,et al.  Feasibility Study of an Indoor Air Quality Measurement Protocol on 12 Parameters in Mechanically Ventilated and Air-Conditioned Buildings , 2001 .

[11]  John Burnett,et al.  Indoor Air Quality Certification Scheme for Hong Kong Buildings , 2005 .

[12]  L. T. Wong,et al.  A New Sampling Approach for Assessing Indoor Air Quality , 2006 .

[13]  Martin Kraenzmer,et al.  Modeling and continuous monitoring of indoor air pollutants for identification of sources and sinks , 1999 .

[14]  J B Lucas,et al.  The National Institute for Occupational Safety and Health , 1977, Contact dermatitis.

[15]  Andrew P. Jones,et al.  Indoor air quality and health , 1999 .

[16]  L. T. Wong,et al.  Evaluation on sampling point densities for assessing indoor air quality , 2006 .

[17]  Wan Ki Chow,et al.  Experimental studies on air diffusion of a linear diffuser and associated thermal comfort indices in an air-conditioned space , 1994 .

[18]  L. T. Wong,et al.  Evaluation on different sampling schemes for assessing indoor radon level in Hong Kong , 2004 .

[19]  Kenneth M. Wallingford,et al.  The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. Part Three: Associations between Environmental Factors and Self-Reported Health Conditions , 1996 .

[20]  K.W.D. Cheong,et al.  Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics , 2003 .

[21]  K. Mui,et al.  Epistemic assessment of radon level of offices in Hong Kong , 2006 .

[22]  K. Martinez,et al.  350. Niosh Indoor Air Quality Investigation of a Hurricane Damaged Outpatient Clinic in the United States Virgin Islands , 2002 .