Design and Evaluation of Fiber-Reinforced Polymer Bond-Type Anchorages and Ground Anchors

This paper presents laboratory tests on a bond-type anchorage system and a full-scale ground anchor with fiber-reinforced polymer 9-bar tendons. A cement-based mortar filled steel tube was used to simulate a rock mass environment. Resistance strain gauges, fiber optic sensors, embedded strain gauges, and linear variable displacement transducers were used to monitor the behavior of the anchor and to study load transfer mechanism of the tendon to surrounding rock mass. The test results show that the developed bond-type anchorage performs well for post-tensing applications with the tendons. The tested anchor presents an acceptable tensile behavior for each loading stage investigated (up to a load level of 0.6 ffu , where ffu =guaranteed capacity of the tendon) in accordance with existing codes. The anchor is similar in strain distribution profile to conventional steel anchors, except giving a shorter load transfer length. It is expected that the anchor require a minimum anchor bonded length of 2,000 mm with ...

[1]  L. Malvar Tensile and Bond Properties of GFRP Reinforcing Bars , 1995 .

[2]  Brahim Benmokrane,et al.  Evaluation of aramid and carbon fibre reinforced polymer composite tendons for prestressed ground anchors , 2000 .

[3]  Petros P. Xanthakos,et al.  Ground anchors and anchored structures , 1991 .

[4]  Claude Bédard,et al.  Composite Reinforcing Bars: Assessing Their Use in Construction , 1992 .

[5]  Denis Mitchell,et al.  Analysis of Bond Stress Distributions in Pullout Specimens , 1996 .

[6]  Brahim Benmokrane,et al.  Five-year monitoring of load losses on prestressed cement-grouted rock anchors , 1991 .

[7]  G S Littlejohn,et al.  ROCK ANCHORS - STATE OF THE ART , 1977 .

[8]  Brahim Benmokrane,et al.  Tensile properties and pullout behaviour of AFRP and CFRP rods for grouted anchor applications , 2000 .

[9]  Brahim Benmokrane,et al.  PREDICTION OF TENSILE CAPACITY OF BOND ANCHORAGES FOR FRP TENDONS , 2000 .

[10]  Brahim Benmokrane,et al.  LABORATORY EVALUATION OF FIBER-OPTIC SENSORS FOR STRAIN MONITORING , 2003 .

[11]  Brahim Benmokrane,et al.  Pullout Bond Properties of Fiber-Reinforced Polymer Tendons to Grout , 2002 .

[12]  R K Dunnam,et al.  ANCHORAGE TESTS ON STRAIN-GAUGED RESIN BONDED BOLTS , 1976 .

[13]  Gs Littlejohn,et al.  GROUND ANCHORAGES: CORROSION PERFORMANCE , 1987 .

[14]  Brahim Benmokrane,et al.  ARAMID AND CARBON FIBRE-REINFORCED PLASTIC PRESTRESSED GROUND ANCHORS AND THEIR FIELD APPLICATIONS , 1997 .

[15]  M. Erki,et al.  FRP Reinforcement for Concrete Structures , 1993 .

[16]  Brahim Benmokrane,et al.  Fiber-Optic Sensors Monitor FRP-Reinforced Bridge , 2001 .

[17]  Brahim Benmokrane,et al.  MONITORING BEHAVIOR OF GROUTED ANCHORS USING VIBRATING-WIRE GAUGES , 1995 .