Non-linear modeling of oil-paper insulation for condition assessment using non-sinusoidal excitation

In high voltage engineering, dielectric response analysis is a widely used tool for insulation diagnostic. Voltages used for studying dielectric response in the laboratory are usually sinusoidal in nature. But the insulation system in operation on site is often stressed by voltages that may deviate significantly from a sinusoid. Thus the use of nonsinusoidal waveform in obtaining the dielectric response is a desirable study for advanced insulation diagnostic technique. Present work involves assessing the condition of electrical insulation using dielectric response analysis under the influence of nonsinusoidal voltage waveform. In dielectric response analysis, characteristics curve of phase response over a frequency band is used to predict the insulation condition, which involves expertise. In this respect parameterization of insulation condition can make the assessment technique much simpler. But the nonlinear behavior of insulation restricts such an attempt to be accurate enough for reliable assessment of minute degradation of insulation condition. Therefore, the present work proposes a non-linear system identification technique, in an attempt to parameterize insulation condition. In this work, a suitable excitation signal has been designed so that the observed response becomes representative of the behavior of the whole system dynamics over the frequency band of interest. Tests have been performed with insulations having different moisture contents. The obtained system parameters, through nonlinear Hammerstein model, were found to be consistent over several experiments, and also accurate enough to detect small variation of moisture content. The proposed method is based on the time domain measurement of input excitation voltage and corresponding response current through the insulation.

[1]  M. Farzaneh,et al.  Dielectric spectroscopy techniques as quality control tool: a feasibility study , 2009, IEEE Electrical Insulation Magazine.

[2]  B. Chatterjee,et al.  Estimation of paper moisture content based on dielectric dissipation factor of oil-paper insulation under non-sinusoidal excitations , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Alessandro Ferrero,et al.  High-accuracy Fourier analysis based on synchronous sampling techniques , 1992 .

[4]  S. M. Mahajan,et al.  Time domain spectroscopy measurements for the insulation diagnosis of a current transformer , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  P. Purkait,et al.  Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Er-Wei Bai,et al.  Iterative identification of Hammerstein systems , 2007, Autom..

[7]  Er-Wei Bai,et al.  Iterative identification of Hammerstein systems , 2007, Autom..

[8]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[9]  P. Purkait,et al.  An attempt to correlate time & frequency domain polarisation measurements for the insulation diagnosis of power transformer , 2004, IEEE Power Engineering Society General Meeting, 2004..

[10]  W. S. Zaengl,et al.  Dielectric Response Methods for Diagnostics of Power Transformers , 2003 .

[11]  Ruijin Liao,et al.  Quantitative analysis of ageing condition of oil-paper insulation by frequency domain spectroscopy , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  D. Maksimovic,et al.  System identification of power converters with digital control through cross-correlation methods , 2005, IEEE Transactions on Power Electronics.

[14]  Feng Ding,et al.  Identification methods for Hammerstein nonlinear systems , 2011, Digit. Signal Process..

[15]  M. Koch,et al.  A fast and reliable dielectric diagnostic method to determine moisture in power transformers , 2008, 2008 International Symposium on Electrical Insulating Materials (ISEIM 2008).

[16]  K. D. Srivastava,et al.  Review of condition assessment of power transformers in service , 2002 .

[17]  Tapan Kumar Saha,et al.  Review of modern diagnostic techniques for assessing insulation condition in aged transformers , 2003 .

[18]  A. Setayeshmehr,et al.  Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditions , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  F.P. Espino-Cortes,et al.  Study of stress grading systems working under fast rise time pulses , 2006, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation.

[20]  C. Koley,et al.  Frequency domain dielectric spectroscopy using Triangular waveform , 2012, 2012 Annual IEEE India Conference (INDICON).

[21]  Nicanor Quijano Control Systems Technology Lab Lecture Notes , 2005 .

[22]  Tord Bengtsson,et al.  High and Low Voltage Dielectric Response Measurements Utilizing Arbitrarily Shaped Waveforms , 2007 .

[23]  F Meghnefi,et al.  On the frequency domain dielectric response of oil-paper insulation at low temperatures , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  A.J. Thomas,et al.  Impact of temperature on the frequency domain dielectric spectroscopy for the diagnosis of power transformer insulation , 2006, 2006 IEEE Power Engineering Society General Meeting.

[25]  T. Bengtsson,et al.  Dielectric response measurements utilizing semi-square voltage waveforms , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[26]  B. Chatterjee,et al.  Effect of temperature on frequency dependent dielectric parameters of oil-paper insulation under non-sinusoidal excitation , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[27]  M. de Nigris,et al.  APPLICATION OF MODERN TECHNIQUES FOR THE CONDITION ASSESSMENT OF POWER TRANSFORMERS , 2004 .

[28]  Yusheng Liu,et al.  Nonlinear Identification of Laser Welding Process , 2007, IEEE Transactions on Control Systems Technology.

[29]  Lennart Ljung,et al.  System Identification: Theory for the User , 1987 .

[30]  M. K. Pradhan,et al.  Experimental investigation of insulation parameters affecting power transformer condition assessment using frequency domain spectroscopy , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  Ming Dong,et al.  Novel characteristic parameters for oil-paper insulation assessment from differential time-domain spectroscopy based on polarization and depolarization current measurement , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[32]  Pahlavanpour,et al.  Study of moisture equilibrium in oil-paper system with temperature variation , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[33]  W. S. Zaengl,et al.  Dielectric spectroscopy in time and frequency domain for HV power equipment. I. Theoretical considerations , 2003 .

[34]  Ming Dong,et al.  Investigation on dielectric response characteristics of thermally aged insulating pressboard in vacuum and oil-impregnated ambient , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.

[35]  B. Chatterjee,et al.  Comparative study on the effect of temperature on frequency domain spectroscopy results under sinusoidal and triangular excitation , 2012, 2012 1st International Conference on Power and Energy in NERIST (ICPEN).