Higher adaptive optics loop rate enhances axial resolution in nonconfocal ophthalmoscopes.

In this Letter, we propose a way to better understand the impact of dynamic ocular aberrations in the axial resolution of nonconfocal adaptive optics (AO) ophthalmoscopes via a simulation of the 3D PSF in the retina for various AO-loop rates. We then use optical incoherence tomography, a method enabling the generation of tomographic retinal cross sections in incoherent imaging systems, to evaluate the benefits of a fast AO-loop rate on axial resolution and, consequently, on AO-corrected retinal image quality. We used the PARIS AO flood-illumination ophthalmoscope for this study, where retinal images from different focal planes at an AO-loop rate of 10 and 50 Hz were acquired.

[1]  Austin Roorda,et al.  Adaptive optics retinal imaging: emerging clinical applications. , 2010, Optometry and vision science : official publication of the American Academy of Optometry.

[2]  Jennifer J. Hunter,et al.  Imaging individual neurons in the retinal ganglion cell layer of the living eye , 2017, Proceedings of the National Academy of Sciences.

[3]  J. Ambati,et al.  Mechanisms of Age-Related Macular Degeneration , 2012, Neuron.

[4]  Jerome Mertz,et al.  Wide-field fluorescence sectioning with hybrid speckle and uniform-illumination microscopy. , 2008, Optics letters.

[5]  Serge Meimon,et al.  High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget. , 2017, Biomedical optics express.

[6]  T. Hebert,et al.  Adaptive optics scanning laser ophthalmoscopy. , 2002, Optics express.

[7]  A. Dubra,et al.  In vivo dark-field imaging of the retinal pigment epithelium cell mosaic. , 2013, Biomedical optics express.

[8]  Andrew B Metha,et al.  Reactivity in the human retinal microvasculature measured during acute gas breathing provocations , 2017, Scientific Reports.

[9]  W B Amos,et al.  Re‐evaluation of differential phase contrast (DPC) in a scanning laser microscope using a split detector as an alternative to differential interference contrast (DIC) optics , 2003, Journal of microscopy.

[10]  Krishnakumar Venkateswaran,et al.  Optical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope. , 2005, Applied optics.

[11]  Laurent M. Mugnier,et al.  Sub-pixel image registration with a maximum likelihood estimator. Application to the first adaptive optics observations of Arp 220 in the L' band , 2005 .

[12]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[13]  Austin Roorda,et al.  Disruption of the retinal parafoveal capillary network in type 2 diabetes before the onset of diabetic retinopathy. , 2011, Investigative ophthalmology & visual science.

[14]  R. D. Ferguson,et al.  In vivo near-infrared autofluorescence imaging of retinal pigment epithelial cells with 757 nm excitation. , 2018, Biomedical optics express.

[15]  Toco Y P Chui,et al.  The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope , 2012, Biomedical optics express.

[16]  Alexander Meadway,et al.  High-speed adaptive optics for imaging of the living human eye. , 2015, Optics express.

[17]  D R Williams,et al.  Supernormal vision and high-resolution retinal imaging through adaptive optics. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  Serge Meimon,et al.  Fixational eye movement: a negligible source of dynamic aberration. , 2018, Biomedical optics express.

[19]  F. Rossant,et al.  Adaptive optics ophthalmoscopy: Application to age-related macular degeneration and vascular diseases , 2018, Progress in Retinal and Eye Research.

[20]  Serge Meimon,et al.  High loop rate adaptive optics flood illumination ophthalmoscope with structured illumination capability. , 2018, Applied optics.