Coordinated Frequency and State-of-Charge Control with Multi-Battery Energy Storage Systems and Diesel Generators in an Isolated Microgrid

Recently, isolated microgrids have been operated using renewable energy sources (RESs), diesel generators, and battery energy storage systems (BESSs) for an economical and reliable power supply to loads. The concept of the complementary control, in which power imbalances are managed by diesel generators in the long time scale and BESSs in the short time scale, is widely adopted in isolated microgrids for efficient and stable operation. This paper proposes a new complementary control strategy for regulating the frequency and state of charge (SOC) when the system has multiple diesel generators and BESSs. In contrast to conventional complementary control, the proposed control strategy enables the parallel operation of diesel generators and BESSs, as well as SOC management. Furthermore, diesel generators regulate the equivalent SOC of BESSs with hierarchical control. Additionally, BESSs regulate the frequency of the system with hierarchical control and manage their individual SOCs. We conducted a case study by using Simulink/MATLAB to verify the effectiveness of the proposed control strategy in comparison with conventional complementary control.

[1]  A. Iturregi,et al.  Review of grid connection requirements for generation assets in weak power grids , 2015 .

[2]  Quanyuan Jiang,et al.  Wavelet-Based Capacity Configuration and Coordinated Control of Hybrid Energy Storage System for Smoothing Out Wind Power Fluctuations , 2013, IEEE Transactions on Power Systems.

[3]  Eung-Sang Kim,et al.  Frequency and Voltage Control Strategy of Standalone Microgrids With High Penetration of Intermittent Renewable Generation Systems , 2016, IEEE Transactions on Power Systems.

[4]  Arindam Ghosh,et al.  Frequency Support for Remote Microgrid Systems With Intermittent Distributed Energy Resources—A Two-Level Hierarchical Strategy , 2018, IEEE Systems Journal.

[5]  Xavier Guillaud,et al.  Real-time simulation: The missing link in the design process of advanced grid equipment , 2010, IEEE PES General Meeting.

[6]  Seung-Il Moon,et al.  Decentralised Active Power Control Strategy for Real-Time Power Balance in an Isolated Microgrid with an Energy Storage System and Diesel Generators , 2019, Energies.

[7]  Gilles Malarange,et al.  Dynamic frequency control support: A virtual inertia provided by distributed energy storage to isolated power systems , 2010, 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe).

[8]  Yi Liu,et al.  A Method for Sizing Energy Storage System to Increase Wind Penetration as Limited by Grid Frequency Deviations , 2016, IEEE Transactions on Power Systems.

[9]  M. Vitelli,et al.  Optimization of perturb and observe maximum power point tracking method , 2005, IEEE Transactions on Power Electronics.

[10]  Eung-Sang Kim,et al.  Distributed Generation Control Method for Active Power Sharing and Self-Frequency Recovery in an Islanded Microgrid , 2017, IEEE Transactions on Power Systems.

[11]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[12]  Jun Xiao,et al.  Sizing of Energy Storage and Diesel Generators in an Isolated Microgrid Using Discrete Fourier Transform (DFT) , 2014, IEEE Transactions on Sustainable Energy.

[13]  S. Magand,et al.  Evaluation of EVs energy consumption influencing factors, driving conditions, auxiliaries use, driver's aggressiveness , 2013, 2013 World Electric Vehicle Symposium and Exhibition (EVS27).

[14]  B. Singh,et al.  Load Compensation for Diesel Generator Based Isolated Generation System Employing DSTATCOM , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[15]  Matthew J. Reno,et al.  Sharing Transient Loads : Causes of Unequal Transient Load Sharing in Islanded Microgrid Operation , 2014, IEEE Industry Applications Magazine.

[16]  Mostafa F. Shaaban,et al.  An Efficient Planning Algorithm for Hybrid Remote Microgrids , 2019, IEEE Transactions on Sustainable Energy.

[17]  Ching-Tsai Pan,et al.  Modeling and Coordinate Control of Circulating Currents in Parallel Three-Phase Boost Rectifiers , 2007, IEEE Transactions on Industrial Electronics.

[18]  Xiaorong Xie,et al.  WAMS applications in Chinese power systems , 2006 .

[19]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[20]  Chul-Sang Hwang,et al.  State of Charge-Based Active Power Sharing Method in a Standalone Microgrid with High Penetration Level of Renewable Energy Sources , 2016 .

[21]  P. Kundur,et al.  Power system stability and control , 1994 .

[22]  C. Moo,et al.  Enhanced coulomb counting method for estimating state-of-charge and state-of-health of lithium-ion batteries , 2009 .

[23]  B. Francois,et al.  Dynamic Frequency Control Support by Energy Storage to Reduce the Impact of Wind and Solar Generation on Isolated Power System's Inertia , 2012, IEEE Transactions on Sustainable Energy.

[24]  Roger A. Dougal,et al.  Dynamic lithium-ion battery model for system simulation , 2002 .

[25]  Seyed Hossein Hosseinian,et al.  Decentralized Reactive Power Sharing and Frequency Restoration in Islanded Microgrid , 2017, IEEE Transactions on Power Systems.

[26]  Miguel Castilla,et al.  Control of Power Converters in AC Microgrids , 2018, Microgrids Design and Implementation.

[27]  Juan C. Vasquez,et al.  Centralized Control Architecture for Coordination of Distributed Renewable Generation and Energy Storage in Islanded AC Microgrids , 2017, IEEE Transactions on Power Electronics.