Contrast-enhanced functional blood volume imaging (CE-fBVI): Enhanced sensitivity for brain activation in humans using the ultrasmall superparamagnetic iron oxide agent ferumoxytol

Functional MRI (fMRI) brain studies performed in the presence of a steady-state or "blood pool" contrast agent yields activation maps that are weighted for cerebral blood volume (CBV). Previous animal experiments suggest significant contrast-to-noise ratio (CNR) improvements, but these studies have not yet been performed in humans due to the lack of availability of a suitable agent. Here we report the use of the USPIO ferumoxytol (AMAG Pharmaceuticals, Inc., Cambridge, MA) for functional brain activation in humans, termed contrast enhanced functional blood volume imaging (CE-fBVI). Four subjects were scanned during a unilateral finger tapping task with standard blood-oxygen level dependent (BOLD) imaging before contrast and CE-fBVI after contrast injection. The CE-fBVI response showed both a fast (5.8±1.3 s) and a slow (75.3±27.5 s) component of CBV response to stimuli. A significant CNR gain of approximately 2-3 was found for CE-fBVI compared to BOLD fMRI. Interestingly, less susceptibility-related signal dropouts were observed in the inferior frontal and temporal lobes with CE-fBVI. The combination of higher CNR and better spatial specificity, enabled by CE-fBVI using blood pool USPIO contrast agent opens the door to higher resolution brain mapping.

[1]  Essa Yacoub,et al.  High-field fMRI unveils orientation columns in humans , 2008, Proceedings of the National Academy of Sciences.

[2]  Ping Wang,et al.  Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: Insights into hemodynamic regulation , 2006, NeuroImage.

[3]  B R Rosen,et al.  Mr contrast due to intravascular magnetic susceptibility perturbations , 1995, Magnetic resonance in medicine.

[4]  Peter T Fox,et al.  Evaluation of MRI models in the measurement of CMRO2 and its relationship with CBF , 2008, Magnetic resonance in medicine.

[5]  B. Rosen,et al.  Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation , 1998, Magnetic resonance in medicine.

[6]  Hanbing Lu,et al.  Quantifying the blood oxygenation level dependent effect in cerebral blood volume–weighted functional MRI at 9.4T , 2007, Magnetic resonance in medicine.

[7]  J. Pekar,et al.  Functional magnetic resonance imaging based on changes in vascular space occupancy , 2003, Magnetic resonance in medicine.

[8]  Anders M. Dale,et al.  Repeated fMRI Using Iron Oxide Contrast Agent in Awake, Behaving Macaques at 3 Tesla , 2002, NeuroImage.

[9]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[10]  Steen Moeller,et al.  Combined imaging–histological study of cortical laminar specificity of fMRI signals , 2006, NeuroImage.

[11]  A. Grinvald,et al.  Interactions Between Electrical Activity and Cortical Microcirculation Revealed by Imaging Spectroscopy: Implications for Functional Brain Mapping , 1996, Science.

[12]  R. Buxton,et al.  Dynamics of blood flow and oxygenation changes during brain activation: The balloon model , 1998, Magnetic resonance in medicine.

[13]  B. Rosen,et al.  Functional mapping of the human visual cortex by magnetic resonance imaging. , 1991, Science.

[14]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[15]  William D Rooney,et al.  Superparamagnetic Iron Oxide Nanoparticles: Diagnostic Magnetic Resonance Imaging and Potential Therapeutic Applications in Neurooncology and Central Nervous System Inflammatory Pathologies, a Review , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[16]  B. Rosen,et al.  Microscopic susceptibility variation and transverse relaxation: Theory and experiment , 1994, Magnetic resonance in medicine.

[17]  Ravi S. Menon,et al.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. , 1993, Biophysical journal.

[18]  Lawrence L. Wald,et al.  Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters , 2005, NeuroImage.

[19]  Thoralf M. Sundt,et al.  The effect of carbon dioxide on the diameter of brain capillaries , 1990, Brain Research.

[20]  J. Hyde,et al.  Spatial correlations of laminar BOLD and CBV responses to rat whisker stimulation with neuronal activity localized by Fos expression , 2004, Magnetic resonance in medicine.

[21]  Ji-Kyung Choi,et al.  Exogenous contrast agent improves sensitivity of gradient‐echo functional magnetic resonance imaging at 9.4 T , 2004, Magnetic resonance in medicine.

[22]  R. Duelli,et al.  Changes in Brain Capillary Diameter during Hypocapnia and Hypercapnia , 1993, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.