Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants.

The purpose of the present study was to compare wear particles isolated from metal-metal (MM) hip implants worn in an orbital bearing simulator with particles from similar MM total hip replacement (THR) implants worn in vivo. Comparison of these particles is important because it will help to assess the overall suitability of this type of hip simulator for reproducing in vivo wear and for producing physiological wear particles suitable for biological studies of in vitro cellular response. Commercial grade components made of ASTM F75 (cast) alloy were evaluated. Simulator tests were performed in 95% bovine calf serum with a 28-mm-diameter implant. Wear particles were collected from 0 to 0.25 million cycles (run-in wear period) and 1.75 to 2 million cycles (steady-state wear period). Tissues from seven patients with MM implants (surface replacement or stem type) were harvested at revision surgeries (after 1-43 months). Metal wear particles were isolated from serum lubricant or tissues using an enzymatic protocol that was previously optimized to minimize particle changes due to reagents. After isolation, particles were centrifuged, embedded in epoxy resin, and characterized by transmission electron microscopy (TEM) and energy dispersive X-ray analysis (EDXA). Results of EDXA on particles from the hip simulator primarily indicated a predominance of particles containing Cr and O but no Co (most likely chromium oxide particles), and fewer CoCrMo particles presenting varying ratios of Co and Cr. Image analysis of TEM micrographs demonstrated that the majority of the particles from the simulator were round to oval, but a substantial number of needle-shaped particles were also found, especially from 0 to 0.25 Mc. The particles generated from 0 to 0.25 Mc had an average length of 53 nm, whereas those generated from 1.75 to 2 Mc had an average length of 43 nm. In vivo, EDXA and TEM analysis of particles that were retrieved from two patients at 23 and 43 months respectively, revealed that they were the most comparable in composition, average length (57 nm), and shape to particles generated in the hip simulator during the run-in wear period. Because a large clinical retrieval study in the literature suggested that a run-in wear regime might occur in vivo for some 6-36 months, the fidelity of the simulator of the present study was strongly supported. However, some uncertainties existed, including the finding that the particles isolated from the other five patients generated from 1 month up to 15 months (shorter implantation times than the other two patients) were smaller and mostly contained only Cr and O (no Co). In the opinion of the authors, this particular very short term patient group was somewhat atypical. Therefore, despite these uncertainties, the present study was deemed to support the ability of the orbital bearing hip simulator to produce physiological wear particles.

[1]  C. Rieker,et al.  Analysis of 118 second-generation metal-on-metal retrieved hip implants. , 1999, The Journal of bone and joint surgery. British volume.

[2]  D. Zukor,et al.  Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. , 1998, Journal of biomedical materials research.

[3]  A. Wang,et al.  Residual Abrasive Material from Surface Grinding of Metal-Metal Hip Implants: A Source of Third-Body Wear? , 1999 .

[4]  J. Black,et al.  Size and shape of biomaterial wear debris. , 1994, Clinical materials.

[5]  I. Clarke,et al.  Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. , 1999, Acta orthopaedica Scandinavica.

[6]  A. Taylor,et al.  Systemic distribution of wear debris after hip replacement. A cause for concern? , 1992, Journal of Bone and Joint Surgery-british Volume.

[7]  J O Galante,et al.  Composition and morphology of wear debris in failed uncemented total hip replacement. , 1994, The Journal of bone and joint surgery. British volume.

[8]  J. Fisher,et al.  Influence of simulator kinematics on the wear of metal-on-metal hip prostheses , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  D. Zukor,et al.  Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape. , 2001, Journal of biomedical materials research.

[10]  A. Wang,et al.  Surface characterization of metal-on-metal hip implants tested in a hip simulator , 1999 .

[11]  P. Campbell,et al.  Tissue Reaction to Metal on Metal Total Hip Prostheses , 1996, Clinical orthopaedics and related research.

[12]  T P Schmalzried,et al.  Quantitative Assessment of Walking Activity after Total Hip or Knee Replacement* , 1998, The Journal of bone and joint surgery. American volume.

[13]  R. Schenk,et al.  Wear Behavior and Histopathology of Classic Cemented Metal on Metal Hip Endoprostheses , 1996, Clinical orthopaedics and related research.

[14]  O. Wahlström,et al.  20-Year Results of McKee-Farrar Versus Charnley Prosthesis , 1996 .

[15]  W. Harris,et al.  Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. , 1996, The Journal of arthroplasty.

[16]  F. Chan,et al.  Comparison of Alloys and Designs in a Hip Simulator Study of Metal on Metal Implants , 1996, Clinical orthopaedics and related research.

[17]  T. Bauer,et al.  Isolation and characterization of debris in membranes around total joint prostheses. , 1994, The Journal of bone and joint surgery. American volume.

[18]  D. Dowson,et al.  The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  P. Campbell,et al.  Tissue digestion for wear debris particle isolation. , 1994, Journal of biomedical materials research.

[20]  J. Galante,et al.  Macrophage/particle interactions: effect of size, composition and surface area. , 1994, Journal of biomedical materials research.

[21]  T. Bauer,et al.  Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty. A cause of late failure. , 1992, The Journal of arthroplasty.

[22]  W. Maloney,et al.  Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. , 1995, The Journal of bone and joint surgery. American volume.

[23]  M. Wimmer,et al.  Tribochemical reaction on metal-on-metal hip joint bearings A comparison between in-vitro and in-vivo results , 2003 .

[24]  F. Shen,et al.  Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. , 1999, Clinical orthopaedics and related research.

[25]  D. Zukor,et al.  Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. II. Analysis of ion release and particle composition. , 2001, Journal of biomedical materials research.

[26]  H. Mckellop,et al.  Potential thermal artifacts in hip joint wear simulators. , 1999, Journal of biomedical materials research.

[27]  Michael Tanzer,et al.  Engineering issues and wear performance of metal on metal hip implants. , 1996, Clinical orthopaedics and related research.

[28]  C. Rimnac,et al.  Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. , 1994, The Journal of bone and joint surgery. British volume.

[29]  R. Streicher,et al.  [The wear behavior of capsules and heads of CoCrMo casts in long-term implanted all-metal hip prostheses]. , 1989, Der Orthopade.

[30]  Jack R. Worrall,et al.  Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. , 1998, Journal of biomedical materials research.

[31]  J Fisher,et al.  Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. , 1998, Biomaterials.

[32]  Michael Tanzer,et al.  The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. , 1999, Clinical orthopaedics and related research.

[33]  D. Zukor,et al.  Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. , 2003, Journal of biomedical materials research. Part A.

[34]  B. Corrin,et al.  In vivo corrosion of cobalt-chromium and titanium wear particles. , 1995, The Journal of bone and joint surgery. British volume.

[35]  D Dowson,et al.  A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.