A 3-D SAR model for current source interstitial hyperthermia

A three-dimensional (3-D) model is presented for the calculation of the specific absorption rate (SAR) in human tissue during current source interstitial hyperthermia. The model is capable of millimeter resolution and can cope with irregular implants in heterogeneous tissue. The SAR distribution is calculated from the electrical potential. The potential distribution is determined by the dielectric properties of the tissue and by the electrode configuration. The dielectric properties and the current injection of the electrodes are represented on a 3-D uniform grid. The calculated potential at an electrode current injection point is not the actual electrode potential at that point. To estimate this potential a grid independent representation of an electrode together with an analytical solution in the neighborhood of the electrode are used. The calculated potential on the electrode surface is used to estimate the electrode impedance. The tissue implementation is validated by comparing calculated distributions with analytical solutions. The electrode implementation is verified by comparing different discretizations of an electrode configuration and by comparing numerically calculated electrode impedances with analytically calculated impedances.

[1]  J.J.W. Lagendijk,et al.  A fast and simple algorithm for the calculation of convective heat transfer by large vessels in three-dimensional inhomogeneous tissues , 1991, IEEE Transactions on Biomedical Engineering.

[2]  R B Roemer,et al.  Applications of bioheat transfer simulations in hyperthermia. , 1984, Cancer research.

[3]  P. Levendag,et al.  An interstitial hyperthermia system at 27 MHz. , 1989, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  J Crezee,et al.  Temperature uniformity during hyperthermia: the impact of large vessels. , 1992, Physics in medicine and biology.

[5]  A. Guy,et al.  Nonionizing electromagnetic wave effects in biological materials and systems , 1972 .

[6]  S. Frankel,et al.  Stability conditions in the numerical treatment of parabolic differential equations , 1953 .

[7]  J Lagendijk,et al.  A description of discrete vessel segments in thermal modelling of tissues. , 1996, Physics in medicine and biology.

[8]  D. Sullivan,et al.  Direct use of CT scans for hyperthermia treatment planning , 1992, IEEE Transactions on Biomedical Engineering.

[9]  J. Doss,et al.  A technique for localized heating in tissue: an adjunct to tumor therapy. , 1976, Medical instrumentation.

[10]  M. Nadi,et al.  Practical interstitial method of heating operating at 27.12 MHz. , 1989, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  M A Moerland,et al.  Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D. , 1994, Magnetic resonance imaging.

[12]  J. Lagendijk,et al.  Dose uniformity in scanned focused ultrasound hyperthermia. , 1994, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[13]  P. Levendag,et al.  Application of a capacitive-coupling interstitial hyperthermia system at 27 MHz: study of different applicator configurations. , 1991, Physics in medicine and biology.

[14]  P. M. van den Berg,et al.  A three-dimensional iterative scheme for an electromagnetic capacitive applicator , 1990, IEEE Transactions on Biomedical Engineering.