FINITE ELEMENT ANALYSIS OF THE HUMANA DENTAL IMPLANTS WITH AN INNOVATIVE SURFACE AND THREAD DESIGN TO REVEAL THE STRESS DISTRIBUTION IN THE IMPLANT, BONE TISSUE AND AT THE ABUTMENT-IMPLANT-BONE INTERFACE

This article presents the results of mathematical modeling of the stress-strain state of the finite element analysis of the justification for the use of Humana Dental implants with an innovative surface microstructure and thread design parameters during dental implantation. As a result of the study, after placing the implants in the created three-dimensional model, consisting of trabecular and cortical bones, it was revealed that the angle of implant placement significantly affects the distribution of stress in the bone. The rough, well-structured surface improves the contact of the implant with the bone. The stress distribution on dental implants with different geometry and thread design was revealed, and the most effective thread parameters for uniform load distribution were determined. Aim. Substantiation of the use of Humana Dental implants with innovative macro-microstructure of the surface and thread design parameters during dental implantation in various clinical situations. Material and methods. Samples of BioSink and Vega implants from Humana Dental were studied to assess the stress distribution by mathematical modeling of the stress-strain state in the cortical and spongy bone surrounding two models of implants with a diameter of 4.2 mm and a length of 11.5 mm, as well as with a different thread shape design. The implants were installed in the created three-dimensional model strictly vertically and at an angle of 30°. Geometric models were built in CAD Catia V5, the calculation was carried out in the software package Ansys R19.2. Resalts. As a result of the study, it was revealed that in all cases the maximum concentration of stresses falls on the cortical layer of bone near contact with the implant, and in the spongy bone with vertical installation, maximum stresses in all cases are reached near the lower part of the implant. The peak voltage in the cortical bone was highest in the threaded part of the implants. When changing the angle of installation of the implant, the maximum voltages can increase many times, but when changing the thread pitch, only small fluctuations in voltages are noted, which do not fit into any trend. In the peri-implant region, the cortical bone showed a higher concentration of tension than the spongy bone. Conclusions. The use of finite element analysis made it possible to identify the stress distribution on dental implants with different thread geometries and designs and to determine the most effective thread parameters for uniform load distribution.

[1]  Gabriele Cervino,et al.  Finite Element Method and Von Mises Investigation on Bone Response to Dynamic Stress with a Novel Conical Dental Implant Connection , 2020, BioMed research international.

[2]  M. Redaelli,et al.  Finite Element Analysis of a New Dental Implant Design Optimized for the Desirable Stress Distribution in the Surrounding Bone Region , 2020, Prosthesis.

[3]  Kuo-Chih Su,et al.  Biomechanical Design Application on the Effect of Different Occlusion Conditions on Dental Implants with Different Positions—A Finite Element Analysis , 2020, Applied Sciences.

[4]  Claudio Stacchi,et al.  Primary Stability Optimization by Using Fixtures with Different Thread Depth According To Bone Density: A Clinical Prospective Study on Early Loaded Implants , 2019, Materials.

[5]  M. Al-Sabbagh,et al.  Can Osseointegration Be Achieved Without Primary Stability? , 2019, Dental clinics of North America.

[6]  G. Spagnuolo,et al.  Micro-Scale Surface Patterning of Titanium Dental Implants by Anodization in the Presence of Modifying Salts , 2019, Materials.

[7]  T. Albrektsson,et al.  On osseointegration in relation to implant surfaces. , 2019, Clinical implant dentistry and related research.

[8]  Matthew J Dalby,et al.  Impact of surface topography and coating on osteogenesis and bacterial attachment on titanium implants , 2018, Journal of tissue engineering.

[9]  Daniel Rittel,et al.  Modeling the effect of osseointegration on dental implant pullout and torque removal tests. , 2018, Clinical implant dentistry and related research.

[10]  Furqan A. Shah,et al.  A Review of the Impact of Implant Biomaterials on Osteocytes , 2018, Journal of dental research.

[11]  J. Strnad,et al.  Chronological Age as Factor Influencing the Dental Implant Osseointegration in the Jaw Bone. , 2018, Prague medical report.

[12]  Назим Адиль Оглу Панахов,et al.  THE STABILITY LEVEL OF DENTAL IMPLANTS IN DIFFERENT PERIODS OF FUNCTIONING , 2018 .

[13]  N. Astashina,et al.  FORECASTING OUTCOMES OF DENTAL IMPLANTATION ON THE BASIS OF STUDYING THE LEVEL OF PRODUCTS OF OXIDATIVE MODIFICATION OF SALIVA PROTEINS , 2017 .

[14]  Mansi Manish Oswal,et al.  Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis , 2016, Journal of Indian Prosthodontic Society.

[15]  N. Sheibani,et al.  The role of angiogenesis in implant dentistry part I: Review of titanium alloys, surface characteristics and treatments , 2016, Medicina oral, patologia oral y cirugia bucal.

[16]  Peng Zhang,et al.  A Three-Dimensional Finite Element Study on the Biomechanical Simulation of Various Structured Dental Implants and Their Surrounding Bone Tissues , 2016, International journal of dentistry.

[17]  Tolga Topkaya,et al.  Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants , 2016 .

[18]  S. Gehrke Importance of Crown Height Ratios in Dental Implants on the Fracture Strength of Different Connection Designs: An In Vitro Study. , 2015, Clinical implant dentistry and related research.

[19]  A. Barfeie,et al.  Implant surface characteristics and their effect on osseointegration , 2015, BDJ.

[20]  Jong-Ho Lee,et al.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review , 2014, The journal of advanced prosthodontics.

[21]  G. Romanos,et al.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. , 2013, Interventional medicine & applied science.

[22]  Shu-Wei Wu,et al.  The effects of flute shape and thread profile on the insertion torque and primary stability of dental implants. , 2012, Medical engineering & physics.

[23]  D. A. Garzón-Alvarado,et al.  A finite element method approach for the mechanobiological modeling of the osseointegration of a dental implant , 2011, Comput. Methods Programs Biomed..

[24]  Sinan Müftü,et al.  Load transfer along the bone-dental implant interface. , 2010, Journal of biomechanics.

[25]  Hom-Lay Wang,et al.  The effect of thread pattern upon implant osseointegration. , 2010, Clinical oral implants research.

[26]  Jui-Ting Hsu,et al.  Bone stress and interfacial sliding analysis of implant designs on an immediately loaded maxillary implant: a non-linear finite element study. , 2008, Journal of dentistry.

[27]  F Rupp,et al.  Surface characteristics of dental implants: A review. , 2018, Dental materials : official publication of the Academy of Dental Materials.