Electrocardiogram Derived Respiratory Rate Using a Wearable Armband

A method for deriving respiratory rate from an armband, which records three-channel electrocardiogram (ECG) using three pairs of dry (no hydrogel) electrodes, is presented. The armband device is especially convenient for long-term (months-years) monitoring because it does not use obstructive leads nor hydrogels/adhesives, which cause skin irritation even after few days. An ECG-derived respiration (EDR) based on respiration-related modulation of QRS slopes and R-wave angle approach was used. Moreover, we modified the EDR algorithm to lower the computational cost. Respiratory rates were estimated with the armband-ECG and the reference plethysmography-based respiration signals from 15 subjects who underwent breathing experiment consisting of five stages of controlled breathing (at 0.1, 0.2, 0.3, 0.4, and 0.5 Hz) and one stage of spontaneous breathing. The respiratory rates from the armband obtained a relative error with respect to the reference (respiratory rate estimated from the plethysmography-based respiration signal) that was not higher than 2.26% in median nor interquartile range (IQR) for all stages of fixed and spontaneous breathing, and not higher than 3.57% in median nor IQR in the case when the low computational cost algorithm was applied. These results demonstrate that respiration-related modulation of the ECG morphology are also present in the armband ECG device. Furthermore, these results suggest that respiration-related modulation can be exploited by the EDR method based on QRS slopes and R-wave angles to obtain respiratory rate, which may have a wide range of applications including monitoring patients with chronic respiratory diseases, epileptic seizures detection, stress assessment, and sleep studies, among others.

[1]  Urs Frey,et al.  Complexity of chronic asthma and chronic obstructive pulmonary disease: implications for risk assessment, and disease progression and control , 2008, The Lancet.

[2]  B. Krieger,et al.  Continuous noninvasive monitoring of respiratory rate in critically ill patients. , 1986, Chest.

[3]  W. Shimizu,et al.  Validation of wearable textile electrodes for ECG monitoring , 2019, Heart and Vessels.

[4]  J. Hirsch,et al.  Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate. , 1981, The American journal of physiology.

[5]  Pablo Laguna,et al.  A robust method for ECG-based estimation of the respiratory frequency during stress testing , 2006, IEEE Transactions on Biomedical Engineering.

[6]  L. Tarassenko,et al.  An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram , 2016, Physiological measurement.

[7]  Jesús Lázaro,et al.  Nocturnal Heart Rate Variability Spectrum Characterization in Preschool Children With Asthmatic Symptoms , 2018, IEEE Journal of Biomedical and Health Informatics.

[8]  Louis Passfield,et al.  Respiratory Frequency during Exercise: The Neglected Physiological Measure , 2017, Front. Physiol..

[9]  Ki H. Chon,et al.  Novel Electrodes for Underwater ECG Monitoring , 2014, IEEE Transactions on Biomedical Engineering.

[10]  R. Parkes,et al.  Rate of respiration: the forgotten vital sign. , 2011, Emergency nurse : the journal of the RCN Accident and Emergency Nursing Association.

[11]  Jesús Lázaro,et al.  Inclusion of Respiratory Frequency Information in Heart Rate Variability Analysis for Stress Assessment , 2016, IEEE Journal of Biomedical and Health Informatics.

[12]  John F. Morales,et al.  A Comparative Study of ECG-derived Respiration in Ambulatory Monitoring using the Single-lead ECG , 2020, Scientific Reports.

[13]  J. G. Weg,et al.  Respiratory rate as an indicator of acute respiratory dysfunction. , 1980, JAMA.

[14]  Sang-Hoon Lee,et al.  CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring , 2012, IEEE Transactions on Biomedical Engineering.

[15]  M. Piepoli,et al.  Quantitative General Theory for Periodic Breathing in Chronic Heart Failure and its Clinical Implications , 2000, Circulation.

[16]  Jesús Lázaro,et al.  Pilot Study on Electrocardiogram Derived Respiratory Rate Using a Wearable Armband , 2018, 2018 Computing in Cardiology Conference (CinC).

[17]  P. Laguna,et al.  Electrocardiogram Derived Respiratory Rate from QRS Slopes and R-Wave Angle , 2014, Annals of Biomedical Engineering.

[18]  Sabine Van Huffel,et al.  Can ECG monitoring identify seizures? , 2015, Journal of electrocardiology.

[19]  Jesús Lázaro,et al.  Wearable Armband Device for Daily Life Electrocardiogram Monitoring , 2020, IEEE Transactions on Biomedical Engineering.

[20]  Raimon Jané,et al.  Time-varying signal analysis to detect high-altitude periodic breathing in climbers ascending to extreme altitude , 2015, Medical & Biological Engineering & Computing.

[21]  Ki H. Chon,et al.  Respiratory Rate Estimation from the Built-in Cameras of Smartphones and Tablets , 2013, Annals of Biomedical Engineering.

[22]  Sabine Van Huffel,et al.  A Novel Algorithm for the Automatic Detection of Sleep Apnea From Single-Lead ECG , 2015, IEEE Transactions on Biomedical Engineering.

[23]  F. Martinez,et al.  Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summary. , 2007, American journal of respiratory and critical care medicine.

[24]  U. Koehler,et al.  [Respiratory Rate - a Neglected Vital Sign]. , 2017, Deutsche medizinische Wochenschrift.

[25]  Spyridon Kontaxis,et al.  ECG-Derived Respiratory Rate in Atrial Fibrillation , 2020, IEEE Transactions on Biomedical Engineering.

[26]  Ki H. Chon,et al.  VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm , 2019, IEEE Access.