Magnetic filter field dependence of the performance of the RF driven IPP prototype source for negative hydrogen ions

The ITER neutral beam system requires a negative hydrogen ion beam of 48 A with an energy of 0.87 MeV and a negative deuterium beam of 40 A with an energy of 1 MeV. The beam is extracted from a large RF driven ion source with the dimension of 1.9 × 0.9 m2. An important role for the transport of the negative hydrogen ions to the extractor and the suppression of the co-extracted electrons is the magnetic filter field in front of the extractor. For the large ITER source the filter field will be generated by a current of up to 4 kA flowing through the first grid of the extractor. The extrapolation of the results obtained with the small IPP RF prototype source, where the filter field has a different 3D structure as it is generated by permanent magnets, is not straightforward. Furthermore, the filter field is by far not optimized due to the technical constraints of the RF source. Therefore, a frame that surrounds the ion sources and hosts permanent magnets was constructed for a fast and flexible change of the filter field. First results in hydrogen show that a minimum field of 3 mT in front of the extractor is needed for a sufficiently large number of extracted negative hydrogen ions, whereas sufficient co-extracted electron suppression is achieved by a source integrated magnetic field of more than 1.0 mTm.

[1]  T. Imai,et al.  Experimental study on spatial uniformity of H- ion beam in a large negative ion source , 2005 .

[2]  R. S. Hemsworth,et al.  Status of the ITER heating neutral beam system , 2009 .

[3]  T. Inoue,et al.  Uniform H(-) ion beam extraction in a large negative ion source with a tent-shaped magnetic filter. , 2008, The Review of scientific instruments.

[4]  M. Bacal,et al.  Particle-in-cell modeling of negative-ion transport and extraction processes in a hydrogen negative-ion source , 2006 .

[5]  P. McNeely,et al.  Neutral depletion in an H− source operated at high RF power and low input gas flow , 2011 .

[6]  C. Martens,et al.  Overview of the RF source development programme at IPP Garching , 2006 .

[7]  C. Martens,et al.  Development of a RF-driven ion source for the ITER NBI system , 2009 .

[8]  B. Heinemann,et al.  Design of the half-size ITER neutral beam source for the test facility ELISE , 2009 .

[9]  B. Heinemann,et al.  Negative ion RF sources for ITER NBI: status of the development and recent achievements , 2007 .

[10]  Yasuhiko Takeiri,et al.  Negative ion source development for fusion application (invited). , 2010, The Review of scientific instruments.

[11]  O. Kaneko,et al.  Improvement of the large current negative hydrogen ion source for neutral injection in the large helical device , 1995 .

[12]  Keishi Sakamoto,et al.  Improvement of beam uniformity by magnetic filter optimization in a Cs-seeded large negative-ion source , 2006 .

[13]  Caesium influence on plasma parameters and source performance during conditioning of the ITER neutral beam injector negative ion source , 2011 .

[14]  C. Martens,et al.  Progress of the development of the IPP RF negative ion source for the ITER neutral beam system , 2007 .

[15]  R. Schneider,et al.  Modeling of a negative ion source. III. Two-dimensional structure of the extraction region , 2010 .

[16]  K. Tarnev,et al.  3D model of the magnetic filter region in tandem plasma sources , 2010 .

[17]  B. Heinemann,et al.  Detailed design of the RF source for the 1 MV neutral beam test facility , 2009 .

[18]  R. Gutser,et al.  Negative hydrogen ion transport in RF-driven ion sources for ITER NBI , 2009 .

[19]  C. Martens,et al.  Physical performance analysis and progress of the development of the negative ion RF source for the ITER NBI system , 2009 .

[20]  A. Hatayama,et al.  Numerical analysis of the spatial nonuniformity in a Cs-seeded H - ion source , 2006 .

[21]  A. Holmes ELECTRON COOLING IN MAGNETIC MULTIPOLE ARC DISCHARGES , 1982 .