Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor

In this study, we developed a novel heart rate (HR) monitoring approach in which we measure the pressure variance of the surface of the ear canal. A scissor-shaped apparatus equipped with a piezoelectric film sensor and a hardware circuit module was designed for high wearability and to obtain stable measurement. In the proposed device, the film sensor converts in-ear pulse waves (EPW) into electrical current, and the circuit module enhances the EPW and suppresses noise. A real-time algorithm embedded in the circuit module performs morphological conversions to make the EPW more distinct and knowledge-based rules are used to detect EPW peaks. In a clinical experiment conducted using a reference electrocardiogram (ECG) device, EPW and ECG were concurrently recorded from 58 healthy subjects. The EPW intervals between successive peaks and their corresponding ECG intervals were then compared to each other. Promising results were obtained from the samples, specifically, a sensitivity of 97.25%, positive predictive value of 97.17%, and mean absolute difference of 0.62. Thus, highly accurate HR was obtained from in-ear pressure variance. Consequently, we believe that our proposed approach could be used to monitor vital signs and also utilized in diverse applications in the near future.

[1]  J. Sirohi,et al.  Fundamental Understanding of Piezoelectric Strain Sensors , 1999, Smart Structures.

[2]  Steffen Leonhardt,et al.  Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep , 2013, IEEE Journal of Translational Engineering in Health and Medicine.

[3]  Patrick E. McSharry,et al.  Advanced Methods And Tools for ECG Data Analysis , 2006 .

[4]  Dae-Geun Jang,et al.  Framework for Automatic Delineation of Second Derivative of Photoplethysmogram: A Knowledge-based Approach , 2014 .

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  B. Norrving,et al.  Global atlas on cardiovascular disease prevention and control. , 2011 .

[7]  N. Westerhof,et al.  Forward and backward waves in the arterial system. , 1972, Cardiovascular research.

[8]  Steffen Leonhardt,et al.  A Bendable and Wearable Cardiorespiratory Monitoring Device Fusing Two Noncontact Sensor Principles , 2014, IEEE Journal of Biomedical and Health Informatics.

[9]  Dae-Geun Jang,et al.  A Real-Time Pulse Peak Detection Algorithm for the Photoplethysmogram , 2014 .

[10]  Alexandros Pantelopoulos,et al.  A survey on wearable biosensor systems for health monitoring , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Roger G. Mark,et al.  An open-source algorithm to detect onset of arterial blood pressure pulses , 2003, Computers in Cardiology, 2003.

[12]  Gari D. Clifford,et al.  ECG Statistics , Noise , Artifacts , and Missing Data , 2006 .

[13]  Na Na,et al.  The Temporal Bone and the Ear , 1949 .

[14]  J. Pépin,et al.  Pulse transit time: an appraisal of potential clinical applications , 1999, Thorax.

[15]  Mathieu Lemay,et al.  Photoplethysmography-based ambulatory heartbeat monitoring embedded into a dedicated bracelet , 2013, Computing in Cardiology 2013.

[16]  Koen D Reesink,et al.  Carotid artery pulse wave time characteristics to quantify ventriculoarterial responses to orthostatic challenge. , 2007, Journal of applied physiology.

[17]  M. O'Rourke,et al.  Pulse wave analysis. , 1996, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[18]  E. J. Manwell The Heart Rate , 1933, The Yale Journal of Biology and Medicine.

[19]  H Harry Asada,et al.  Mobile monitoring with wearable photoplethysmographic biosensors. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[20]  Michael F. O'Rourke,et al.  Time domain analysis of the arterial pulse in clinical medicine , 2009, Medical & Biological Engineering & Computing.

[21]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[22]  A Murray,et al.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes , 2002, Journal of Human Hypertension.

[23]  Mirza Mansoor Baig,et al.  A comprehensive survey of wearable and wireless ECG monitoring systems for older adults , 2013, Medical & Biological Engineering & Computing.

[24]  Stéphane Cook,et al.  High heart rate: a cardiovascular risk factor? , 2006, European heart journal.

[25]  Jean-Yves Fourniols,et al.  Smart wearable systems: Current status and future challenges , 2012, Artif. Intell. Medicine.

[26]  Christophe Sarraf,et al.  Dynamic Pressure Calibration , 2013 .

[27]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[28]  D. Altman,et al.  Applying the right statistics: analyses of measurement studies , 2003, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[29]  W. Nichols,et al.  Pulse Wave Analysis of the Aortic Pressure Waveform in Severe Left Ventricular Systolic Dysfunction , 2010, Circulation. Heart failure.

[30]  Motoaki Sugawara,et al.  A new noninvasive measurement system for wave intensity: evaluation of carotid arterial wave intensity and reproducibility , 2002, Heart and Vessels.