Mapping the Stability Diagram of a Quadrupole Mass Spectrometer with a Static Transverse Magnetic Field Applied

AbstractPrevious experimental and theoretical work identified that the application of a static magnetic (B) field can improve the resolution of a quadrupole mass spectrometer (QMS) and this simple method of performance enhancement offers advantages for field deployment. Presented here are further data showing the effect of the transverse magnetic field upon the QMS performance. For the first time, the asymmetry in QMS operation with Bx and By is considered and explained in terms of operation in the fourth quadrant of the stability diagram. The results may be explained by considering the additional Lorentz force (v x B) experienced by the ion trajectories in each case. Using our numerical approach, we model not only the individual ion trajectories for a transverse B field applied in x and y but also the mass spectra and the effect of the magnetic field upon the stability diagram. Our theoretical findings, confirmed by experiment, show an improvement in resolution and ion transmission by application of magnetic field for certain operating conditions. Figureᅟ

[1]  T. J. Hogan,et al.  Effects of Mechanical Tolerances on QMF Performance for Operation in the Third Stability Zone , 2010, IEEE Transactions on Instrumentation and Measurement.

[2]  D. J. Douglas Linear quadrupoles in mass spectrometry. , 2009, Mass spectrometry reviews.

[3]  E. Mathieu Mémoire sur le mouvement vibratoire d'une membrane de forme elliptique. , 1868 .

[4]  R. Cooks,et al.  Quadrupole ion trap mass spectrometry , 1990 .

[5]  R. March,et al.  Quadrupole ion trap mass spectrometry , 2005 .

[6]  R. March,et al.  Quadrupole Ion Trap Mass Spectrometry: March/Quadrupole Ion Trap Mass Spectrometry , 2005 .

[7]  S. Maher,et al.  A Method of Computing Accurate 3D Fields of a Quadrupole Mass Filter and Their Use for Prediction of Filter Behavior , 2012, Journal of The American Society for Mass Spectrometry.

[8]  W. Paul,et al.  Notizen: Ein neues Massenspektrometer ohne Magnetfeld , 1953 .

[9]  Stephen Taylor,et al.  Factors Influencing the QMF Resolution for Operation in Stability Zones 1 and 3 , 2012, Journal of The American Society for Mass Spectrometry.

[10]  P. Dawson Quadrupole mass spectrometry and its applications , 1976 .

[11]  P. Traldi,et al.  Mapping the stability diagram of a digital ion trap (DIT) mass spectrometer varying the duty cycle of the trapping rectangular waveform , 2008, Journal of the American Society for Mass Spectrometry.

[12]  R. Cooks,et al.  A miniature cylindrical quadrupole ion trap:  simulation and experiment. , 1998, Analytical Chemistry.

[13]  Stephen Taylor,et al.  Effect of an axial magnetic field on the performance of a quadrupole mass spectrometer , 2010, Journal of the American Society for Mass Spectrometry.

[14]  R. Yost,et al.  The stretched quadrupole ion trap: Implications for the Mathieu au and qu parameters and experimental mapping of the stability diagram , 1992 .

[15]  J. H. Leck,et al.  Detailed simulation of mass spectra for quadrupole mass spectrometer systems , 2000 .

[16]  Stephen Taylor,et al.  Ion trajectories in quadrupole mass spectrometer with a static transverse magnetic field applied to mass filter , 2000 .

[17]  Stephen Taylor,et al.  Prediction of the effects of imperfect construction of a QMS filter. , 2008, Journal of mass spectrometry : JMS.

[18]  Jh Batey,et al.  Quadropole gas analysers , 1987 .