Adsorption of human plasma proteins to modified titanium surfaces.

OBJECTIVES The aim of this study was to examine the effect of modified titanium (Ti) surfaces on the initial events of plasma proteins adsorption. MATERIALS AND METHODS 'Ti disks' with three types of surface modifications were compared: machined, acid-etched and acid-etched and blasted. Physical and chemical characterizations of the surfaces were performed via scanning electron microscopy (SEM), atomic force microscopy (AFM) used for analysis of surface topography, characterization of the titanium oxide (TiO2) layer was carried out by X-ray photoelectron spectroscopy (XPS) and characterization of surface energy by the determination of contact angles. Evaluation of plasma proteins' adsorption to the treated Ti surfaces was performed by mass spectrometry, confocal laser scanning microscopy and XPS. Quantitative proteins' assessment was carried out by enzyme-linked immunosorbent assay. RESULTS SEM images revealed major differences in the topography of the examined surfaces. Acid-etched and blasted Ti surfaces were found to have higher roughness values and a thicker TiO2 layer as compared with acid-etched and machined surfaces. Moreover, acid-etched and blasted surfaces showed high surface area differentiation, pointing to a high increase in the three-dimensional (3D) surface area over the 2D surface area compared with the other surfaces. Adsorption of plasma proteins to the acid-etched and blasted Ti surfaces was both qualitatively and quantitatively more intense compared with the machined and acid-etched surfaces. This was shown for each examined protein, total proteins and by the removal degree of the protein coat. CONCLUSIONS The preferential adsorption of plasma proteins to the acid-etched and blasted Ti surfaces may be explained by its topographical characteristics and by the increase of the 3D surface area of this modified surface.

[1]  P. Somasundaran,et al.  Thermal and chemical modification of titanium-aluminum-vanadium implant materials: effects on surface properties, glycoprotein adsorption, and MG63 cell attachment. , 2004, Biomaterials.

[2]  J. Ong,et al.  Protein adsorption on titanium surfaces and their effect on osteoblast attachment. , 2003, Journal of biomedical materials research. Part A.

[3]  D Kohavi,et al.  Adsorption of human salivary proteins to titanium powder. I. Adsorption of human salivary albumin. , 1995, Biomaterials.

[4]  P. Somasundaran,et al.  Adsorption and dissolution behavior of human plasma fibronectin on thermally and chemically modified titanium dioxide particles. , 2002, Biomaterials.

[5]  M. Sela,et al.  Mechanism of adsorption of human albumin to titanium in vitro. , 1997, Journal of biomedical materials research.

[6]  B D Boyan,et al.  Microrough implant surface topographies increase osteogenesis by reducing osteoclast formation and activity. , 2004, Journal of biomedical materials research. Part A.

[7]  P. Somasundaran,et al.  Surface analysis of human plasma fibronectin adsorbed to commercially pure titanium materials. , 1998, Journal of biomedical materials research.

[8]  D. Steinberg,et al.  alpha-Amylase and salivary albumin adsorption onto titanium, enamel and dentin: an in vivo study. , 1997, Biomaterials.

[9]  J. Gunsolley,et al.  A multi-center study comparing dual acid-etched and machined-surfaced implants in various bone qualities. , 2001, Journal of periodontology.

[10]  Y. Oshida,et al.  Surface characterizations of variously treated titanium materials. , 2001, The International journal of oral & maxillofacial implants.

[11]  H. Nygren,et al.  Implantation of hydrophilic and hydrophobic titanium discs in rat tibia: cellular reactions on the surfaces during the first 3 weeks in bone. , 2004, Biomaterials.

[12]  M. Sela,et al.  Adsorption of salivary proteins onto prosthetic titanium components. , 1995, The Journal of prosthetic dentistry.

[13]  F Rupp,et al.  Roughness induced dynamic changes of wettability of acid etched titanium implant modifications. , 2004, Biomaterials.

[14]  M. Wilm,et al.  Analytical properties of the nanoelectrospray ion source. , 1996, Analytical chemistry.

[15]  U. Joos,et al.  Influence of titanium surfaces on attachment of osteoblast-like cells in vitro. , 2004, Biomaterials.

[16]  J. Ko,et al.  Effects of extracellular matrix constituents on the attachment of human oral epithelial cells at the titanium surface. , 1998, The International journal of oral & maxillofacial implants.

[17]  Antonio Nanci,et al.  Nanotexturing of titanium-based surfaces upregulates expression of bone sialoprotein and osteopontin by cultured osteogenic cells. , 2004, Biomaterials.

[18]  A. V. von Recum,et al.  Effect of Titanium Surface Texture on the Cell-Biomaterial Interface , 2003, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[19]  R. Proctor Fibronectin: a brief overview of its structure, function, and physiology. , 1987, Reviews of infectious diseases.

[20]  A. Pijpers,et al.  On the determination of atomic charge via ESCA including application to organometallics , 1996 .

[21]  G. Daculsi,et al.  Role of fibronectin during biological apatite crystal nucleation: ultrastructural characterization. , 1999, Journal of biomedical materials research.

[22]  J. Amédée,et al.  Effect of surface roughness of the titanium alloy Ti-6Al-4V on human bone marrow cell response and on protein adsorption. , 2001, Biomaterials.

[23]  U. Joos,et al.  Ultrastructural characterization of the implant/bone interface of immediately loaded dental implants. , 2004, Biomaterials.

[24]  W. Stickle,et al.  Handbook of X-Ray Photoelectron Spectroscopy , 1992 .