Achromatic registration of quadrature components of the optical spectrum in spectral domain optical coherence tomography

We have thoroughly investigated the method of simultaneous reception of spectral components with the achromatised quadrature phase shift between two portions of a reference wave, designed for the effective suppression of the 'mirror' artefact in the resulting image obtained by means of spectral domain optical coherence tomography (SD OCT). We have developed and experimentally tested a phase-shifting element consisting of a beam divider, which splits the reference optical beam into the two beams, and of delay lines being individual for each beam, which create a mutual phase difference of π/2 in the double pass of the reference beam. The phase shift achromatism over a wide spectral range is achieved by using in the delay lines the individual elements with different dispersion characteristics. The ranges of admissible adjustment parameters of the achromatised delay line are estimated for exact and inexact conformity of the geometric characteristics of its components to those calculated. A possibility of simultaneous recording of the close-to-quadrature spectral components with a single linear photodetector element is experimentally confirmed. The suppression of the artefact mirror peak in the OCT-signal by an additional 9 dB relative to the level of its suppression is experimentally achieved when the air delay line ismore » used. Two-dimensional images of the surface positioned at an angle to the axis of the probe beam are obtained with the correction of the 'mirror' artefact while maintaining the dynamic range of the image. (laser biophotonics)« less

[1]  Ruikang K. Wang In vivo full range complex Fourier domain optical coherence tomography , 2007 .

[2]  Ruikang K. Wang,et al.  Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography. , 2007, Optics letters.

[3]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.

[4]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[5]  Maciej Wojtkowski,et al.  Complex and Coherence Noise Free Fourier Domain Optical Coherence Tomography , 2008 .

[6]  V. Gelikonov,et al.  Suppression of image artifacts in the spectral-domain optical coherence tomography , 2009 .

[7]  Maciej Wojtkowski,et al.  Complex spectral OCT in human eye imaging in vivo , 2004 .

[8]  Grigory V. Gelikonov,et al.  Single-shot full complex spectrum spectrometer-based OCT with a single-line photodiode array , 2012, Photonics West - Biomedical Optics.

[9]  Dmitry A. Zimnyakov,et al.  Optical tomography of tissues , 2002 .

[10]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[11]  Grigory V. Gelikonov,et al.  Coherent noise compensation in Spectral-Domain optical coherence tomography , 2009 .

[12]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[13]  Zhilin Hu,et al.  Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer. , 2007, Optics letters.

[14]  Maciej Wojtkowski,et al.  Quality improvement for high resolution in vivo images by spectral domain optical coherence tomography with supercontinuum source , 2005 .

[15]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[16]  Adolf Friedrich Fercher,et al.  Ophthalmic Laser Interferometry , 1986, Other Conferences.

[17]  Theo Lasser,et al.  Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution. , 2006, Optics express.

[18]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[19]  Grigory V. Gelikonov,et al.  Linear-wavenumber spectrometer for high-speed spectral-domain optical coherence tomography , 2009 .

[20]  R J Kennedy,et al.  A Refinement of the Michelson-Morley Experiment. , 1926, Proceedings of the National Academy of Sciences of the United States of America.

[21]  Adolf Friedrich Fercher Optical coherence tomography. , 1996 .

[22]  P. A. Shilyagin,et al.  Suppression of image autocorrelation artefacts in spectral domain optical coherence tomography and multiwave digital holography , 2012 .