An MIP-based model for the deployment of fault indicators and sectionalizing switches in distribution networks

Abstract Fault indicators (FIs) and sectionalizing switches (SSs) are of great importance in distribution automation for reliability enhancement and efficiency improvement. However, their types and locations have great effects on the resulting service quality. This paper intends to develop a model for the optimal simultaneous allocation of FIs and SSs in a complex distribution network based on reliability and cost-benefit analyses. Three position matrices are obtained by preprocessing the topology of distribution networks to enable the establishment of the proposed model. Furthermore, a quantification method for the customer interruption duration under different contingencies is constructed to achieve a more precise and practical reliability evaluation. The resultant optimization problem is formulated as a mixed-integer linear programming that can obtain the global optimal solution in a finite number of iterations. An IEEE 33-bus network and a real urban distribution system are used to verify the effectiveness and efficiency of this model. The obtained outcomes show that simultaneously considering the placement of FIs and SSs can expedite the fault location and isolation processes, reduce the overall costs of the system and improve the service reliability.

[1]  Javad Sadeh,et al.  Fault indicator allocation in power distribution network for improving reliability and fault section estimation , 2011, 2011 International Conference on Advanced Power System Automation and Protection.

[2]  D. V. Coury,et al.  Efficient Placement of Fault Indicators in an Actual Distribution System Using Evolutionary Computing , 2012, IEEE Transactions on Power Systems.

[3]  Matti Lehtonen,et al.  Optimal Distribution Network Automation Considering Earth Fault Events , 2015, IEEE Transactions on Smart Grid.

[4]  Chia-Hung Lin,et al.  Optimal Placement of Fault Indicators Using the Immune Algorithm , 2011, IEEE Transactions on Power Systems.

[5]  B. Raison,et al.  Optimization of fault indicators placement with dispersed generation insertion , 2005, IEEE Power Engineering Society General Meeting, 2005.

[6]  P.M.S. Carvalho,et al.  A decomposition approach to optimal remote controlled switch allocation in distribution systems , 2005, IEEE Transactions on Power Delivery.

[7]  Mohamed A. El-Sharkawi,et al.  Modern heuristic optimization techniques :: theory and applications to power systems , 2008 .

[8]  Amir Safdarian,et al.  Deployment of Fault Indicator in Distribution Networks: A MIP-Based Approach , 2018, IEEE Transactions on Smart Grid.

[9]  Gregory Levitin,et al.  Optimal sectionalizer allocation in electric distribution systems by genetic algorithm , 1994 .

[10]  Hamid Lesani,et al.  Fault Indicator Deployment in Distribution Systems Considering Available Control and Protection Devices: A Multi-Objective Formulation Approach , 2014, IEEE Transactions on Power Systems.

[11]  Felix F. Wu,et al.  Network reconfiguration in distribution systems for loss reduction and load balancing , 1989 .

[12]  Amir Safdarian,et al.  Optimal Placement of Sectionalizing Switch Considering Switch Malfunction Probability , 2019, IEEE Transactions on Smart Grid.

[13]  Jen-Hao Teng,et al.  Automatic and Fast Faulted Line-Section Location Method for Distribution Systems Based on Fault Indicators , 2014, IEEE Transactions on Power Systems.

[14]  Jose Roberto Bezerra,et al.  Multiobjective Optimization Algorithm for Switch Placement in Radial Power Distribution Networks , 2015, IEEE Transactions on Power Delivery.

[15]  Chung-Sheng Li,et al.  Optimal placement of line switches for distribution automation systems using immune algorithm , 2006, IEEE Transactions on Power Systems.

[16]  H Lee Willis,et al.  Power distribution planning reference book , 2000 .

[17]  Christiano Lyra,et al.  Switch Allocation Problems in Power Distribution Systems , 2015, IEEE Transactions on Power Systems.

[18]  Roy Billinton,et al.  Optimal switching device placement in radial distribution systems , 1996 .

[19]  Alireza Fereidunian,et al.  A joint automatic and manual switch placement within distribution systems considering operational probabilities of control sequences , 2015 .

[20]  Juan Camilo Lopez,et al.  Optimisation-based switch allocation to improve energy losses and service restoration in radial electrical distribution systems , 2016 .

[21]  Roy Billinton,et al.  Distribution system reliability indices , 1989 .

[22]  Yin Xu,et al.  Placement of Remote-Controlled Switches to Enhance Distribution System Restoration Capability , 2016, IEEE Transactions on Power Systems.

[23]  James A. Momoh,et al.  Electric Power Distribution, Automation, Protection, and Control , 2007 .

[24]  Amir Safdarian,et al.  Simultaneous Placement of Fault Indicator and Sectionalizing Switch in Distribution Networks , 2019, IEEE Transactions on Smart Grid.

[25]  João P. S. Catalão,et al.  Reliability Optimization of Automated Distribution Networks With Probability Customer Interruption Cost Model in the Presence of DG Units , 2017, IEEE Transactions on Smart Grid.

[26]  C. Singh,et al.  Ant Colony Optimization-Based Method for Placement of Sectionalizing Switches in Distribution Networks Using a Fuzzy Multiobjective Approach , 2009, IEEE Transactions on Power Delivery.

[27]  Visvakumar Aravinthan,et al.  Fault Detector and Switch Placement in Cyber-Enabled Power Distribution Network , 2018, IEEE Transactions on Smart Grid.

[28]  R. Billinton,et al.  Approximate methods for event-based customer interruption cost evaluation , 2005, IEEE Transactions on Power Systems.